CAD-CAM技术制备氧化锆和聚醚醚酮嵌体固位义齿的边缘配合评价

Jannat Hassan, A. Ahmed, Walaa El-Mekkawi
{"title":"CAD-CAM技术制备氧化锆和聚醚醚酮嵌体固位义齿的边缘配合评价","authors":"Jannat Hassan, A. Ahmed, Walaa El-Mekkawi","doi":"10.21608/adjg.2021.48254.1318","DOIUrl":null,"url":null,"abstract":"Purpose: The purpose of this study was to compare marginal fit of Zirconia and Polyetheretherketone (PEEK) inlay retained fixed partial dentures (IRFPD) fabricated by using a computer-aided design and computer-aided manufacturing (CAD-CAM) system. Materials and Methods: Sound Mandibular second premolar and mandibular second molar were selected to simulate a clinical situation of a missing mandibular first molar and embedded in an epoxy resin (master model). Both teeth received a standard preparation of IRFPD with respect to all-ceramic preparation design parameters. The master model was duplicated into 18 epoxy resin models for standardization during testing procedure, and 18 IRFPDs were fabricated with CAD-CAM system and divided into 2 groups according to materials type (n=9); Group 1: 3-mol yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP), Group 2: PEEK. Marginal Discrepancy of all bridges was tested before and after cementation with RelyX U200 self-adhesive resin cement (SARC) by using an optical digital microscope with the aid of an image analysis system. Results: Significantly lower marginal gap values were obtained in Zirconia group before and after cementation in comparison to PEEK group. There was also a significant increase of marginal gap after cementation in both groups, with higher mean in Zirconia group. Conclusion: The margins of IRFPDs performed well with recommended bonding protocols for both materials and present a viable treatment option for replacing a missing single posterior tooth. Both materials presented clinically accepted results of marginal discrepancy less than 120 μm. Further studies simulating clinical conditions are needed to understand how they perform in function. Codex : 03/22.01 azhardentj@azhar.edu.eg http://adjg.journals.ekb.eg DOI: 10.21608/adjg.2021.48254.1318 Restorative Dentistry (Removable Prosthodontics, Fixed Prosthodontics, Endodontics, Dental Biomaterials, Operative Dentistry)","PeriodicalId":7493,"journal":{"name":"Al-Azhar Dental Journal for Girls","volume":"80 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Marginal Fit Evaluation of Zirconia and Polyetheretherketone Inlay Retained Fixed Partial Dentures Fabricated with CAD-CAM\",\"authors\":\"Jannat Hassan, A. Ahmed, Walaa El-Mekkawi\",\"doi\":\"10.21608/adjg.2021.48254.1318\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose: The purpose of this study was to compare marginal fit of Zirconia and Polyetheretherketone (PEEK) inlay retained fixed partial dentures (IRFPD) fabricated by using a computer-aided design and computer-aided manufacturing (CAD-CAM) system. Materials and Methods: Sound Mandibular second premolar and mandibular second molar were selected to simulate a clinical situation of a missing mandibular first molar and embedded in an epoxy resin (master model). Both teeth received a standard preparation of IRFPD with respect to all-ceramic preparation design parameters. The master model was duplicated into 18 epoxy resin models for standardization during testing procedure, and 18 IRFPDs were fabricated with CAD-CAM system and divided into 2 groups according to materials type (n=9); Group 1: 3-mol yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP), Group 2: PEEK. Marginal Discrepancy of all bridges was tested before and after cementation with RelyX U200 self-adhesive resin cement (SARC) by using an optical digital microscope with the aid of an image analysis system. Results: Significantly lower marginal gap values were obtained in Zirconia group before and after cementation in comparison to PEEK group. There was also a significant increase of marginal gap after cementation in both groups, with higher