{"title":"保加利亚康复医院伽马剂量率的测量","authors":"D. Djunakova, B. Kunovska, N. Chobanova, J. Djounova, K. Ivanova, Z. Stojanovska","doi":"10.7251/comen2101026d","DOIUrl":null,"url":null,"abstract":"The objective of this study was to evaluate the indoor gamma dose rate in 17 inspected hospitals for rehabilitation where the radon measurements were conducted and to give a more comprehensive evaluation of the total exposure dose. The gamma dose rate in the air was measured in 355 rooms in 17 inspected hospitals for rehabilitation on the territory of Bulgaria. The maximum parameter value was 0.390 μSv/h and the minimum value was 0.06 μSv/h with the 0.157 μSv/h arithmetic mean (standard deviation - 0.160). The gamma dose rate was within the natural variations of the parameter in buildings. Direct measurements of radon were conducted, and the results ranged from 12 Bq/m3 to 3920 Bq/m3. The relationship between the two parameters was examined. A weak correlation between gamma dose rate and indoor radon concentration was found. The measurement of a gamma dose rate could be a useful parameter for carrying out radon workplace control.","PeriodicalId":10617,"journal":{"name":"Contemporary Materials","volume":"39 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-01-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"MEASUREMENT OF GAMMA DOSE RATE IN HOSPITALS FOR REHABILITATION IN BULGARIA\",\"authors\":\"D. Djunakova, B. Kunovska, N. Chobanova, J. Djounova, K. Ivanova, Z. Stojanovska\",\"doi\":\"10.7251/comen2101026d\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The objective of this study was to evaluate the indoor gamma dose rate in 17 inspected hospitals for rehabilitation where the radon measurements were conducted and to give a more comprehensive evaluation of the total exposure dose. The gamma dose rate in the air was measured in 355 rooms in 17 inspected hospitals for rehabilitation on the territory of Bulgaria. The maximum parameter value was 0.390 μSv/h and the minimum value was 0.06 μSv/h with the 0.157 μSv/h arithmetic mean (standard deviation - 0.160). The gamma dose rate was within the natural variations of the parameter in buildings. Direct measurements of radon were conducted, and the results ranged from 12 Bq/m3 to 3920 Bq/m3. The relationship between the two parameters was examined. A weak correlation between gamma dose rate and indoor radon concentration was found. The measurement of a gamma dose rate could be a useful parameter for carrying out radon workplace control.\",\"PeriodicalId\":10617,\"journal\":{\"name\":\"Contemporary Materials\",\"volume\":\"39 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Contemporary Materials\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.7251/comen2101026d\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Contemporary Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7251/comen2101026d","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究的目的是评价17所接受检查的康复医院进行氡测量的室内伽马剂量率,并对总照射剂量作出更全面的评价。在保加利亚境内被视察的17家康复医院的355个房间中测量了空气中的伽马剂量率。参数最大值为0.390 μSv/h,最小值为0.06 μSv/h,算术平均值为0.157 μSv/h(标准差为0.160)。伽马剂量率在建筑物参数的自然变化范围内。对氡进行了直接测量,结果为12 Bq/m3 ~ 3920 Bq/m3。考察了这两个参数之间的关系。伽马剂量率与室内氡浓度之间存在弱相关性。伽马剂量率的测量可能是进行氡工作场所控制的有用参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
MEASUREMENT OF GAMMA DOSE RATE IN HOSPITALS FOR REHABILITATION IN BULGARIA
The objective of this study was to evaluate the indoor gamma dose rate in 17 inspected hospitals for rehabilitation where the radon measurements were conducted and to give a more comprehensive evaluation of the total exposure dose. The gamma dose rate in the air was measured in 355 rooms in 17 inspected hospitals for rehabilitation on the territory of Bulgaria. The maximum parameter value was 0.390 μSv/h and the minimum value was 0.06 μSv/h with the 0.157 μSv/h arithmetic mean (standard deviation - 0.160). The gamma dose rate was within the natural variations of the parameter in buildings. Direct measurements of radon were conducted, and the results ranged from 12 Bq/m3 to 3920 Bq/m3. The relationship between the two parameters was examined. A weak correlation between gamma dose rate and indoor radon concentration was found. The measurement of a gamma dose rate could be a useful parameter for carrying out radon workplace control.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信