Hsing-Feng Chen, Ken-Huang Lin, Cheng-Chang Chen, Y. Tang
{"title":"一种改进的相位中心和模式匹配方法,以减少标准点法中生物轨迹校准的几何依赖性","authors":"Hsing-Feng Chen, Ken-Huang Lin, Cheng-Chang Chen, Y. Tang","doi":"10.1109/ISEMC.2005.1513479","DOIUrl":null,"url":null,"abstract":"This study proposed a modified phase center and pattern matching (PCPM) method to reduce antenna factor (AF) variations of Bilog between different geometries of standard site method (SSM). For frequencies below 300 MHz, mutual coupling may have an effect on the results of original PCPM, thereby enlarging AF variations of Bilog. Therefore, a modified PCPM was applied with the results showing that AF variations of a Bilog can be reduced by 1.8 dB after modification","PeriodicalId":6459,"journal":{"name":"2005 International Symposium on Electromagnetic Compatibility, 2005. EMC 2005.","volume":"114 1","pages":"90-92"},"PeriodicalIF":0.0000,"publicationDate":"2005-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A modified phase center and pattern matching method to reduce the geometry dependence of bilog calibration in standard site method\",\"authors\":\"Hsing-Feng Chen, Ken-Huang Lin, Cheng-Chang Chen, Y. Tang\",\"doi\":\"10.1109/ISEMC.2005.1513479\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study proposed a modified phase center and pattern matching (PCPM) method to reduce antenna factor (AF) variations of Bilog between different geometries of standard site method (SSM). For frequencies below 300 MHz, mutual coupling may have an effect on the results of original PCPM, thereby enlarging AF variations of Bilog. Therefore, a modified PCPM was applied with the results showing that AF variations of a Bilog can be reduced by 1.8 dB after modification\",\"PeriodicalId\":6459,\"journal\":{\"name\":\"2005 International Symposium on Electromagnetic Compatibility, 2005. EMC 2005.\",\"volume\":\"114 1\",\"pages\":\"90-92\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-10-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2005 International Symposium on Electromagnetic Compatibility, 2005. EMC 2005.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEMC.2005.1513479\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 International Symposium on Electromagnetic Compatibility, 2005. EMC 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.2005.1513479","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
提出了一种改进的相位中心和方向匹配(PCPM)方法,以减小标准站点法(SSM)不同几何形状之间的天线因子(AF)变化。对于低于300 MHz的频率,相互耦合可能对原始PCPM的结果产生影响,从而扩大了Bilog的AF变化。因此,应用改进的PCPM,结果表明,修改后的biog的AF变化可减少1.8 dB
A modified phase center and pattern matching method to reduce the geometry dependence of bilog calibration in standard site method
This study proposed a modified phase center and pattern matching (PCPM) method to reduce antenna factor (AF) variations of Bilog between different geometries of standard site method (SSM). For frequencies below 300 MHz, mutual coupling may have an effect on the results of original PCPM, thereby enlarging AF variations of Bilog. Therefore, a modified PCPM was applied with the results showing that AF variations of a Bilog can be reduced by 1.8 dB after modification