Ehsan Taghizadeh Tousi, R. Hashim, S. Bauk, M. Jaafar
{"title":"乳房x线造影能量范围内巨噬菌质量衰减系数和有效原子序数的评价","authors":"Ehsan Taghizadeh Tousi, R. Hashim, S. Bauk, M. Jaafar","doi":"10.9790/4861-090101100104","DOIUrl":null,"url":null,"abstract":"The potential of the Eremurus spp. root as a binder in Rhizophora-Eremurus spp. particleboard mammography phantom had been approved. In this study, the potential of Eremurus spp. as a phantom material has been investigated. The effective atomic number of the Eremurus spp. was calculated as an important parameter in the low energy range. Also, the mass attenuation coefficient of the Eremurus spp. root was measured in the 16.63 keV – 25.30 keV photon energy as a mammography range. Although, the effective atomic number of the Eremurus spp. was near to that of tissue, the mass attenuation of the Eremurus spp. root was not found close to those of breast tissue and water phantom. The results show that the Eremurus spp. root can be used just as a binder in phantom and it cannot be as a main phantom material.","PeriodicalId":14502,"journal":{"name":"IOSR Journal of Applied Physics","volume":"47 1","pages":"100-104"},"PeriodicalIF":0.0000,"publicationDate":"2017-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Evaluation of the mass attenuation coefficient and Effective Atomic Number of the Eremurus spp. Root in Mammography Energy Range\",\"authors\":\"Ehsan Taghizadeh Tousi, R. Hashim, S. Bauk, M. Jaafar\",\"doi\":\"10.9790/4861-090101100104\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The potential of the Eremurus spp. root as a binder in Rhizophora-Eremurus spp. particleboard mammography phantom had been approved. In this study, the potential of Eremurus spp. as a phantom material has been investigated. The effective atomic number of the Eremurus spp. was calculated as an important parameter in the low energy range. Also, the mass attenuation coefficient of the Eremurus spp. root was measured in the 16.63 keV – 25.30 keV photon energy as a mammography range. Although, the effective atomic number of the Eremurus spp. was near to that of tissue, the mass attenuation of the Eremurus spp. root was not found close to those of breast tissue and water phantom. The results show that the Eremurus spp. root can be used just as a binder in phantom and it cannot be as a main phantom material.\",\"PeriodicalId\":14502,\"journal\":{\"name\":\"IOSR Journal of Applied Physics\",\"volume\":\"47 1\",\"pages\":\"100-104\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IOSR Journal of Applied Physics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.9790/4861-090101100104\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IOSR Journal of Applied Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9790/4861-090101100104","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Evaluation of the mass attenuation coefficient and Effective Atomic Number of the Eremurus spp. Root in Mammography Energy Range
The potential of the Eremurus spp. root as a binder in Rhizophora-Eremurus spp. particleboard mammography phantom had been approved. In this study, the potential of Eremurus spp. as a phantom material has been investigated. The effective atomic number of the Eremurus spp. was calculated as an important parameter in the low energy range. Also, the mass attenuation coefficient of the Eremurus spp. root was measured in the 16.63 keV – 25.30 keV photon energy as a mammography range. Although, the effective atomic number of the Eremurus spp. was near to that of tissue, the mass attenuation of the Eremurus spp. root was not found close to those of breast tissue and water phantom. The results show that the Eremurus spp. root can be used just as a binder in phantom and it cannot be as a main phantom material.