T. Maciołek, M. Lewandowski, A. Szeląg, M. Steczek
{"title":"3kv直流牵引系统接触间隙对车辆供电条件及接触网导线磨损的影响","authors":"T. Maciołek, M. Lewandowski, A. Szeląg, M. Steczek","doi":"10.24425/BPASTS.2020.133373","DOIUrl":null,"url":null,"abstract":"Short-term contact losses between a pantograph and a contact wire are not included in the standards nor are they taken into account in evaluating pantograph-contact wire interaction. These contact losses, however, accelerate wear and tear as well as disturb operation of vehicles’ drive systems. The article presents the effects of short-term contact breaks as well as an analysis of impact of contact breakages on a vehicle’s current at 3 kV DC power supply. Results of voltage and current oscillations measured in real conditions when pantograph of a DC driven chopper vehicle was running under isolators were presented. Then a simulation model of a vehicles with ac motors and voltage inverters was derived to undertake simulation experiments verifying operation of such a vehicle in condition similar to those measured in real condition.","PeriodicalId":55299,"journal":{"name":"Bulletin of the Polish Academy of Sciences-Technical Sciences","volume":"689 1","pages":""},"PeriodicalIF":1.2000,"publicationDate":"2023-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Influence of contact gaps on the conditions of vehicles supply and wear and tear of catenary wires in a 3 kV DC traction system\",\"authors\":\"T. Maciołek, M. Lewandowski, A. Szeląg, M. Steczek\",\"doi\":\"10.24425/BPASTS.2020.133373\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Short-term contact losses between a pantograph and a contact wire are not included in the standards nor are they taken into account in evaluating pantograph-contact wire interaction. These contact losses, however, accelerate wear and tear as well as disturb operation of vehicles’ drive systems. The article presents the effects of short-term contact breaks as well as an analysis of impact of contact breakages on a vehicle’s current at 3 kV DC power supply. Results of voltage and current oscillations measured in real conditions when pantograph of a DC driven chopper vehicle was running under isolators were presented. Then a simulation model of a vehicles with ac motors and voltage inverters was derived to undertake simulation experiments verifying operation of such a vehicle in condition similar to those measured in real condition.\",\"PeriodicalId\":55299,\"journal\":{\"name\":\"Bulletin of the Polish Academy of Sciences-Technical Sciences\",\"volume\":\"689 1\",\"pages\":\"\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2023-11-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bulletin of the Polish Academy of Sciences-Technical Sciences\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.24425/BPASTS.2020.133373\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin of the Polish Academy of Sciences-Technical Sciences","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.24425/BPASTS.2020.133373","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
Influence of contact gaps on the conditions of vehicles supply and wear and tear of catenary wires in a 3 kV DC traction system
Short-term contact losses between a pantograph and a contact wire are not included in the standards nor are they taken into account in evaluating pantograph-contact wire interaction. These contact losses, however, accelerate wear and tear as well as disturb operation of vehicles’ drive systems. The article presents the effects of short-term contact breaks as well as an analysis of impact of contact breakages on a vehicle’s current at 3 kV DC power supply. Results of voltage and current oscillations measured in real conditions when pantograph of a DC driven chopper vehicle was running under isolators were presented. Then a simulation model of a vehicles with ac motors and voltage inverters was derived to undertake simulation experiments verifying operation of such a vehicle in condition similar to those measured in real condition.
期刊介绍:
The Bulletin of the Polish Academy of Sciences: Technical Sciences is published bimonthly by the Division IV Engineering Sciences of the Polish Academy of Sciences, since the beginning of the existence of the PAS in 1952. The journal is peer‐reviewed and is published both in printed and electronic form. It is established for the publication of original high quality papers from multidisciplinary Engineering sciences with the following topics preferred:
Artificial and Computational Intelligence,
Biomedical Engineering and Biotechnology,
Civil Engineering,
Control, Informatics and Robotics,
Electronics, Telecommunication and Optoelectronics,
Mechanical and Aeronautical Engineering, Thermodynamics,
Material Science and Nanotechnology,
Power Systems and Power Electronics.