{"title":"环CFST短柱环境腐蚀时变可靠度分析","authors":"Yan-lei Wang, Ming-min Cao, Hui-jie Sun","doi":"10.1016/j.pscr.2015.04.002","DOIUrl":null,"url":null,"abstract":"<div><p>Concrete filled steel tubular (CFST) columns subjected to environmental attack can experience changes in resistance that are time-variant. In this study, the axial compressive strength loss in circle CFST stub columns due to corrosion of the outer steel tube is investigated. The assessment of the time-dependent reliability analysis of circular CFST stub columns under environmental corrosion is presented. A probabilistic axial compression model for circular CFST stub columns is developed based on an analytic formula that considers corrosion-related and time-dependent factors. This study involves the formulation of a limit states function, the development of load models, the development of resistance models for corroded circular CFST columns, time-dependent reliability and resistance analysis for a hypothetical stub column. The results of this study can be applied to achieve a better prediction of the service life of deteriorating circular CFST columns and the development of optimal reliability-based maintenance strategies.</p></div>","PeriodicalId":100998,"journal":{"name":"Pacific Science Review","volume":"16 3","pages":"Pages 201-206"},"PeriodicalIF":0.0000,"publicationDate":"2014-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.pscr.2015.04.002","citationCount":"10","resultStr":"{\"title\":\"Time-dependent reliability analysis of circular CFST stub columns under environmental corrosion\",\"authors\":\"Yan-lei Wang, Ming-min Cao, Hui-jie Sun\",\"doi\":\"10.1016/j.pscr.2015.04.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Concrete filled steel tubular (CFST) columns subjected to environmental attack can experience changes in resistance that are time-variant. In this study, the axial compressive strength loss in circle CFST stub columns due to corrosion of the outer steel tube is investigated. The assessment of the time-dependent reliability analysis of circular CFST stub columns under environmental corrosion is presented. A probabilistic axial compression model for circular CFST stub columns is developed based on an analytic formula that considers corrosion-related and time-dependent factors. This study involves the formulation of a limit states function, the development of load models, the development of resistance models for corroded circular CFST columns, time-dependent reliability and resistance analysis for a hypothetical stub column. The results of this study can be applied to achieve a better prediction of the service life of deteriorating circular CFST columns and the development of optimal reliability-based maintenance strategies.</p></div>\",\"PeriodicalId\":100998,\"journal\":{\"name\":\"Pacific Science Review\",\"volume\":\"16 3\",\"pages\":\"Pages 201-206\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.pscr.2015.04.002\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pacific Science Review\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1229545014200015\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pacific Science Review","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1229545014200015","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Time-dependent reliability analysis of circular CFST stub columns under environmental corrosion
Concrete filled steel tubular (CFST) columns subjected to environmental attack can experience changes in resistance that are time-variant. In this study, the axial compressive strength loss in circle CFST stub columns due to corrosion of the outer steel tube is investigated. The assessment of the time-dependent reliability analysis of circular CFST stub columns under environmental corrosion is presented. A probabilistic axial compression model for circular CFST stub columns is developed based on an analytic formula that considers corrosion-related and time-dependent factors. This study involves the formulation of a limit states function, the development of load models, the development of resistance models for corroded circular CFST columns, time-dependent reliability and resistance analysis for a hypothetical stub column. The results of this study can be applied to achieve a better prediction of the service life of deteriorating circular CFST columns and the development of optimal reliability-based maintenance strategies.