耳蜗体积对人工耳蜗患者时间阻抗变化的影响

H. Pauna, M. S. A. do Amaral, Daniela S. Fonseca, R. Pessini, Denny M. Garcia, J. Echeverria, A. Guimarães, V. A. R. da Silva, M. Hyppolito
{"title":"耳蜗体积对人工耳蜗患者时间阻抗变化的影响","authors":"H. Pauna, M. S. A. do Amaral, Daniela S. Fonseca, R. Pessini, Denny M. Garcia, J. Echeverria, A. Guimarães, V. A. R. da Silva, M. Hyppolito","doi":"10.3390/ohbm4010003","DOIUrl":null,"url":null,"abstract":"Background: There is evidence that the cochlear volume may influence audiometric thresholds and CI electrodes’ impedance. The aim of the present study was to evaluate the impedance changes over time and correlate them to the residual volume of the cochlea. Methods: An MRI scan was performed via 3-D reconstruction before every surgery to obtain a residual volume for each ear. We performed repeated assessments of electrode impedance, both intra-operatively and post-implant, at the following intervals: 3 months, 6 months, and one year. The same type of perimodiolar array was implanted for each. Results: Thirty-four patients (10 (29.41%) male patients and 24 (70.59%) female patients) were evaluated. Patients received the implants between 2008 and 2017. The mean age of implantation was 13 ± 17.17 years, and the average of hearing thresholds improved after one year of the surgery. The mean cochlear volumes of the implanted ears were 68.16 ± 10.74 mm3 (right ear) and 56.54 ± 13.75 mm3 (left ear). We observed an increase in the basal electrodes’ impedance at the 3rd month. Yet, for the apical electrodes’ impedance, there was a decrease in averaged values. Conclusions: Post-operative impedance measurements were increased when compared to the intraoperatively measured basal values. Newly formed connective tissue is thought to be the cause of the higher impedance values.","PeriodicalId":73883,"journal":{"name":"Journal of otorhinolaryngology, hearing and balance medicine","volume":"35 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Influence of Cochlear Volume on Temporal Changes of Impedance among Cochlear Implant Patients\",\"authors\":\"H. Pauna, M. S. A. do Amaral, Daniela S. Fonseca, R. Pessini, Denny M. Garcia, J. Echeverria, A. Guimarães, V. A. R. da Silva, M. Hyppolito\",\"doi\":\"10.3390/ohbm4010003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: There is evidence that the cochlear volume may influence audiometric thresholds and CI electrodes’ impedance. The aim of the present study was to evaluate the impedance changes over time and correlate them to the residual volume of the cochlea. Methods: An MRI scan was performed via 3-D reconstruction before every surgery to obtain a residual volume for each ear. We performed repeated assessments of electrode impedance, both intra-operatively and post-implant, at the following intervals: 3 months, 6 months, and one year. The same type of perimodiolar array was implanted for each. Results: Thirty-four patients (10 (29.41%) male patients and 24 (70.59%) female patients) were evaluated. Patients received the implants between 2008 and 2017. The mean age of implantation was 13 ± 17.17 years, and the average of hearing thresholds improved after one year of the surgery. The mean cochlear volumes of the implanted ears were 68.16 ± 10.74 mm3 (right ear) and 56.54 ± 13.75 mm3 (left ear). We observed an increase in the basal electrodes’ impedance at the 3rd month. Yet, for the apical electrodes’ impedance, there was a decrease in averaged values. Conclusions: Post-operative impedance measurements were increased when compared to the intraoperatively measured basal values. Newly formed connective tissue is thought to be the cause of the higher impedance values.\",\"PeriodicalId\":73883,\"journal\":{\"name\":\"Journal of otorhinolaryngology, hearing and balance medicine\",\"volume\":\"35 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-05-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of otorhinolaryngology, hearing and balance medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/ohbm4010003\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of otorhinolaryngology, hearing and balance medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/ohbm4010003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:有证据表明,耳蜗体积可能影响听力学阈值和CI电极阻抗。本研究的目的是评估阻抗随时间的变化,并将其与耳蜗残余容量相关联。方法:每次手术前通过三维重建进行MRI扫描,以获得每只耳朵的残余体积。我们对电极阻抗进行了重复评估,包括术中和植入后,时间间隔如下:3个月、6个月和1年。分别植入相同类型的磨牙周围阵列。结果:共评价34例患者,其中男性10例(29.41%),女性24例(70.59%)。患者在2008年至2017年期间接受了植入物。平均植入术年龄为13±17.17岁,术后1年平均听力阈值有所改善。耳蜗体积平均右耳为68.16±10.74 mm3,左耳为56.54±13.75 mm3。我们在第3个月观察到基础电极阻抗的增加。然而,对于顶端电极的阻抗,平均值有所下降。结论:与术中测量的基础值相比,术后阻抗测量值增加。新形成的结缔组织被认为是高阻抗值的原因。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Influence of Cochlear Volume on Temporal Changes of Impedance among Cochlear Implant Patients
Background: There is evidence that the cochlear volume may influence audiometric thresholds and CI electrodes’ impedance. The aim of the present study was to evaluate the impedance changes over time and correlate them to the residual volume of the cochlea. Methods: An MRI scan was performed via 3-D reconstruction before every surgery to obtain a residual volume for each ear. We performed repeated assessments of electrode impedance, both intra-operatively and post-implant, at the following intervals: 3 months, 6 months, and one year. The same type of perimodiolar array was implanted for each. Results: Thirty-four patients (10 (29.41%) male patients and 24 (70.59%) female patients) were evaluated. Patients received the implants between 2008 and 2017. The mean age of implantation was 13 ± 17.17 years, and the average of hearing thresholds improved after one year of the surgery. The mean cochlear volumes of the implanted ears were 68.16 ± 10.74 mm3 (right ear) and 56.54 ± 13.75 mm3 (left ear). We observed an increase in the basal electrodes’ impedance at the 3rd month. Yet, for the apical electrodes’ impedance, there was a decrease in averaged values. Conclusions: Post-operative impedance measurements were increased when compared to the intraoperatively measured basal values. Newly formed connective tissue is thought to be the cause of the higher impedance values.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信