盆腔前环固定采用原始金属结构的分析

Q3 Medicine
A. Lazarev, E. Solod, Y. Gudushauri, E. Kalinin, V. Konovalov, I. N. Marychev
{"title":"盆腔前环固定采用原始金属结构的分析","authors":"A. Lazarev, E. Solod, Y. Gudushauri, E. Kalinin, V. Konovalov, I. N. Marychev","doi":"10.18019/1028-4427-2022-28-6-760-767","DOIUrl":null,"url":null,"abstract":"Introduction Stabilization of chronic injuries of the pelvic ring with standard methods may result in plate breach, destabilization of the implant and the need for repeated operations. Therefore, it has become necessary to use special tactical approaches in surgical treatment of chronic injuries for fixing traumatic foci and searching for adapted implant designs for such cases. Thus, an original plate has been developed. Purpose To study the features of fixation of chronic injuries of the pelvic ring using an original plate in comparison with the standard approach. Materials and methods We conducted a retrospective analysis of the surgical treatment performed using the developed plate (Group 2) and a group of patients who underwent fixation of the anterior pelvic ring with two reconstruction plates (Group 1). Results In group 1, four patients (16.7 %) had failed osteosynthesis within two weeks to two months after the operation. In group 2, thirty patients underwent surgical treatment using the developed design, and destabilization of the metal construct was detected only in 2 patients (6.6 %). In one case, migration of plate screws was detected after 3 years during routine X-ray study while the patient was not bothered by pain and did not feel any instability. Discussion Analyzing the positive and negative aspects of the methods used, we made a choice in favor of internal plating. Due to cases of destabilization of fixation using one or two plates, an original metal structure was developed and applied to strengthen fixation. Conclusion Changing the standard approaches to the treatment of chronic injuries (after 3 weeks since injury) of the anterior pelvic ring enables to create conditions for stable fixation, using the original monolithic plate, despite the rigidity of the pelvic ring in chronic injuries.","PeriodicalId":37426,"journal":{"name":"Genij Ortopedii","volume":"131 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis of the use of original metal structures for anterior pelvic ring fixation\",\"authors\":\"A. Lazarev, E. Solod, Y. Gudushauri, E. Kalinin, V. Konovalov, I. N. Marychev\",\"doi\":\"10.18019/1028-4427-2022-28-6-760-767\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction Stabilization of chronic injuries of the pelvic ring with standard methods may result in plate breach, destabilization of the implant and the need for repeated operations. Therefore, it has become necessary to use special tactical approaches in surgical treatment of chronic injuries for fixing traumatic foci and searching for adapted implant designs for such cases. Thus, an original plate has been developed. Purpose To study the features of fixation of chronic injuries of the pelvic ring using an original plate in comparison with the standard approach. Materials and methods We conducted a retrospective analysis of the surgical treatment performed using the developed plate (Group 2) and a group of patients who underwent fixation of the anterior pelvic ring with two reconstruction plates (Group 1). Results In group 1, four patients (16.7 %) had failed osteosynthesis within two weeks to two months after the operation. In group 2, thirty patients underwent surgical treatment using the developed design, and destabilization of the metal construct was detected only in 2 patients (6.6 %). In one case, migration of plate screws was detected after 3 years during routine X-ray study while the patient was not bothered by pain and did not feel any instability. Discussion Analyzing the positive and negative aspects of the methods used, we made a choice in favor of internal plating. Due to cases of destabilization of fixation using one or two plates, an original metal structure was developed and applied to strengthen fixation. Conclusion Changing the standard approaches to the treatment of chronic injuries (after 3 weeks since injury) of the anterior pelvic ring enables to create conditions for stable fixation, using the original monolithic plate, despite the rigidity of the pelvic ring in chronic injuries.\",\"PeriodicalId\":37426,\"journal\":{\"name\":\"Genij Ortopedii\",\"volume\":\"131 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Genij Ortopedii\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18019/1028-4427-2022-28-6-760-767\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Genij Ortopedii","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18019/1028-4427-2022-28-6-760-767","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

