{"title":"背景:利用风资料估算尼日利亚中北部空气污染物水平稀释势的研究","authors":"M. S. Shiada, D. T. Ayaakaa, T. T. Bem, S. Ode","doi":"10.9734/jalsi/2023/v26i2600","DOIUrl":null,"url":null,"abstract":"The study gives a background estimate of the dilution potential of air pollutants (SO2, NO2 and CO) in three selected North Central States of Nigeria. The research was carried out using wind impact area diagram, obtained by using standard deviation to calculate  analysis of pollutants and other variables of spread whose concentration were determined downwind. The results indicate that Makurdi and Lafia have varying wind direction persistence (p) approximately 1.0m2 for all the months. This can cause variation in wind directions. It also indicate unstable pattern of wind observation in this cities. For Makurdi, lowest and highest value of potential stands at M (12.15 m2) and (42.5 m2) were observed in April and May accordingly. For Lafia, values obtained by potential impact stands at M (2.20m2) and (67.50 m2) for the months indicated. Finally, Jos has (p) equal to 1.2m2 through all months, showing steady wind compared to two cities of Makurdi and Lafia and the predominant wind direction during the period  of October 2018 to February 2019. Lowest and largest values of dilution potentials M (1.50m2 and 113.37m2) were obtained for February and December of the same year under review. Lowest values of m (dilution potential) indicate lower dilution potentials in these cities which indicate high concentration of inert pollutants while larger value of M predicts high volume of wind speed with a big impact area. The study showed that, dilution potential can be applied in comparing the wind data in line and space. It also portrays that wind impact diagram gives a good representation of wind along with area of high pollutants concentration as compared to wind rose. Finally, the information obtained from the research suggests air quality monitoring stations are required in Makurdi, Lafia and Jos for effective monitoring of air pollutants in these cities.","PeriodicalId":14990,"journal":{"name":"Journal of Applied Life Sciences International","volume":"24 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Background Study on the Estimation of Horizontal Dilution Potential of air Pollutants in North-Central Nigeria, Using Wind Data\",\"authors\":\"M. S. Shiada, D. T. Ayaakaa, T. T. Bem, S. Ode\",\"doi\":\"10.9734/jalsi/2023/v26i2600\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The study gives a background estimate of the dilution potential of air pollutants (SO2, NO2 and CO) in three selected North Central States of Nigeria. The research was carried out using wind impact area diagram, obtained by using standard deviation to calculate  analysis of pollutants and other variables of spread whose concentration were determined downwind. The results indicate that Makurdi and Lafia have varying wind direction persistence (p) approximately 1.0m2 for all the months. This can cause variation in wind directions. It also indicate unstable pattern of wind observation in this cities. For Makurdi, lowest and highest value of potential stands at M (12.15 m2) and (42.5 m2) were observed in April and May accordingly. For Lafia, values obtained by potential impact stands at M (2.20m2) and (67.50 m2) for the months indicated. Finally, Jos has (p) equal to 1.2m2 through all months, showing steady wind compared to two cities of Makurdi and Lafia and the predominant wind direction during the period  of October 2018 to February 2019. Lowest and largest values of dilution potentials M (1.50m2 and 113.37m2) were obtained for February and December of the same year under review. Lowest values of m (dilution potential) indicate lower dilution potentials in these cities which indicate high concentration of inert pollutants while larger value of M predicts high volume of wind speed with a big impact area. The study showed that, dilution potential can be applied in comparing the wind data in line and space. It also portrays that wind impact diagram gives a good representation of wind along with area of high pollutants concentration as compared to wind rose. Finally, the information obtained from the research suggests air quality monitoring stations are required in Makurdi, Lafia and Jos for effective monitoring of air pollutants in these cities.\",\"PeriodicalId\":14990,\"journal\":{\"name\":\"Journal of Applied Life Sciences International\",\"volume\":\"24 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-03-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Applied Life Sciences International\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.9734/jalsi/2023/v26i2600\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Life Sciences International","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9734/jalsi/2023/v26i2600","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

该研究对尼日利亚中北部三个选定州的空气污染物(SO2、NO2和CO)的稀释潜力进行了背景估计。研究使用风向影响面积图,该图通过标准差计算分析污染物和其他分布变量,其浓度在顺风处确定。结果表明,马库尔迪和拉菲亚各月份的风向持续性变化(p)约为1.0m2。这会导致风向的变化。这也表明了该城市的风观测模式不稳定。马库尔迪的潜在林分值在4月和5月分别为M (12.15 m2)和M (42.5 m2)。对于拉菲亚,在指定的月份中,潜在影响的值为M(2.20平方米)和(67.50平方米)。最后,乔斯的(p)在所有月份都等于1.2平方米,与马库尔迪和拉菲亚两个城市以及2018年10月至2019年2月期间的主要风向相比,显示出稳定的风。同年2月和12月稀释势M最小和最大,分别为1.50m2和113.37m2。m(稀释势)值越小,表明这些城市的稀释势越低,表明惰性污染物浓度越高;m值越大,表明风速越大,影响面积越大。研究表明,稀释势可以应用于线上和空间上风资料的比较。它还描绘了风的影响图可以很好地代表风和高污染物浓度区域,而不是风上升。最后,从研究中获得的信息表明,为了有效监测这些城市的空气污染物,马库尔迪、拉菲亚和乔斯需要空气质量监测站。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Background Study on the Estimation of Horizontal Dilution Potential of air Pollutants in North-Central Nigeria, Using Wind Data
The study gives a background estimate of the dilution potential of air pollutants (SO2, NO2 and CO) in three selected North Central States of Nigeria. The research was carried out using wind impact area diagram, obtained by using standard deviation to calculate  analysis of pollutants and other variables of spread whose concentration were determined downwind. The results indicate that Makurdi and Lafia have varying wind direction persistence (p) approximately 1.0m2 for all the months. This can cause variation in wind directions. It also indicate unstable pattern of wind observation in this cities. For Makurdi, lowest and highest value of potential stands at M (12.15 m2) and (42.5 m2) were observed in April and May accordingly. For Lafia, values obtained by potential impact stands at M (2.20m2) and (67.50 m2) for the months indicated. Finally, Jos has (p) equal to 1.2m2 through all months, showing steady wind compared to two cities of Makurdi and Lafia and the predominant wind direction during the period  of October 2018 to February 2019. Lowest and largest values of dilution potentials M (1.50m2 and 113.37m2) were obtained for February and December of the same year under review. Lowest values of m (dilution potential) indicate lower dilution potentials in these cities which indicate high concentration of inert pollutants while larger value of M predicts high volume of wind speed with a big impact area. The study showed that, dilution potential can be applied in comparing the wind data in line and space. It also portrays that wind impact diagram gives a good representation of wind along with area of high pollutants concentration as compared to wind rose. Finally, the information obtained from the research suggests air quality monitoring stations are required in Makurdi, Lafia and Jos for effective monitoring of air pollutants in these cities.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信