研究阴极几何形状对氮直流辉光放电I-V特性的影响

A. A. Khadayeir, Wessam M. Taher
{"title":"研究阴极几何形状对氮直流辉光放电I-V特性的影响","authors":"A. A. Khadayeir, Wessam M. Taher","doi":"10.31257/2018/JKP/2019/110110","DOIUrl":null,"url":null,"abstract":"In this paper, the I-V characteristic of a dc glow discharge are studied with the aim of determine the performance a good parametersfor stable operation of the plasma. Nitrogen plasma produced by dc glow discharge is the investigated with a manypurpose of studying plasma phenomena, the discharge system consists of two electrodes, the cathode forms various geometrical shapes and anode as a disc- shaped with diameter (8.8cm). The electrodes are enclosed in a large cylindrical glass chamber of pyrex filled with nitrogen gas. Two important physical parameters affecting the condition of the discharge are the gas pressure and constant inter-electrode distance. The discharge current-voltage (I-V) characteristic curves of the discharge were measured at variable pressure and the inter-electrode spacing, Current-voltage characteristics visualization of the discharge indicate that the discharge is take place in the normal glow region. The (I-V) characteristics of nitrogen gas discharge were deduced as a plasma system operated in normal glow discharge nitrogen, which is very important parameter in the sputtering and deposition. Also, the discharge current is increased for nitrogen plasma discharge with the increasing of the working pressure lead to increase the deposition rate. DIO.: http://dx.doi.org/10.31257/2018/JKP/2019/110110","PeriodicalId":16215,"journal":{"name":"Journal of Kufa - Physics","volume":"45 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Study the effect of cathode geometry on I-V characteristics of nitrogen dc glow discharge\",\"authors\":\"A. A. Khadayeir, Wessam M. Taher\",\"doi\":\"10.31257/2018/JKP/2019/110110\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, the I-V characteristic of a dc glow discharge are studied with the aim of determine the performance a good parametersfor stable operation of the plasma. Nitrogen plasma produced by dc glow discharge is the investigated with a manypurpose of studying plasma phenomena, the discharge system consists of two electrodes, the cathode forms various geometrical shapes and anode as a disc- shaped with diameter (8.8cm). The electrodes are enclosed in a large cylindrical glass chamber of pyrex filled with nitrogen gas. Two important physical parameters affecting the condition of the discharge are the gas pressure and constant inter-electrode distance. The discharge current-voltage (I-V) characteristic curves of the discharge were measured at variable pressure and the inter-electrode spacing, Current-voltage characteristics visualization of the discharge indicate that the discharge is take place in the normal glow region. The (I-V) characteristics of nitrogen gas discharge were deduced as a plasma system operated in normal glow discharge nitrogen, which is very important parameter in the sputtering and deposition. Also, the discharge current is increased for nitrogen plasma discharge with the increasing of the working pressure lead to increase the deposition rate. DIO.: http://dx.doi.org/10.31257/2018/JKP/2019/110110\",\"PeriodicalId\":16215,\"journal\":{\"name\":\"Journal of Kufa - Physics\",\"volume\":\"45 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-06-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Kufa - Physics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31257/2018/JKP/2019/110110\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Kufa - Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31257/2018/JKP/2019/110110","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文研究了直流辉光放电的I-V特性,目的是确定等离子体的性能和稳定运行的良好参数。以直流辉光放电产生的氮等离子体为研究对象,该放电系统由两个电极组成,阴极呈各种几何形状,阳极呈直径为8.8cm的圆盘状。电极被封闭在一个充满氮气的大圆柱形耐热玻璃室中。影响放电条件的两个重要物理参数是气体压力和电极间的恒定距离。在变压力和电极间距下测量了放电的电流-电压(I-V)特性曲线,显示了放电的电流-电压特性,表明放电发生在正常发光区域。推导了等离子体系统在正常辉光放电氮气条件下的放电(I-V)特性,这是溅射和沉积过程中的一个重要参数。氮等离子体放电的放电电流随着工作压力的增大而增大,导致沉积速率增大。戴奥。: http://dx.doi.org/10.31257/2018/JKP/2019/110110
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Study the effect of cathode geometry on I-V characteristics of nitrogen dc glow discharge
In this paper, the I-V characteristic of a dc glow discharge are studied with the aim of determine the performance a good parametersfor stable operation of the plasma. Nitrogen plasma produced by dc glow discharge is the investigated with a manypurpose of studying plasma phenomena, the discharge system consists of two electrodes, the cathode forms various geometrical shapes and anode as a disc- shaped with diameter (8.8cm). The electrodes are enclosed in a large cylindrical glass chamber of pyrex filled with nitrogen gas. Two important physical parameters affecting the condition of the discharge are the gas pressure and constant inter-electrode distance. The discharge current-voltage (I-V) characteristic curves of the discharge were measured at variable pressure and the inter-electrode spacing, Current-voltage characteristics visualization of the discharge indicate that the discharge is take place in the normal glow region. The (I-V) characteristics of nitrogen gas discharge were deduced as a plasma system operated in normal glow discharge nitrogen, which is very important parameter in the sputtering and deposition. Also, the discharge current is increased for nitrogen plasma discharge with the increasing of the working pressure lead to increase the deposition rate. DIO.: http://dx.doi.org/10.31257/2018/JKP/2019/110110
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信