I. Yanishen, R. Kuznetsov, O. Fedotova, A. Pohorila, M. Bohatyrenko
{"title":"固定义齿结构用牙水泥主要性能的比较评价","authors":"I. Yanishen, R. Kuznetsov, O. Fedotova, A. Pohorila, M. Bohatyrenko","doi":"10.35339/ekm.2023.92.1.ykf","DOIUrl":null,"url":null,"abstract":"The study was conducted to compare the main characteristics of dental cements for permanent fixation of fixed dentures. Some materials, formed by the reaction of weak polymeric acids with inorganic glass powder. Dental cements have a number of advantages: due to adhesion, the material \"join\" the surface of the abutment tooth and the inner surface of the artificial structure; some permanent cements slowly release fluoride ions over time to maintain dental health; they do not dissolve in the oral fluid. Despite the advantages, these materials need further improvement in their mechanical performance. Laboratory tests were carried out in the conditions of the accredited in the system of UKR-SEPRO and licensed research laboratory of JSC \"Stoma\". The following basic properties were studied: mixing time (Tm, s), curing time (Tc, s), film thickness (μm), compressive strength (MPa), acid solubility (mm/h), adhesion to metal/dentin (MPa). The process of mixing the components of the \"Compomer\" material is 2.5 s longer than that of \"Ketac Cem\" and 7.7 s longer than that of \"Fuji Plus\". In the case of the \"curing time\" indicator, the \"Fuji Plus\" material is significantly different, with a curing time that is 4.5 s faster than that of \"Ketac Cem\" and half the \"curing time\" compared to \"Compomer\". \"Ketac Cem\" has the lowest \"film thickness\" value – (21.8±0.8) μm, which significantly differs (p≤0.05) from the materials selected for the study. The study of the compression resistance of the cements revealed their full compliance with the standard value according to ISO-9917-1:2007. The acid solubility of the tested cements is at the level of (0.14÷0.29) mm/h. The adhesion index of the tested cements fully meets the requirements of international standards.\n\nKeywords: permanent cement, non-removable denture structures, properties, adhesion, international standards.","PeriodicalId":38819,"journal":{"name":"Tokai Journal of Experimental and Clinical Medicine","volume":"47 22 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparative evaluation of the main properties of dental cements for permanent fixation of non-removable denture structures\",\"authors\":\"I. Yanishen, R. Kuznetsov, O. Fedotova, A. Pohorila, M. Bohatyrenko\",\"doi\":\"10.35339/ekm.2023.92.1.ykf\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The study was conducted to compare the main characteristics of dental cements for permanent fixation of fixed dentures. Some materials, formed by the reaction of weak polymeric acids with inorganic glass powder. Dental cements have a number of advantages: due to adhesion, the material \\\"join\\\" the surface of the abutment tooth and the inner surface of the artificial structure; some permanent cements slowly release fluoride ions over time to maintain dental health; they do not dissolve in the oral fluid. Despite the advantages, these materials need further improvement in their mechanical performance. Laboratory tests were carried out in the conditions of the accredited in the system of UKR-SEPRO and licensed research laboratory of JSC \\\"Stoma\\\". The following basic properties were studied: mixing time (Tm, s), curing time (Tc, s), film thickness (μm), compressive strength (MPa), acid solubility (mm/h), adhesion to metal/dentin (MPa). The process of mixing the components of the \\\"Compomer\\\" material is 2.5 s longer than that of \\\"Ketac Cem\\\" and 7.7 s longer than that of \\\"Fuji Plus\\\". In the case of the \\\"curing time\\\" indicator, the \\\"Fuji Plus\\\" material is significantly different, with a curing time that is 4.5 s faster than that of \\\"Ketac Cem\\\" and half the \\\"curing time\\\" compared to \\\"Compomer\\\". \\\"Ketac Cem\\\" has the lowest \\\"film thickness\\\" value – (21.8±0.8) μm, which significantly differs (p≤0.05) from the materials selected for the study. The study of the compression resistance of the cements revealed their full compliance with the standard value according to ISO-9917-1:2007. The acid solubility of the tested cements is at the level of (0.14÷0.29) mm/h. The adhesion index of the tested cements fully meets the requirements of international standards.\\n\\nKeywords: permanent cement, non-removable denture structures, properties, adhesion, international standards.\",\"PeriodicalId\":38819,\"journal\":{\"name\":\"Tokai Journal of Experimental and Clinical Medicine\",\"volume\":\"47 22 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Tokai Journal of Experimental and Clinical Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.35339/ekm.2023.92.1.ykf\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Tokai Journal of Experimental and Clinical Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35339/ekm.2023.92.1.ykf","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
Comparative evaluation of the main properties of dental cements for permanent fixation of non-removable denture structures
The study was conducted to compare the main characteristics of dental cements for permanent fixation of fixed dentures. Some materials, formed by the reaction of weak polymeric acids with inorganic glass powder. Dental cements have a number of advantages: due to adhesion, the material "join" the surface of the abutment tooth and the inner surface of the artificial structure; some permanent cements slowly release fluoride ions over time to maintain dental health; they do not dissolve in the oral fluid. Despite the advantages, these materials need further improvement in their mechanical performance. Laboratory tests were carried out in the conditions of the accredited in the system of UKR-SEPRO and licensed research laboratory of JSC "Stoma". The following basic properties were studied: mixing time (Tm, s), curing time (Tc, s), film thickness (μm), compressive strength (MPa), acid solubility (mm/h), adhesion to metal/dentin (MPa). The process of mixing the components of the "Compomer" material is 2.5 s longer than that of "Ketac Cem" and 7.7 s longer than that of "Fuji Plus". In the case of the "curing time" indicator, the "Fuji Plus" material is significantly different, with a curing time that is 4.5 s faster than that of "Ketac Cem" and half the "curing time" compared to "Compomer". "Ketac Cem" has the lowest "film thickness" value – (21.8±0.8) μm, which significantly differs (p≤0.05) from the materials selected for the study. The study of the compression resistance of the cements revealed their full compliance with the standard value according to ISO-9917-1:2007. The acid solubility of the tested cements is at the level of (0.14÷0.29) mm/h. The adhesion index of the tested cements fully meets the requirements of international standards.
Keywords: permanent cement, non-removable denture structures, properties, adhesion, international standards.
期刊介绍:
The Tokai Journal of Experimental and Clinical Medicine, also referred to as Tokai Journal, is an official quarterly publication of the Tokai Medical Association. Tokai Journal publishes original articles that deal with issues of clinical, experimental, socioeconomic, cultural and/or historical importance to medical science and related fields. Manuscripts may be submitted as full-length Original Articles or Brief Communications. Tokai Journal also publishes reviews and symposium proceedings. Articles accepted for publication in Tokai Journal cannot be reproduced elsewhere without written permission from the Tokai Medical Association. In addition, Tokai Journal will not be held responsible for the opinions of the authors expressed in the published articles.