{"title":"GeneMapperTM ID-X Software v1.6与早期版本的一致性研究:峰高检测算法修订对法医STR分型的影响","authors":"Shota Inokuchi, N. Mizuno, K. Sekiguchi","doi":"10.3408/jafst.780","DOIUrl":null,"url":null,"abstract":"not detected by the other version. For the quality assessments by PQV ‰ags, discordance was found in only SPK in Sample-Level Quality Assessments, discordance was found in BIN, PHR, LPH, AN, BD, SPK, and ACC in Marker-Level Quality Assessments. These discordances except for peak area were caused by lower peaks derived from artifact and / or noise. Further, the impact of the version diŠerence on the calculation of the minimum thresholds was evaluated. Although slight diŠerences in detected peak height were observed by the revision of the peak height detection algorithm, the calculated minimum thresholds resulted in the same values.","PeriodicalId":14709,"journal":{"name":"Japanese Journal of Forensic Science and Technology","volume":"49 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Concordance study between GeneMapperTM ID-X Software v1.6 and the earlier version: The impact of revision of peak height detection algorithm on forensic STR typing\",\"authors\":\"Shota Inokuchi, N. Mizuno, K. Sekiguchi\",\"doi\":\"10.3408/jafst.780\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"not detected by the other version. For the quality assessments by PQV ‰ags, discordance was found in only SPK in Sample-Level Quality Assessments, discordance was found in BIN, PHR, LPH, AN, BD, SPK, and ACC in Marker-Level Quality Assessments. These discordances except for peak area were caused by lower peaks derived from artifact and / or noise. Further, the impact of the version diŠerence on the calculation of the minimum thresholds was evaluated. Although slight diŠerences in detected peak height were observed by the revision of the peak height detection algorithm, the calculated minimum thresholds resulted in the same values.\",\"PeriodicalId\":14709,\"journal\":{\"name\":\"Japanese Journal of Forensic Science and Technology\",\"volume\":\"49 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Japanese Journal of Forensic Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3408/jafst.780\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Japanese Journal of Forensic Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3408/jafst.780","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Concordance study between GeneMapperTM ID-X Software v1.6 and the earlier version: The impact of revision of peak height detection algorithm on forensic STR typing
not detected by the other version. For the quality assessments by PQV ‰ags, discordance was found in only SPK in Sample-Level Quality Assessments, discordance was found in BIN, PHR, LPH, AN, BD, SPK, and ACC in Marker-Level Quality Assessments. These discordances except for peak area were caused by lower peaks derived from artifact and / or noise. Further, the impact of the version diŠerence on the calculation of the minimum thresholds was evaluated. Although slight diŠerences in detected peak height were observed by the revision of the peak height detection algorithm, the calculated minimum thresholds resulted in the same values.