mean in Zirconia group. Conclusion: The margins of IRFPDs performed well with recommended bonding protocols for both materials and present a viable treatment option for replacing a missing single posterior tooth. Both materials presented clinically accepted results of marginal discrepancy less than 120 μm. Further studies simulating clinical conditions are needed to understand how they perform in function. Codex : 03/22.01 azhardentj@azhar.edu.eg http://adjg.journals.ekb.eg DOI: 10.21608/adjg.2021.48254.1318 Restorative Dentistry (Removable Prosthodontics, Fixed Prosthodontics, Endodontics, Dental Biomaterials, Operative Dentistry)\",\"PeriodicalId\":7493,\"journal\":{\"name\":\"Al-Azhar Dental Journal for Girls\",\"volume\":\"80 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Al-Azhar Dental Journal for Girls\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21608/adjg.2021.48254.1318\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Al-Azhar Dental Journal for Girls","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/adjg.2021.48254.1318","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

目的:比较计算机辅助设计和计算机辅助制造(CAD-CAM)系统制作的氧化锆和聚醚醚酮(PEEK)嵌体固位固定局部义齿(IRFPD)的边缘配合。材料与方法:选择完好的下颌第二前磨牙和下颌第二磨牙,模拟下颌第一磨牙缺失的临床情况,并将其嵌入环氧树脂(主模型)中。根据全陶瓷制备设计参数,两颗牙均接受了标准的IRFPD制备。在测试过程中,将主模型复制成18个环氧树脂模型进行标准化,并使用CAD-CAM系统制作18个irfpd,根据材料类型分为2组(n=9);第1组:3-mol钇稳定的四方氧化锆多晶(3Y-TZP),第2组:PEEK。采用光学数码显微镜,结合图像分析系统,对所有桥梁用RelyX U200自粘树脂水泥(SARC)胶结前后的边缘差异进行了测试。结果:与PEEK组相比,氧化锆组固牙前后的边缘间隙值明显降低。两组固牙后边缘间隙均显著增加,其中氧化锆组的平均值更高。结论:irfpd边缘在两种材料推荐的粘接方案下表现良好,为替代缺失的单颗后牙提供了可行的治疗选择。两种材料的临床可接受结果的边际差异小于120 μm。需要进一步的模拟临床条件的研究来了解它们是如何发挥功能的。法典:03/22.01 azhardentj@azhar.edu.eg http://adjg.journals.ekb.eg DOI: 10.21608/adjg.2021.48254.1318修复牙科(可移动修复学,固定修复学,牙髓学,牙科生物材料,牙科手术)
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Marginal Fit Evaluation of Zirconia and Polyetheretherketone Inlay Retained Fixed Partial Dentures Fabricated with CAD-CAM
Purpose: The purpose of this study was to compare marginal fit of Zirconia and Polyetheretherketone (PEEK) inlay retained fixed partial dentures (IRFPD) fabricated by using a computer-aided design and computer-aided manufacturing (CAD-CAM) system. Materials and Methods: Sound Mandibular second premolar and mandibular second molar were selected to simulate a clinical situation of a missing mandibular first molar and embedded in an epoxy resin (master model). Both teeth received a standard preparation of IRFPD with respect to all-ceramic preparation design parameters. The master model was duplicated into 18 epoxy resin models for standardization during testing procedure, and 18 IRFPDs were fabricated with CAD-CAM system and divided into 2 groups according to materials type (n=9); Group 1: 3-mol yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP), Group 2: PEEK. Marginal Discrepancy of all bridges was tested before and after cementation with RelyX U200 self-adhesive resin cement (SARC) by using an optical digital microscope with the aid of an image analysis system. Results: Significantly lower marginal gap values were obtained in Zirconia group before and after cementation in comparison to PEEK group. There was also a significant increase of marginal gap after cementation in both groups, with higher mean in Zirconia group. Conclusion: The margins of IRFPDs performed well with recommended bonding protocols for both materials and present a viable treatment option for replacing a missing single posterior tooth. Both materials presented clinically accepted results of marginal discrepancy less than 120 μm. Further studies simulating clinical conditions are needed to understand how they perform in function. Codex : 03/22.01 azhardentj@azhar.edu.eg http://adjg.journals.ekb.eg DOI: 10.21608/adjg.2021.48254.1318 Restorative Dentistry (Removable Prosthodontics, Fixed Prosthodontics, Endodontics, Dental Biomaterials, Operative Dentistry)
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信