并网双馈感应发电机的仿真与实验分析

Gu Jiayang, Yuhe Xiao, Wu Tao, Chang Xianrong, Liu Shanying, L. Hui, Sun Yu
{"title":"并网双馈感应发电机的仿真与实验分析","authors":"Gu Jiayang, Yuhe Xiao, Wu Tao, Chang Xianrong, Liu Shanying, L. Hui, Sun Yu","doi":"10.1109/ICECE.2010.1356","DOIUrl":null,"url":null,"abstract":"With the increase of wind generation penetration in power systems, it becomes more and more important to study its impact on power systems characteristics. The accurate dynamic modeling of wind plants is critical for the grid planning and operating studies. The field test of a three phase short circuit fault at a 35kV busbar in a wind farm in Zhangjiakou Area was performed and a series of corresponding measurements were carried out. A variable speed doubly fed induction generator (DFIG) model in Power System Analysis Software Package (PSASP) is validated and parameters in the models are adjusted by comparing with the results from the field test. Based on the well adjusted parameters of the DFIG model, simulation result shows a better agreement with the field test, and the model has been verified. The reasons for the mismatch between the simulation and the field test results have also been analyzed in the paper. The study contributes to analyzing the impact of grid-connected DFIG on transient stability of the power system.","PeriodicalId":6419,"journal":{"name":"2010 International Conference on Electrical and Control Engineering","volume":"57 1","pages":"5583-5586"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Simulation and Experimental Analysis of Grid-Connected Doubly-Fed Induction Generators\",\"authors\":\"Gu Jiayang, Yuhe Xiao, Wu Tao, Chang Xianrong, Liu Shanying, L. Hui, Sun Yu\",\"doi\":\"10.1109/ICECE.2010.1356\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With the increase of wind generation penetration in power systems, it becomes more and more important to study its impact on power systems characteristics. The accurate dynamic modeling of wind plants is critical for the grid planning and operating studies. The field test of a three phase short circuit fault at a 35kV busbar in a wind farm in Zhangjiakou Area was performed and a series of corresponding measurements were carried out. A variable speed doubly fed induction generator (DFIG) model in Power System Analysis Software Package (PSASP) is validated and parameters in the models are adjusted by comparing with the results from the field test. Based on the well adjusted parameters of the DFIG model, simulation result shows a better agreement with the field test, and the model has been verified. The reasons for the mismatch between the simulation and the field test results have also been analyzed in the paper. The study contributes to analyzing the impact of grid-connected DFIG on transient stability of the power system.\",\"PeriodicalId\":6419,\"journal\":{\"name\":\"2010 International Conference on Electrical and Control Engineering\",\"volume\":\"57 1\",\"pages\":\"5583-5586\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-06-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 International Conference on Electrical and Control Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICECE.2010.1356\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 International Conference on Electrical and Control Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICECE.2010.1356","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

随着风力发电在电力系统中的渗透率不断提高,研究其对电力系统特性的影响变得越来越重要。准确的风电场动态建模对电网规划和运行研究至关重要。对张家口地区某风电场35kV母线三相短路故障进行了现场试验,并进行了一系列相应的测量。对电力系统分析软件包(PSASP)中的变速双馈感应发电机(DFIG)模型进行了验证,并与现场试验结果进行了比较,对模型参数进行了调整。在DFIG模型参数调整良好的基础上,仿真结果与现场试验吻合较好,并对模型进行了验证。本文还对模拟结果与现场试验结果不匹配的原因进行了分析。该研究有助于分析并网DFIG对电力系统暂态稳定的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Simulation and Experimental Analysis of Grid-Connected Doubly-Fed Induction Generators
With the increase of wind generation penetration in power systems, it becomes more and more important to study its impact on power systems characteristics. The accurate dynamic modeling of wind plants is critical for the grid planning and operating studies. The field test of a three phase short circuit fault at a 35kV busbar in a wind farm in Zhangjiakou Area was performed and a series of corresponding measurements were carried out. A variable speed doubly fed induction generator (DFIG) model in Power System Analysis Software Package (PSASP) is validated and parameters in the models are adjusted by comparing with the results from the field test. Based on the well adjusted parameters of the DFIG model, simulation result shows a better agreement with the field test, and the model has been verified. The reasons for the mismatch between the simulation and the field test results have also been analyzed in the paper. The study contributes to analyzing the impact of grid-connected DFIG on transient stability of the power system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信