{"title":"飞秒LASIK虹膜定位与Kappa角矫正的临床疗效比较","authors":"Q. Lin, Xuexi Li","doi":"10.3760/CMA.J.ISSN.1006-4443.2017.08.014","DOIUrl":null,"url":null,"abstract":"Objective \nTo compare the clinical curative effect of iris localization and Kappa Angle correction on femtosecond LASIK surgery. \n \n \nMethods \nProspective randomized controlled study. Matching t test was used on two groups of postoperative 1 month visual acuity, contrast sensitivity respectively and preoperative best corrected visual acuity, best corrected vision wear glasses measuring contrast sensitivity. Two independent sample t test and nonparametric test were used on between the two groups of postoperative 1 month visual acuity, contrast sensitivity compared with preoperative best corrected visual acuity, best corrected vision wear glasses contrast sensitivity increased value and Pentacam measurement of cutting off center value pairs. Two groups of postoperative 1 month visual acuity, contrast sensitivity increased value with Pentacam measurement of cutting off center value, postoperative residual spherical mirror, l enticular mirror and cylindrical mirror axis for correlation analysis. \n \n \nResults \nTwo groups of postoperative 1 month visual acuity, contrast sensitivity and preoperative best corrected visual acuity, best corrected vision wear glasses measuring contrast sensitivity difference was statistically significant. Between the two groups of postoperative 1 month visual acuity, contrast sensitivity and Pentacam measurement of cutting off center value differences had no statistical significance. \n \n \nConclusions \nThe two kinds of operation method can effectively avoid cutting off center of LASIK, get better than that of preoperative vision and contrast sensitivity. Two kinds of operation method postoperative visual acuity, contrast sensitivity increase value and cutting off center has no difference. \n \n \nKey words: \nFemtosecond laser; The iris localization; Kappa Angle correction","PeriodicalId":10236,"journal":{"name":"中国实用眼科杂志","volume":"143 1","pages":"808-812"},"PeriodicalIF":0.0000,"publicationDate":"2017-08-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Clinical curative effect comparison of the iris localization and Kappa angle correction femtosecond LASIK\",\"authors\":\"Q. Lin, Xuexi Li\",\"doi\":\"10.3760/CMA.J.ISSN.1006-4443.2017.08.014\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective \\nTo compare the clinical curative effect of iris localization and Kappa Angle correction on femtosecond LASIK surgery. \\n \\n \\nMethods \\nProspective randomized controlled study. Matching t test was used on two groups of postoperative 1 month visual acuity, contrast sensitivity respectively and preoperative best corrected visual acuity, best corrected vision wear glasses measuring contrast sensitivity. Two independent sample t test and nonparametric test were used on between the two groups of postoperative 1 month visual acuity, contrast sensitivity compared with preoperative best corrected visual acuity, best corrected vision wear glasses contrast sensitivity increased value and Pentacam measurement of cutting off center value pairs. Two groups of postoperative 1 month visual acuity, contrast sensitivity increased value with Pentacam measurement of cutting off center value, postoperative residual spherical mirror, l enticular mirror and cylindrical mirror axis for correlation analysis. \\n \\n \\nResults \\nTwo groups of postoperative 1 month visual acuity, contrast sensitivity and preoperative best corrected visual acuity, best corrected vision wear glasses measuring contrast sensitivity difference was statistically significant. Between the two groups of postoperative 1 month visual acuity, contrast sensitivity and Pentacam measurement of cutting off center value differences had no statistical significance. \\n \\n \\nConclusions \\nThe two kinds of operation method can effectively avoid cutting off center of LASIK, get better than that of preoperative vision and contrast sensitivity. Two kinds of operation method postoperative visual acuity, contrast sensitivity increase value and cutting off center has no difference. \\n \\n \\nKey words: \\nFemtosecond laser; The iris localization; Kappa Angle correction\",\"PeriodicalId\":10236,\"journal\":{\"name\":\"中国实用眼科杂志\",\"volume\":\"143 1\",\"pages\":\"808-812\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-08-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中国实用眼科杂志\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3760/CMA.J.ISSN.1006-4443.2017.08.014\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国实用眼科杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/CMA.J.ISSN.1006-4443.2017.08.014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Clinical curative effect comparison of the iris localization and Kappa angle correction femtosecond LASIK
Objective
To compare the clinical curative effect of iris localization and Kappa Angle correction on femtosecond LASIK surgery.
Methods
Prospective randomized controlled study. Matching t test was used on two groups of postoperative 1 month visual acuity, contrast sensitivity respectively and preoperative best corrected visual acuity, best corrected vision wear glasses measuring contrast sensitivity. Two independent sample t test and nonparametric test were used on between the two groups of postoperative 1 month visual acuity, contrast sensitivity compared with preoperative best corrected visual acuity, best corrected vision wear glasses contrast sensitivity increased value and Pentacam measurement of cutting off center value pairs. Two groups of postoperative 1 month visual acuity, contrast sensitivity increased value with Pentacam measurement of cutting off center value, postoperative residual spherical mirror, l enticular mirror and cylindrical mirror axis for correlation analysis.
Results
Two groups of postoperative 1 month visual acuity, contrast sensitivity and preoperative best corrected visual acuity, best corrected vision wear glasses measuring contrast sensitivity difference was statistically significant. Between the two groups of postoperative 1 month visual acuity, contrast sensitivity and Pentacam measurement of cutting off center value differences had no statistical significance.
Conclusions
The two kinds of operation method can effectively avoid cutting off center of LASIK, get better than that of preoperative vision and contrast sensitivity. Two kinds of operation method postoperative visual acuity, contrast sensitivity increase value and cutting off center has no difference.
Key words:
Femtosecond laser; The iris localization; Kappa Angle correction
期刊介绍:
China Practical Ophthalmology was founded in May 1983. It is supervised by the National Health Commission of the People's Republic of China, sponsored by the Chinese Medical Association and China Medical University, and publicly distributed at home and abroad. It is a national-level excellent core academic journal of comprehensive ophthalmology and a series of journals of the Chinese Medical Association.
China Practical Ophthalmology aims to guide and improve the theoretical level and actual clinical diagnosis and treatment ability of frontline ophthalmologists in my country. It is characterized by close integration with clinical practice, and timely publishes academic articles and scientific research results with high practical value to clinicians, so that readers can understand and use them, improve the theoretical level and diagnosis and treatment ability of ophthalmologists, help and support their innovative development, and is deeply welcomed and loved by ophthalmologists and readers.