使用iTrace分析仪检测丙烯软®IQ PanOptix®/PanOptix®TORIC晶体植入后的视力与术前瞳孔大小值、角度Alpha和Kappa的关系

Cywinski A
{"title":"使用iTrace分析仪检测丙烯软®IQ PanOptix®/PanOptix®TORIC晶体植入后的视力与术前瞳孔大小值、角度Alpha和Kappa的关系","authors":"Cywinski A","doi":"10.23880/oajo-16000229","DOIUrl":null,"url":null,"abstract":"Visual acuity of 35 patients (49 eyes) implanted with AcrySoft®IQ PanOptix® spherical or toric lenses by Alcon was analyzed considering preoperative pupil size, angles alpha and kappa, the values of which were obtained in the examination using iTrace analyzer. Overall, no statistically significant changes in visual acuity were observed for changing values of the above parameters, except in the preoperative group with hyperopia, in which visual acuity to far distances improved with increasing pupil size. In some patients after refractive lens exchange, a slight deterioration in visual acuity to far distances was observed compared to preoperative values obtained with best correction; however, this did not have a significant impact on the level of patient satisfaction.","PeriodicalId":91939,"journal":{"name":"Open access journal of ophthalmology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-07-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Visual Acuity after AcrySoft®IQ PanOptix®/PanOptix® TORIC Lens Implantation in Relation to Preoperative Pupil Size Values, Angles Alpha and Kappa Examined using the iTrace Analyzer\",\"authors\":\"Cywinski A\",\"doi\":\"10.23880/oajo-16000229\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Visual acuity of 35 patients (49 eyes) implanted with AcrySoft®IQ PanOptix® spherical or toric lenses by Alcon was analyzed considering preoperative pupil size, angles alpha and kappa, the values of which were obtained in the examination using iTrace analyzer. Overall, no statistically significant changes in visual acuity were observed for changing values of the above parameters, except in the preoperative group with hyperopia, in which visual acuity to far distances improved with increasing pupil size. In some patients after refractive lens exchange, a slight deterioration in visual acuity to far distances was observed compared to preoperative values obtained with best correction; however, this did not have a significant impact on the level of patient satisfaction.\",\"PeriodicalId\":91939,\"journal\":{\"name\":\"Open access journal of ophthalmology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-07-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Open access journal of ophthalmology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23880/oajo-16000229\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open access journal of ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23880/oajo-16000229","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

对35例(49只眼)植入爱尔康公司生产的丙稀软®IQ PanOptix®球型或环型人工晶状体患者的视力进行分析,采用iTrace分析仪检测术前瞳孔大小、α角和kappa角。总体而言,上述参数值的变化对视力的影响均无统计学意义,但术前远视组除外,远视随瞳孔增大而改善。在屈光晶体置换后的一些患者中,与术前最佳矫正所获得的视力相比,观察到远处的视力略有下降;然而,这对患者满意度水平没有显著影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Visual Acuity after AcrySoft®IQ PanOptix®/PanOptix® TORIC Lens Implantation in Relation to Preoperative Pupil Size Values, Angles Alpha and Kappa Examined using the iTrace Analyzer
Visual acuity of 35 patients (49 eyes) implanted with AcrySoft®IQ PanOptix® spherical or toric lenses by Alcon was analyzed considering preoperative pupil size, angles alpha and kappa, the values of which were obtained in the examination using iTrace analyzer. Overall, no statistically significant changes in visual acuity were observed for changing values of the above parameters, except in the preoperative group with hyperopia, in which visual acuity to far distances improved with increasing pupil size. In some patients after refractive lens exchange, a slight deterioration in visual acuity to far distances was observed compared to preoperative values obtained with best correction; however, this did not have a significant impact on the level of patient satisfaction.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信