采用标准方法稳定盆腔环慢性损伤可能导致钢板断裂、植入物不稳定以及需要重复手术。因此,在慢性损伤的外科治疗中,有必要采用特殊的战术方法来固定创伤灶,并为此类病例寻找适合的种植体设计。这样,就形成了一个原始版。目的探讨原始钢板与标准入路固定盆腔环慢性损伤的特点。材料和方法我们回顾性分析了使用发育钢板进行的手术治疗(2组)和使用两个重建钢板固定骨盆前环的患者(1组)。结果在1组中,4例(16.7%)患者在手术后2周至2个月内骨固定失败。在第二组中,30例患者使用开发的设计进行了手术治疗,只有2例患者(6.6%)检测到金属结构的不稳定。1例患者在3年后的常规x线检查中发现钢板螺钉移位,患者没有疼痛,也没有任何不稳定感。通过对所采用方法的利弊分析,我们选择了内镀法。由于使用一个或两个钢板固定失稳的情况,一种原始的金属结构被开发并应用于加强固定。结论改变盆腔前环慢性损伤(损伤后3周)的标准治疗方法,尽管盆腔前环在慢性损伤中具有刚性,但可以使用原有的整体式钢板为稳定固定创造条件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Analysis of the use of original metal structures for anterior pelvic ring fixation
Introduction Stabilization of chronic injuries of the pelvic ring with standard methods may result in plate breach, destabilization of the implant and the need for repeated operations. Therefore, it has become necessary to use special tactical approaches in surgical treatment of chronic injuries for fixing traumatic foci and searching for adapted implant designs for such cases. Thus, an original plate has been developed. Purpose To study the features of fixation of chronic injuries of the pelvic ring using an original plate in comparison with the standard approach. Materials and methods We conducted a retrospective analysis of the surgical treatment performed using the developed plate (Group 2) and a group of patients who underwent fixation of the anterior pelvic ring with two reconstruction plates (Group 1). Results In group 1, four patients (16.7 %) had failed osteosynthesis within two weeks to two months after the operation. In group 2, thirty patients underwent surgical treatment using the developed design, and destabilization of the metal construct was detected only in 2 patients (6.6 %). In one case, migration of plate screws was detected after 3 years during routine X-ray study while the patient was not bothered by pain and did not feel any instability. Discussion Analyzing the positive and negative aspects of the methods used, we made a choice in favor of internal plating. Due to cases of destabilization of fixation using one or two plates, an original metal structure was developed and applied to strengthen fixation. Conclusion Changing the standard approaches to the treatment of chronic injuries (after 3 weeks since injury) of the anterior pelvic ring enables to create conditions for stable fixation, using the original monolithic plate, despite the rigidity of the pelvic ring in chronic injuries.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Genij Ortopedii
Genij Ortopedii Medicine-Surgery
CiteScore
0.70
自引率
0.00%
发文量
104
审稿时长
12 weeks
期刊介绍: Journal’s main goal is to contribute to the development of the contemporary medical science via presentation of fundamental and applied original scientific studies to the scientific and practical medical community that would widen and deepen the understanding of the most important problems in the field of traumatology, orthopaedics, and related specialties. Our journal provides a direct open access to its content which is based on the principle that the open access option promotes global exchange of knowledge and experience. Journal’s strategy: -Development of the journal as a scientific platform for researchers, doctors, post-graduates and residents -Attraction of highly-cited authors to publish their studies -Selection of manuscripts of scientific interest for readers that will impact on journal citation index in RINC -Increase in the portion of publications submitted by foreign authors and studies conducted in association with foreign scientists; growth of citations in the journals that are included into global systems of indexing and reputable databases -Improvement of the Journal’s web site in two languages for a greater accessibility by authors and readers -Introduction of the Journal into global indexing systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信