水样品中的钾测定(K)使用光米火焰验证

Adelia Yuni Dwiputri, Febi Indah Fajarwati, B. C. Matahelumual
{"title":"水样品中的钾测定(K)使用光米火焰验证","authors":"Adelia Yuni Dwiputri, Febi Indah Fajarwati, B. C. Matahelumual","doi":"10.20885/ijcr.vol6.iss1.art3","DOIUrl":null,"url":null,"abstract":"Measurement of potassium levels in tap water using the flame photometric method and validating the flame photometric method. Validation was carried out at the Water Laboratory, Groundwater Center and Environmental Geology Bandung. The test parameters for validation include linearity, accuracy, precision, detection limit and quantitation limit. The results of determining the validation parameters obtained good linearity, indicated by the correlation coefficient value of 0.9998, detection limit of 3.681 mg / l, quantity limit of 12.27 mg / l, good precision indicated by% RSD of 1.139%, good accuracy indicated by the% recovery value of 103.88%, based on the t test and F test.","PeriodicalId":33936,"journal":{"name":"Indonesian Journal of Chemical Research","volume":"32 1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-08-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"VALIDASI PENENTUAN KALIUM (K) DALAM SAMPEL AIR MENGGUNAKAN FLAME FOTOMETER\",\"authors\":\"Adelia Yuni Dwiputri, Febi Indah Fajarwati, B. C. Matahelumual\",\"doi\":\"10.20885/ijcr.vol6.iss1.art3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Measurement of potassium levels in tap water using the flame photometric method and validating the flame photometric method. Validation was carried out at the Water Laboratory, Groundwater Center and Environmental Geology Bandung. The test parameters for validation include linearity, accuracy, precision, detection limit and quantitation limit. The results of determining the validation parameters obtained good linearity, indicated by the correlation coefficient value of 0.9998, detection limit of 3.681 mg / l, quantity limit of 12.27 mg / l, good precision indicated by% RSD of 1.139%, good accuracy indicated by the% recovery value of 103.88%, based on the t test and F test.\",\"PeriodicalId\":33936,\"journal\":{\"name\":\"Indonesian Journal of Chemical Research\",\"volume\":\"32 1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-08-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Indonesian Journal of Chemical Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.20885/ijcr.vol6.iss1.art3\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indonesian Journal of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20885/ijcr.vol6.iss1.art3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

用火焰光度法测定自来水中的钾含量及验证火焰光度法。在万隆水实验室、地下水中心和环境地质中心进行了验证。验证的检测参数包括线性度、准确度、精密度、检出限和定量限。通过t检验和F检验,验证参数的确定具有良好的线性关系,相关系数为0.9998,检出限为3.681 mg / l,定量限为12.27 mg / l,精密度为1.139%,回收率为103.88%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
VALIDASI PENENTUAN KALIUM (K) DALAM SAMPEL AIR MENGGUNAKAN FLAME FOTOMETER
Measurement of potassium levels in tap water using the flame photometric method and validating the flame photometric method. Validation was carried out at the Water Laboratory, Groundwater Center and Environmental Geology Bandung. The test parameters for validation include linearity, accuracy, precision, detection limit and quantitation limit. The results of determining the validation parameters obtained good linearity, indicated by the correlation coefficient value of 0.9998, detection limit of 3.681 mg / l, quantity limit of 12.27 mg / l, good precision indicated by% RSD of 1.139%, good accuracy indicated by the% recovery value of 103.88%, based on the t test and F test.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
39
审稿时长
4 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信