313k超声技术对正己烷溶液中1-戊醇与某些有机化合物三元体系的过量性能及理论评价

P. S. S. Ibrahim, J. Jeyakumar, S. Vinayagam
{"title":"313k超声技术对正己烷溶液中1-戊醇与某些有机化合物三元体系的过量性能及理论评价","authors":"P. S. S. Ibrahim, J. Jeyakumar, S. Vinayagam","doi":"10.6000/1929-5030.2021.10.01","DOIUrl":null,"url":null,"abstract":": The parameters like density( ρ ), ultrasonic velocity (U), and viscosity ( η ) were experimentally measured. The excess parameters like adiabatic compressibility, acoustic impedance, free volume, free length, internal pressure and ultrasonic velocity in addition to K value were computed from the experimental data. The variation of these parameters at a constant temperature for the three ternary systems, namely OMP + 1-pentanol+n-hexane, N, N-DMF + 1-pentanol+n-hexane, and MMP + 1-pentanol+n-hexane, have been discussed in the light of molecular interaction. Further, certain theoretical studies are validated with respect to experimental velocities, and the Chi-square test for the goodness of fit is also applied to check the validity of such theoretical models.","PeriodicalId":15165,"journal":{"name":"Journal of Applied Solution Chemistry and Modeling","volume":"55 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-04-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Excess Properties and Theoretical Evaluation on Ternary Systems of 1-Pentanol in n-Hexane Solution with some Organic Compounds at 313 K Using Ultrasonic Technique\",\"authors\":\"P. S. S. Ibrahim, J. Jeyakumar, S. Vinayagam\",\"doi\":\"10.6000/1929-5030.2021.10.01\",\"DOIUrl\":null,\"url\":null,\"abstract\":\": The parameters like density( ρ ), ultrasonic velocity (U), and viscosity ( η ) were experimentally measured. The excess parameters like adiabatic compressibility, acoustic impedance, free volume, free length, internal pressure and ultrasonic velocity in addition to K value were computed from the experimental data. The variation of these parameters at a constant temperature for the three ternary systems, namely OMP + 1-pentanol+n-hexane, N, N-DMF + 1-pentanol+n-hexane, and MMP + 1-pentanol+n-hexane, have been discussed in the light of molecular interaction. Further, certain theoretical studies are validated with respect to experimental velocities, and the Chi-square test for the goodness of fit is also applied to check the validity of such theoretical models.\",\"PeriodicalId\":15165,\"journal\":{\"name\":\"Journal of Applied Solution Chemistry and Modeling\",\"volume\":\"55 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-04-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Applied Solution Chemistry and Modeling\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.6000/1929-5030.2021.10.01\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Solution Chemistry and Modeling","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.6000/1929-5030.2021.10.01","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

实验测量了密度(ρ)、超声速度(U)、粘度(η)等参数。根据实验数据计算了除K值外的绝热压缩率、声阻抗、自由体积、自由长度、内压、超声速度等多余参数。本文从分子相互作用的角度讨论了OMP + 1-戊醇+正己烷、N, N- dmf + 1-戊醇+正己烷和MMP + 1-戊醇+正己烷这三个三元体系在恒温下这些参数的变化。进一步,针对实验速度对某些理论研究进行了验证,并采用卡方拟合优度检验来检验这些理论模型的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Excess Properties and Theoretical Evaluation on Ternary Systems of 1-Pentanol in n-Hexane Solution with some Organic Compounds at 313 K Using Ultrasonic Technique
: The parameters like density( ρ ), ultrasonic velocity (U), and viscosity ( η ) were experimentally measured. The excess parameters like adiabatic compressibility, acoustic impedance, free volume, free length, internal pressure and ultrasonic velocity in addition to K value were computed from the experimental data. The variation of these parameters at a constant temperature for the three ternary systems, namely OMP + 1-pentanol+n-hexane, N, N-DMF + 1-pentanol+n-hexane, and MMP + 1-pentanol+n-hexane, have been discussed in the light of molecular interaction. Further, certain theoretical studies are validated with respect to experimental velocities, and the Chi-square test for the goodness of fit is also applied to check the validity of such theoretical models.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信