通过优化SVC的位置来增强系统性能和静态安全性

K. Shanmukha Sundar, H. Ravikumar
{"title":"通过优化SVC的位置来增强系统性能和静态安全性","authors":"K. Shanmukha Sundar, H. Ravikumar","doi":"10.1109/TENCON.2008.4766799","DOIUrl":null,"url":null,"abstract":"The paper focuses on enhancement of system static security and to enhance the system performance under network contingencies through an optimal placement and optimal setting of static var compensator (SVC). The goal of the methodology developed is to alleviate/eliminate overloads on the transmission lines and to maintain the voltages at all load buses within their specified limits through an optimal placement and optimal setting of SVC under different network contingencies. The optimal location of SVC is identified by a new index called single contingency voltage sensitivity (SCVS) index. Finally the optimal setting of SVC is obtained to enhance the power system performance under network contingencies. This premise is attested on 6-bus system to show the effectiveness of the method.","PeriodicalId":22230,"journal":{"name":"TENCON 2008 - 2008 IEEE Region 10 Conference","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2008-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Enhancement of system performance and static security through an optimal placement of SVC\",\"authors\":\"K. Shanmukha Sundar, H. Ravikumar\",\"doi\":\"10.1109/TENCON.2008.4766799\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The paper focuses on enhancement of system static security and to enhance the system performance under network contingencies through an optimal placement and optimal setting of static var compensator (SVC). The goal of the methodology developed is to alleviate/eliminate overloads on the transmission lines and to maintain the voltages at all load buses within their specified limits through an optimal placement and optimal setting of SVC under different network contingencies. The optimal location of SVC is identified by a new index called single contingency voltage sensitivity (SCVS) index. Finally the optimal setting of SVC is obtained to enhance the power system performance under network contingencies. This premise is attested on 6-bus system to show the effectiveness of the method.\",\"PeriodicalId\":22230,\"journal\":{\"name\":\"TENCON 2008 - 2008 IEEE Region 10 Conference\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"TENCON 2008 - 2008 IEEE Region 10 Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TENCON.2008.4766799\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"TENCON 2008 - 2008 IEEE Region 10 Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TENCON.2008.4766799","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

本文通过对静态无功补偿器(SVC)的优化配置和优化设置,研究了在网络突发事件条件下增强系统静态安全性和提高系统性能的方法。所开发的方法的目标是减轻/消除传输线上的过载,并通过在不同网络突发事件下SVC的最佳放置和最佳设置将所有负载总线的电压保持在其规定的限制内。采用一种新的指标——单应急电压灵敏度指标,确定了SVC的最优位置。最后给出了支持向量控制的最优设置,以提高网络突发事件下电力系统的性能。在6总线系统上验证了这一前提,证明了该方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Enhancement of system performance and static security through an optimal placement of SVC
The paper focuses on enhancement of system static security and to enhance the system performance under network contingencies through an optimal placement and optimal setting of static var compensator (SVC). The goal of the methodology developed is to alleviate/eliminate overloads on the transmission lines and to maintain the voltages at all load buses within their specified limits through an optimal placement and optimal setting of SVC under different network contingencies. The optimal location of SVC is identified by a new index called single contingency voltage sensitivity (SCVS) index. Finally the optimal setting of SVC is obtained to enhance the power system performance under network contingencies. This premise is attested on 6-bus system to show the effectiveness of the method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信