{"title":"以溴百里香酚蓝为指示电极的新型传感器电极的合成及其在水溶液电位酸碱滴定中的应用","authors":"Nasser M Abu Ghalwa","doi":"10.19080/omcij.2019.09.555764","DOIUrl":null,"url":null,"abstract":"A modified bromothymol blue BTB electrode was prepared by spin coating of the BTB indicator on conducting glass substrate, and its use as indicator electrode to potentiometric acid-base titration in aqueous solution at 298 K was developed. The change of the open circuit potential with pH (E-pH) curve is linear with slope of 0.052 V/Dec at 298 K. The standard potential of this electrode, E0, was determined with respect to the SCE as reference electrode. The recovery percentage for potentiometric acid-base titration using G/BTB as indicator electrode was calculated","PeriodicalId":19547,"journal":{"name":"Organic & Medicinal Chemistry International Journal","volume":"22 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-03-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Synthesis of a Novel Sensor Electrode Based on Bromothymol Blue as an Indicator Electrode in Potentiometric Acid-Base Titration in Aqueous Solution\",\"authors\":\"Nasser M Abu Ghalwa\",\"doi\":\"10.19080/omcij.2019.09.555764\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A modified bromothymol blue BTB electrode was prepared by spin coating of the BTB indicator on conducting glass substrate, and its use as indicator electrode to potentiometric acid-base titration in aqueous solution at 298 K was developed. The change of the open circuit potential with pH (E-pH) curve is linear with slope of 0.052 V/Dec at 298 K. The standard potential of this electrode, E0, was determined with respect to the SCE as reference electrode. The recovery percentage for potentiometric acid-base titration using G/BTB as indicator electrode was calculated\",\"PeriodicalId\":19547,\"journal\":{\"name\":\"Organic & Medicinal Chemistry International Journal\",\"volume\":\"22 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-03-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Organic & Medicinal Chemistry International Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.19080/omcij.2019.09.555764\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Organic & Medicinal Chemistry International Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.19080/omcij.2019.09.555764","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Synthesis of a Novel Sensor Electrode Based on Bromothymol Blue as an Indicator Electrode in Potentiometric Acid-Base Titration in Aqueous Solution
A modified bromothymol blue BTB electrode was prepared by spin coating of the BTB indicator on conducting glass substrate, and its use as indicator electrode to potentiometric acid-base titration in aqueous solution at 298 K was developed. The change of the open circuit potential with pH (E-pH) curve is linear with slope of 0.052 V/Dec at 298 K. The standard potential of this electrode, E0, was determined with respect to the SCE as reference electrode. The recovery percentage for potentiometric acid-base titration using G/BTB as indicator electrode was calculated