尼日利亚东北部乳房x光检查的诊断参考水平

D. Joseph, C. Nzotta, Joseph Dimas Skam, M. Umar, Dambele Y. Musa
{"title":"尼日利亚东北部乳房x光检查的诊断参考水平","authors":"D. Joseph, C. Nzotta, Joseph Dimas Skam, M. Umar, Dambele Y. Musa","doi":"10.4103/ajmhs.ajmhs_43_17","DOIUrl":null,"url":null,"abstract":"Background: Diagnostic reference levels (DRLs) plays an important role in health-care delivery and radiation safety of patients. This study was carried out as part of a comprehensive project to establish DRLs for the radiological examinations for the first time in North Eastern Nigeria. Objective of the Study: The aim is to establish DRL for mammography examination in North Eastern Nigeria and to compare it with other established works. Materials and Methods: This study is a prospective cross-sectional study conducted in two university teaching hospitals in North Eastern Nigeria. Sixty patients were recruited for the study. Thermoluminescent dosimeter (TLD) chips were exposed for craniocaudal (CC) and mediolateral examinations to record the entrance skin dose (ESD). TLD readings were obtained at the Center for Energy Research and Training Zaria, Kaduna State, Nigeria. Dance formula was used to convert ESD to mean glandular dose (MGD). Student's t-test was used to determine the relationship between the mean ESD obtained in the two centers and Pearson's correlation was used to determine the relationship between the MGD and anthropotechnical parameters. Statistical significance was set at P < 0.05. Results: The total MGD for this study was 0.31 ± 0.05 mGy and 0.69 ± 0.11 mGy for CC and mediolateral oblique (MLO), respectively. DRL was 0.63 mGy and 1.04 mGy for CC and MLO, respectively. There was no statistically significant relationship (P > 0.05) between the MGD and anthropotechnical parameters. The DRL in this work were higher when compared with international established work. Conclusion: There is need for optimization of our radiology practice in North Eastern Nigeria and most centers in Nigeria.","PeriodicalId":93249,"journal":{"name":"African journal of medical and health sciences","volume":"263 1","pages":"54 - 59"},"PeriodicalIF":0.0000,"publicationDate":"2018-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Diagnostic reference levels for mammography examinations in North Eastern Nigeria\",\"authors\":\"D. Joseph, C. Nzotta, Joseph Dimas Skam, M. Umar, Dambele Y. Musa\",\"doi\":\"10.4103/ajmhs.ajmhs_43_17\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Diagnostic reference levels (DRLs) plays an important role in health-care delivery and radiation safety of patients. This study was carried out as part of a comprehensive project to establish DRLs for the radiological examinations for the first time in North Eastern Nigeria. Objective of the Study: The aim is to establish DRL for mammography examination in North Eastern Nigeria and to compare it with other established works. Materials and Methods: This study is a prospective cross-sectional study conducted in two university teaching hospitals in North Eastern Nigeria. Sixty patients were recruited for the study. Thermoluminescent dosimeter (TLD) chips were exposed for craniocaudal (CC) and mediolateral examinations to record the entrance skin dose (ESD). TLD readings were obtained at the Center for Energy Research and Training Zaria, Kaduna State, Nigeria. Dance formula was used to convert ESD to mean glandular dose (MGD). Student's t-test was used to determine the relationship between the mean ESD obtained in the two centers and Pearson's correlation was used to determine the relationship between the MGD and anthropotechnical parameters. Statistical significance was set at P < 0.05. Results: The total MGD for this study was 0.31 ± 0.05 mGy and 0.69 ± 0.11 mGy for CC and mediolateral oblique (MLO), respectively. DRL was 0.63 mGy and 1.04 mGy for CC and MLO, respectively. There was no statistically significant relationship (P > 0.05) between the MGD and anthropotechnical parameters. The DRL in this work were higher when compared with international established work. Conclusion: There is need for optimization of our radiology practice in North Eastern Nigeria and most centers in Nigeria.\",\"PeriodicalId\":93249,\"journal\":{\"name\":\"African journal of medical and health sciences\",\"volume\":\"263 1\",\"pages\":\"54 - 59\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-06-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"African journal of medical and health sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/ajmhs.ajmhs_43_17\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"African journal of medical and health sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/ajmhs.ajmhs_43_17","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

背景:诊断参考水平(DRLs)在医疗服务提供和患者的辐射安全中起着重要作用。这项研究是作为一个综合项目的一部分进行的,该项目旨在首次在尼日利亚东北部建立放射检查的详细记录。研究目的:目的是建立尼日利亚东北部乳房x线检查的DRL,并将其与其他已建立的工作进行比较。材料与方法:本研究是在尼日利亚东北部两所大学教学医院进行的前瞻性横断面研究。这项研究招募了60名患者。热释光剂量计(TLD)芯片暴露于颅侧(CC)和中外侧检查,记录入口皮肤剂量(ESD)。TLD读数在尼日利亚卡杜纳州扎里亚能源研究和培训中心获得。采用Dance公式将ESD换算为平均腺剂量(MGD)。采用学生t检验确定两个中心平均ESD之间的关系,采用Pearson相关法确定MGD与人体技术参数之间的关系。差异有统计学意义,P < 0.05。结果:本研究CC和MLO的总MGD分别为0.31±0.05 mGy和0.69±0.11 mGy。CC和MLO的DRL分别为0.63 mGy和1.04 mGy。MGD与人体技术参数之间无统计学意义(P > 0.05)。与国际上已有的研究相比,本研究的DRL较高。结论:我们在尼日利亚东北部和尼日利亚大部分中心的放射学实践需要优化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Diagnostic reference levels for mammography examinations in North Eastern Nigeria
Background: Diagnostic reference levels (DRLs) plays an important role in health-care delivery and radiation safety of patients. This study was carried out as part of a comprehensive project to establish DRLs for the radiological examinations for the first time in North Eastern Nigeria. Objective of the Study: The aim is to establish DRL for mammography examination in North Eastern Nigeria and to compare it with other established works. Materials and Methods: This study is a prospective cross-sectional study conducted in two university teaching hospitals in North Eastern Nigeria. Sixty patients were recruited for the study. Thermoluminescent dosimeter (TLD) chips were exposed for craniocaudal (CC) and mediolateral examinations to record the entrance skin dose (ESD). TLD readings were obtained at the Center for Energy Research and Training Zaria, Kaduna State, Nigeria. Dance formula was used to convert ESD to mean glandular dose (MGD). Student's t-test was used to determine the relationship between the mean ESD obtained in the two centers and Pearson's correlation was used to determine the relationship between the MGD and anthropotechnical parameters. Statistical significance was set at P < 0.05. Results: The total MGD for this study was 0.31 ± 0.05 mGy and 0.69 ± 0.11 mGy for CC and mediolateral oblique (MLO), respectively. DRL was 0.63 mGy and 1.04 mGy for CC and MLO, respectively. There was no statistically significant relationship (P > 0.05) between the MGD and anthropotechnical parameters. The DRL in this work were higher when compared with international established work. Conclusion: There is need for optimization of our radiology practice in North Eastern Nigeria and most centers in Nigeria.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信