F. Sauser, Chunyan Li, R. Azizkhan, C. Ahn, I. Papautsky
{"title":"新生儿护理用压力微传感导管","authors":"F. Sauser, Chunyan Li, R. Azizkhan, C. Ahn, I. Papautsky","doi":"10.1109/ICSENS.2004.1426466","DOIUrl":null,"url":null,"abstract":"A pressure microsensing catheter for neonatal care has been developed to measure intravascular blood pressure. The design uses polymer flip-chip bonding on a flexible Kapton film for mounting silicon pressure microsensors into the 5 French dual lumen neonatal catheters (1.67 mm o.d.). While other groups have mounted MEMS sensors on guide wires, our dual-lumen approach permits one lumen of the catheter to contain a packaged pressure sensor while the other lumen retains the catheter functionality. The packaged sensors were characterized in nitrogen and water environments, both statically and dynamically.","PeriodicalId":20476,"journal":{"name":"Proceedings of IEEE Sensors, 2004.","volume":"66 1","pages":"1476-1479 vol.3"},"PeriodicalIF":0.0000,"publicationDate":"2004-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Pressure microsensing catheters for neonatal care\",\"authors\":\"F. Sauser, Chunyan Li, R. Azizkhan, C. Ahn, I. Papautsky\",\"doi\":\"10.1109/ICSENS.2004.1426466\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A pressure microsensing catheter for neonatal care has been developed to measure intravascular blood pressure. The design uses polymer flip-chip bonding on a flexible Kapton film for mounting silicon pressure microsensors into the 5 French dual lumen neonatal catheters (1.67 mm o.d.). While other groups have mounted MEMS sensors on guide wires, our dual-lumen approach permits one lumen of the catheter to contain a packaged pressure sensor while the other lumen retains the catheter functionality. The packaged sensors were characterized in nitrogen and water environments, both statically and dynamically.\",\"PeriodicalId\":20476,\"journal\":{\"name\":\"Proceedings of IEEE Sensors, 2004.\",\"volume\":\"66 1\",\"pages\":\"1476-1479 vol.3\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of IEEE Sensors, 2004.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENS.2004.1426466\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of IEEE Sensors, 2004.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENS.2004.1426466","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A pressure microsensing catheter for neonatal care has been developed to measure intravascular blood pressure. The design uses polymer flip-chip bonding on a flexible Kapton film for mounting silicon pressure microsensors into the 5 French dual lumen neonatal catheters (1.67 mm o.d.). While other groups have mounted MEMS sensors on guide wires, our dual-lumen approach permits one lumen of the catheter to contain a packaged pressure sensor while the other lumen retains the catheter functionality. The packaged sensors were characterized in nitrogen and water environments, both statically and dynamically.