用x射线荧光对x射线管中的光子光束进行光谱分析

L. González , P. Morán , V. Delgado , E. Vañó , A. López-Fraguas
{"title":"用x射线荧光对x射线管中的光子光束进行光谱分析","authors":"L. González ,&nbsp;P. Morán ,&nbsp;V. Delgado ,&nbsp;E. Vañó ,&nbsp;A. López-Fraguas","doi":"10.1016/0167-5087(84)90280-1","DOIUrl":null,"url":null,"abstract":"<div><p>A method to perform the measurement of photon beam spectra from X-ray tubes is described. It consists of exciting the fluorescence of elements with their K-binding energies lying within the energetic range of the bremsstrahlung spectrum, using the tube photon beam, and a <sup>241</sup>Am excitation source as a reference, to normalize individual results of each element. According to the numerical treatment described in this article, uncertainties in relative photon flux determinations range from 10% to 2% depending on the photon energies. This method overcomes the difficulties associated with the detection of high photon rates produced by an X-ray tube.</p></div>","PeriodicalId":100972,"journal":{"name":"Nuclear Instruments and Methods in Physics Research","volume":"225 2","pages":"Pages 413-417"},"PeriodicalIF":0.0000,"publicationDate":"1984-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0167-5087(84)90280-1","citationCount":"4","resultStr":"{\"title\":\"Spectrometry of the photon beam from an X-ray tube by X-ray fluorescence\",\"authors\":\"L. González ,&nbsp;P. Morán ,&nbsp;V. Delgado ,&nbsp;E. Vañó ,&nbsp;A. López-Fraguas\",\"doi\":\"10.1016/0167-5087(84)90280-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A method to perform the measurement of photon beam spectra from X-ray tubes is described. It consists of exciting the fluorescence of elements with their K-binding energies lying within the energetic range of the bremsstrahlung spectrum, using the tube photon beam, and a <sup>241</sup>Am excitation source as a reference, to normalize individual results of each element. According to the numerical treatment described in this article, uncertainties in relative photon flux determinations range from 10% to 2% depending on the photon energies. This method overcomes the difficulties associated with the detection of high photon rates produced by an X-ray tube.</p></div>\",\"PeriodicalId\":100972,\"journal\":{\"name\":\"Nuclear Instruments and Methods in Physics Research\",\"volume\":\"225 2\",\"pages\":\"Pages 413-417\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1984-08-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0167-5087(84)90280-1\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nuclear Instruments and Methods in Physics Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/0167508784902801\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Instruments and Methods in Physics Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0167508784902801","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

介绍了一种测量x射线管中光子束光谱的方法。它包括使用管光子束,以241Am激发源为参考,激发k结合能在轫致辐射光谱能量范围内的元素的荧光,使每个元素的单个结果归一化。根据本文描述的数值处理,相对光子通量测定的不确定度根据光子能量的不同在10%到2%之间。这种方法克服了x射线管产生的高光子率检测的困难。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Spectrometry of the photon beam from an X-ray tube by X-ray fluorescence

A method to perform the measurement of photon beam spectra from X-ray tubes is described. It consists of exciting the fluorescence of elements with their K-binding energies lying within the energetic range of the bremsstrahlung spectrum, using the tube photon beam, and a 241Am excitation source as a reference, to normalize individual results of each element. According to the numerical treatment described in this article, uncertainties in relative photon flux determinations range from 10% to 2% depending on the photon energies. This method overcomes the difficulties associated with the detection of high photon rates produced by an X-ray tube.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信