{"title":"污染物对矿物油和棕榈油分解特性的影响","authors":"S. Maneerot, N. Pattanadech","doi":"10.1109/CMD.2018.8535901","DOIUrl":null,"url":null,"abstract":"This paper details an investigation of the effect of contaminant particles at several different temperatures on the 50 Hz AC breakdown voltage of two dielectric liquids - mineral oil and palm oil. The liquids in the test cell used were comprised of various combinations of the following: a) three particle types (cellulose, spherical iron and copper) of approximately 20 μm diameter, b) three contaminant concentrations i.e.0.001% m/V, 0.003% m/V and 0.005% m/V, and c) four liquid temperatures i.e. 25°C, 50°C, 70°C, and 90°C. were investigated with mushroom shaped electrodes in accordance with IEC 60156. The results obtained in this test process showed that the presence of the added particles in the tested dielectric liquids consistently provided a reduction in breakdown voltage, and that the reduction factor varied according to particle type, particle concentration, liquid type, and liquid temperature, and on whether they consisted of cellulose insulation material or copper and iron conducting material summarizing the test results, it was shown that higher contaminant concentration produced lower breakdown voltages, that the addition of copper particles had the most significant effect on reducing breakdown strength, and that the greatest reduction of breakdown strength was measured in the contaminated mineral oil test samples at a test temperature of 70°C.","PeriodicalId":6529,"journal":{"name":"2018 Condition Monitoring and Diagnosis (CMD)","volume":"20 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2018-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of Contaminant on Breakdown Characteristics of Mineral Oil and Palm Oil\",\"authors\":\"S. Maneerot, N. Pattanadech\",\"doi\":\"10.1109/CMD.2018.8535901\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper details an investigation of the effect of contaminant particles at several different temperatures on the 50 Hz AC breakdown voltage of two dielectric liquids - mineral oil and palm oil. The liquids in the test cell used were comprised of various combinations of the following: a) three particle types (cellulose, spherical iron and copper) of approximately 20 μm diameter, b) three contaminant concentrations i.e.0.001% m/V, 0.003% m/V and 0.005% m/V, and c) four liquid temperatures i.e. 25°C, 50°C, 70°C, and 90°C. were investigated with mushroom shaped electrodes in accordance with IEC 60156. The results obtained in this test process showed that the presence of the added particles in the tested dielectric liquids consistently provided a reduction in breakdown voltage, and that the reduction factor varied according to particle type, particle concentration, liquid type, and liquid temperature, and on whether they consisted of cellulose insulation material or copper and iron conducting material summarizing the test results, it was shown that higher contaminant concentration produced lower breakdown voltages, that the addition of copper particles had the most significant effect on reducing breakdown strength, and that the greatest reduction of breakdown strength was measured in the contaminated mineral oil test samples at a test temperature of 70°C.\",\"PeriodicalId\":6529,\"journal\":{\"name\":\"2018 Condition Monitoring and Diagnosis (CMD)\",\"volume\":\"20 1\",\"pages\":\"1-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 Condition Monitoring and Diagnosis (CMD)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CMD.2018.8535901\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 Condition Monitoring and Diagnosis (CMD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CMD.2018.8535901","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文详细研究了几种不同温度下污染物颗粒对矿物油和棕榈油两种介电液体50hz交流击穿电压的影响。所使用的测试池中的液体由以下各种组合组成:a)直径约为20 μm的三种颗粒类型(纤维素,球形铁和铜),b)三种污染物浓度,即0.001% m/V, 0.003% m/V和0.005% m/V,以及c)四种液体温度,即25°c, 50°c, 70°c和90°c。采用符合IEC 60156标准的蘑菇形电极进行研究。实验结果表明,在所测试的介质液体中添加的颗粒一致地降低了击穿电压,并且降低系数根据颗粒类型、颗粒浓度、液体类型和液体温度以及它们是由纤维素绝缘材料还是铜铁导电材料组成而变化。结果表明,污染物浓度越高,击穿电压越低,铜颗粒的加入对击穿强度的降低效果最为显著,在70℃时,污染矿物油试样击穿强度的降低幅度最大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of Contaminant on Breakdown Characteristics of Mineral Oil and Palm Oil
This paper details an investigation of the effect of contaminant particles at several different temperatures on the 50 Hz AC breakdown voltage of two dielectric liquids - mineral oil and palm oil. The liquids in the test cell used were comprised of various combinations of the following: a) three particle types (cellulose, spherical iron and copper) of approximately 20 μm diameter, b) three contaminant concentrations i.e.0.001% m/V, 0.003% m/V and 0.005% m/V, and c) four liquid temperatures i.e. 25°C, 50°C, 70°C, and 90°C. were investigated with mushroom shaped electrodes in accordance with IEC 60156. The results obtained in this test process showed that the presence of the added particles in the tested dielectric liquids consistently provided a reduction in breakdown voltage, and that the reduction factor varied according to particle type, particle concentration, liquid type, and liquid temperature, and on whether they consisted of cellulose insulation material or copper and iron conducting material summarizing the test results, it was shown that higher contaminant concentration produced lower breakdown voltages, that the addition of copper particles had the most significant effect on reducing breakdown strength, and that the greatest reduction of breakdown strength was measured in the contaminated mineral oil test samples at a test temperature of 70°C.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信