术中实时成像引导的腹腔镜肝切除术

Q4 Medicine
Peng Lu, Hongguang Wang
{"title":"术中实时成像引导的腹腔镜肝切除术","authors":"Peng Lu, Hongguang Wang","doi":"10.3760/CMA.J.CN431274-20200306-00242","DOIUrl":null,"url":null,"abstract":"In recent years, laparoscopic hepatectomy has developed rapidly, but new challenges are posed to surgeons because of this surgical approach. The disadvantages of laparoscopic surgery can be effectively solved by using intraoperative real-time imaging guidance technology. Laparoscopic ultrasound can be used to discover and diagnose the nature of lesions, mark the important pipeline structure, determine the cutting edge, and guide puncture. ICG fluorescence imaging can be applied to the identification, localization, characterization of intraoperative lesions, the marking of specific liver segments and the prevention of postoperative bile leakage. These two technologies are the only two real-time imaging guidance technologies in laparoscopic hepatectomy at present, which truly make up for the shortcomings of laparoscopic liver surgery such as the inability to palpate and limited exploration exposure. \n \nKey words: \nLaparoscopy; Hepatectomy; Surgery, image-guided","PeriodicalId":15276,"journal":{"name":"中国医师杂志","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Intraoperative real-time imaging-guided laparoscopic liver resection\",\"authors\":\"Peng Lu, Hongguang Wang\",\"doi\":\"10.3760/CMA.J.CN431274-20200306-00242\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In recent years, laparoscopic hepatectomy has developed rapidly, but new challenges are posed to surgeons because of this surgical approach. The disadvantages of laparoscopic surgery can be effectively solved by using intraoperative real-time imaging guidance technology. Laparoscopic ultrasound can be used to discover and diagnose the nature of lesions, mark the important pipeline structure, determine the cutting edge, and guide puncture. ICG fluorescence imaging can be applied to the identification, localization, characterization of intraoperative lesions, the marking of specific liver segments and the prevention of postoperative bile leakage. These two technologies are the only two real-time imaging guidance technologies in laparoscopic hepatectomy at present, which truly make up for the shortcomings of laparoscopic liver surgery such as the inability to palpate and limited exploration exposure. \\n \\nKey words: \\nLaparoscopy; Hepatectomy; Surgery, image-guided\",\"PeriodicalId\":15276,\"journal\":{\"name\":\"中国医师杂志\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-03-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中国医师杂志\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3760/CMA.J.CN431274-20200306-00242\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国医师杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/CMA.J.CN431274-20200306-00242","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

近年来,腹腔镜肝切除术发展迅速,但这种手术方式给外科医生带来了新的挑战。采用术中实时成像引导技术,可以有效解决腹腔镜手术的缺点。腹腔镜超声可以发现和诊断病变的性质,标记重要的管道结构,确定切口,指导穿刺。ICG荧光成像可用于术中病变的识别、定位、表征、特定肝段的标记及术后胆漏的预防。这两种技术是目前腹腔镜肝切除术中仅有的两种实时成像引导技术,真正弥补了腹腔镜肝手术无法触诊、探查暴露受限等缺点。关键词:腹腔镜;肝切除术;手术导航下
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Intraoperative real-time imaging-guided laparoscopic liver resection
In recent years, laparoscopic hepatectomy has developed rapidly, but new challenges are posed to surgeons because of this surgical approach. The disadvantages of laparoscopic surgery can be effectively solved by using intraoperative real-time imaging guidance technology. Laparoscopic ultrasound can be used to discover and diagnose the nature of lesions, mark the important pipeline structure, determine the cutting edge, and guide puncture. ICG fluorescence imaging can be applied to the identification, localization, characterization of intraoperative lesions, the marking of specific liver segments and the prevention of postoperative bile leakage. These two technologies are the only two real-time imaging guidance technologies in laparoscopic hepatectomy at present, which truly make up for the shortcomings of laparoscopic liver surgery such as the inability to palpate and limited exploration exposure. Key words: Laparoscopy; Hepatectomy; Surgery, image-guided
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
中国医师杂志
中国医师杂志 Medicine-Medicine (all)
CiteScore
0.10
自引率
0.00%
发文量
20937
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信