伊朗干热地区传统民居中央庭院相邻房间采光质量调查——以Yazdanpanah住宅为例

N. Tayari, M. Nikpour
{"title":"伊朗干热地区传统民居中央庭院相邻房间采光质量调查——以Yazdanpanah住宅为例","authors":"N. Tayari, M. Nikpour","doi":"10.5829/ijee.2022.13.04.01","DOIUrl":null,"url":null,"abstract":"Most of the spaces in contemporary houses in Iran cannot achieve enough daylight during daytime. Daylight utilization has a significant impact on decreasing energy consumption in residential buildings. Residents are deprived of natural daylight when there is no attention to the design based on daylight. Iranian traditional architects use practical and straightforward methods in constructing courtyards houses to provide comfort conditions in unique rooms in courtyard houses in terms of daylight quality. In this research, the daylight quality of five separate rooms around the courtyard of Yazdanpanah's house was investigated through an experimental method. Average work plane illuminance and uniformity ratio were calculated in these rooms of the house in Kerman city, located in Iran's hot and dry climate. Findings of this research demonstrated that all rooms surrounding the courtyard of traditional houses have the ability to achieve work plane illuminance of more than acceptable value. Among all rooms around the central courtyard, one room facing the south direction achieves more than 500 Lux work plane illuminance. The amount of uniformity in this room is acceptable with more than 0.5 on most of the days in a year. The findings of this research could be used to design more comfortable rooms in contemporary houses in terms of daylight quality by creating central courtyards. doi: 10.5829/ijee.2022.13.04.01","PeriodicalId":14542,"journal":{"name":"Iranian Journal of Energy and Environment","volume":"34 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Investigation on Daylight Quality of Central Courtyard’s Adjacent Rooms in Traditional Houses in Hot Dry Region of Iran: A Case Study Yazdanpanah House\",\"authors\":\"N. Tayari, M. Nikpour\",\"doi\":\"10.5829/ijee.2022.13.04.01\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Most of the spaces in contemporary houses in Iran cannot achieve enough daylight during daytime. Daylight utilization has a significant impact on decreasing energy consumption in residential buildings. Residents are deprived of natural daylight when there is no attention to the design based on daylight. Iranian traditional architects use practical and straightforward methods in constructing courtyards houses to provide comfort conditions in unique rooms in courtyard houses in terms of daylight quality. In this research, the daylight quality of five separate rooms around the courtyard of Yazdanpanah's house was investigated through an experimental method. Average work plane illuminance and uniformity ratio were calculated in these rooms of the house in Kerman city, located in Iran's hot and dry climate. Findings of this research demonstrated that all rooms surrounding the courtyard of traditional houses have the ability to achieve work plane illuminance of more than acceptable value. Among all rooms around the central courtyard, one room facing the south direction achieves more than 500 Lux work plane illuminance. The amount of uniformity in this room is acceptable with more than 0.5 on most of the days in a year. The findings of this research could be used to design more comfortable rooms in contemporary houses in terms of daylight quality by creating central courtyards. doi: 10.5829/ijee.2022.13.04.01\",\"PeriodicalId\":14542,\"journal\":{\"name\":\"Iranian Journal of Energy and Environment\",\"volume\":\"34 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iranian Journal of Energy and Environment\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5829/ijee.2022.13.04.01\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Energy and Environment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5829/ijee.2022.13.04.01","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

伊朗当代住宅的大部分空间在白天无法获得足够的日光。日光利用对减少住宅建筑的能源消耗具有重要影响。当不注意基于日光的设计时,居民被剥夺了自然光。伊朗传统建筑师使用实用和直接的方法来建造四合院,在四合院的独特房间中提供舒适的日光质量条件。在这项研究中,通过实验方法调查了Yazdanpanah家庭院周围五个独立房间的日光质量。在伊朗炎热干燥的气候条件下,克尔曼市的这些房间计算了平均工作面照度和均匀度比。本研究结果表明,传统民居庭院周围的所有房间都有能力实现工作平面照度超过可接受值。在中央庭院周围的所有房间中,一个朝南的房间达到了500勒克斯以上的工作平面照度。这个房间的均匀度是可以接受的,一年中大部分时间都在0.5以上。这项研究的结果可以通过创建中央庭院来设计现代住宅中更舒适的房间,从而提高日光质量。doi: 10.5829 / ijee.2022.13.04.01
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Investigation on Daylight Quality of Central Courtyard’s Adjacent Rooms in Traditional Houses in Hot Dry Region of Iran: A Case Study Yazdanpanah House
Most of the spaces in contemporary houses in Iran cannot achieve enough daylight during daytime. Daylight utilization has a significant impact on decreasing energy consumption in residential buildings. Residents are deprived of natural daylight when there is no attention to the design based on daylight. Iranian traditional architects use practical and straightforward methods in constructing courtyards houses to provide comfort conditions in unique rooms in courtyard houses in terms of daylight quality. In this research, the daylight quality of five separate rooms around the courtyard of Yazdanpanah's house was investigated through an experimental method. Average work plane illuminance and uniformity ratio were calculated in these rooms of the house in Kerman city, located in Iran's hot and dry climate. Findings of this research demonstrated that all rooms surrounding the courtyard of traditional houses have the ability to achieve work plane illuminance of more than acceptable value. Among all rooms around the central courtyard, one room facing the south direction achieves more than 500 Lux work plane illuminance. The amount of uniformity in this room is acceptable with more than 0.5 on most of the days in a year. The findings of this research could be used to design more comfortable rooms in contemporary houses in terms of daylight quality by creating central courtyards. doi: 10.5829/ijee.2022.13.04.01
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信