孟加拉国四家医院暗影x线摄影中一些常规x线成像参数的调查

Sadeka Sultana Rubai, Santunu Purohit, T. Siddiqua, Md. Shakilur Rahman, A. Meaze
{"title":"孟加拉国四家医院暗影x线摄影中一些常规x线成像参数的调查","authors":"Sadeka Sultana Rubai, Santunu Purohit, T. Siddiqua, Md. Shakilur Rahman, A. Meaze","doi":"10.53848/ssstj.v10i2.239","DOIUrl":null,"url":null,"abstract":"Analytic radiography is a normal image testing technique which has been utilized for quite a long time. It is recommended by specialists so they can identify any problem in patients' bodies without a cut. Thinking about its wide use, the principle objective of this investigation is to give a top notch picture by keeping the radiation portion as low as conceivable through identifying any variety in quality control (QC) boundaries. In this work, some standard quality control boundaries, for example, voltage exactness, time precision test, tube yield linearity, half value layer (HVL) of x-beam were measured. These quality control (QC) boundaries were estimated by a dosimeter keeping a distance of 100 cm from source. The voltage precision went from 0.31% to 4.67% and the time exactness test went from 0% to 2.29%. The consequences of this investigation show that all the QC boundaries are inside the acceptable level which guarantees the advancement of the low portion conveyed to the patients.","PeriodicalId":31349,"journal":{"name":"Suan Sunandha Rajabhat University Journal of Science and Technology","volume":"148 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigation of some regular x-ray imaging parameters in suggestive radiography of four hospitals in Bangladesh\",\"authors\":\"Sadeka Sultana Rubai, Santunu Purohit, T. Siddiqua, Md. Shakilur Rahman, A. Meaze\",\"doi\":\"10.53848/ssstj.v10i2.239\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Analytic radiography is a normal image testing technique which has been utilized for quite a long time. It is recommended by specialists so they can identify any problem in patients' bodies without a cut. Thinking about its wide use, the principle objective of this investigation is to give a top notch picture by keeping the radiation portion as low as conceivable through identifying any variety in quality control (QC) boundaries. In this work, some standard quality control boundaries, for example, voltage exactness, time precision test, tube yield linearity, half value layer (HVL) of x-beam were measured. These quality control (QC) boundaries were estimated by a dosimeter keeping a distance of 100 cm from source. The voltage precision went from 0.31% to 4.67% and the time exactness test went from 0% to 2.29%. The consequences of this investigation show that all the QC boundaries are inside the acceptable level which guarantees the advancement of the low portion conveyed to the patients.\",\"PeriodicalId\":31349,\"journal\":{\"name\":\"Suan Sunandha Rajabhat University Journal of Science and Technology\",\"volume\":\"148 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Suan Sunandha Rajabhat University Journal of Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.53848/ssstj.v10i2.239\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Suan Sunandha Rajabhat University Journal of Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.53848/ssstj.v10i2.239","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

放射分析成像技术是一种常规的图像检测技术,已经应用了相当长的时间。专家建议这样做,这样他们就可以在不切割的情况下识别患者身体的任何问题。考虑到它的广泛应用,本调查的主要目标是通过识别质量控制(QC)边界的任何变化,通过保持辐射部分尽可能低,给出一个一流的图片。本文对x射线的电压精度、时间精度、管屈服度线性度、半值层(HVL)等标准质量控制边界进行了测量。这些质量控制(QC)边界是由距离源保持100厘米的剂量计估计的。电压精度从0.31%提高到4.67%,时间精度从0%提高到2.29%。本次调查的结果表明,所有的质量控制边界都在可接受的水平内,这保证了向患者传达的低部分的进展。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Investigation of some regular x-ray imaging parameters in suggestive radiography of four hospitals in Bangladesh
Analytic radiography is a normal image testing technique which has been utilized for quite a long time. It is recommended by specialists so they can identify any problem in patients' bodies without a cut. Thinking about its wide use, the principle objective of this investigation is to give a top notch picture by keeping the radiation portion as low as conceivable through identifying any variety in quality control (QC) boundaries. In this work, some standard quality control boundaries, for example, voltage exactness, time precision test, tube yield linearity, half value layer (HVL) of x-beam were measured. These quality control (QC) boundaries were estimated by a dosimeter keeping a distance of 100 cm from source. The voltage precision went from 0.31% to 4.67% and the time exactness test went from 0% to 2.29%. The consequences of this investigation show that all the QC boundaries are inside the acceptable level which guarantees the advancement of the low portion conveyed to the patients.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信