Houman Teymourian, Firooz Maddadi, S. Khorasanizadeh, Atieh Tizghadam, Hamidreza Azizi Faresani, F. Behnaz, Masih Ebrahimi Dehkordi
{"title":"气管插管袖口疝术后全身麻醉异常气道阻塞病例报告","authors":"Houman Teymourian, Firooz Maddadi, S. Khorasanizadeh, Atieh Tizghadam, Hamidreza Azizi Faresani, F. Behnaz, Masih Ebrahimi Dehkordi","doi":"10.22037/NBM.V9I3.33789","DOIUrl":null,"url":null,"abstract":"Abstract \nBackground: Airway management is always of great concern for anesthesiologists especially in the prone position. Utilizing an Armored endotracheal tube is considered to be safe in such patients. \nCases Report: In this current case, we introduce a patient undergoing a wake-up test during spinal surgery who suffered from hypoventilation at the end of surgery. His condition improved only after extubation. After extubation, we confronted a herniated cuff that was not deflated, although we tried twice. We concluded that the patient's respiratory effort against obstructed airway produced a negative pressure, which made the cuff herniated, resulting in airway obstruction. Moreover, the patient biting the tube during the wake-up test damaged the tube and cuff deflation pathway. \nConclusion: It is important to consider cuff herniation as a cause of obstruction when other possible etiologies are ruled out.","PeriodicalId":19372,"journal":{"name":"Novelty in Biomedicine","volume":"39 1","pages":"145-148"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Unusual Airway Obstruction during General Anesthesia following Endotracheal Tube Cuff Herniation; A Case Report\",\"authors\":\"Houman Teymourian, Firooz Maddadi, S. Khorasanizadeh, Atieh Tizghadam, Hamidreza Azizi Faresani, F. Behnaz, Masih Ebrahimi Dehkordi\",\"doi\":\"10.22037/NBM.V9I3.33789\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract \\nBackground: Airway management is always of great concern for anesthesiologists especially in the prone position. Utilizing an Armored endotracheal tube is considered to be safe in such patients. \\nCases Report: In this current case, we introduce a patient undergoing a wake-up test during spinal surgery who suffered from hypoventilation at the end of surgery. His condition improved only after extubation. After extubation, we confronted a herniated cuff that was not deflated, although we tried twice. We concluded that the patient's respiratory effort against obstructed airway produced a negative pressure, which made the cuff herniated, resulting in airway obstruction. Moreover, the patient biting the tube during the wake-up test damaged the tube and cuff deflation pathway. \\nConclusion: It is important to consider cuff herniation as a cause of obstruction when other possible etiologies are ruled out.\",\"PeriodicalId\":19372,\"journal\":{\"name\":\"Novelty in Biomedicine\",\"volume\":\"39 1\",\"pages\":\"145-148\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-08-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Novelty in Biomedicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22037/NBM.V9I3.33789\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Novelty in Biomedicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22037/NBM.V9I3.33789","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Unusual Airway Obstruction during General Anesthesia following Endotracheal Tube Cuff Herniation; A Case Report
Abstract
Background: Airway management is always of great concern for anesthesiologists especially in the prone position. Utilizing an Armored endotracheal tube is considered to be safe in such patients.
Cases Report: In this current case, we introduce a patient undergoing a wake-up test during spinal surgery who suffered from hypoventilation at the end of surgery. His condition improved only after extubation. After extubation, we confronted a herniated cuff that was not deflated, although we tried twice. We concluded that the patient's respiratory effort against obstructed airway produced a negative pressure, which made the cuff herniated, resulting in airway obstruction. Moreover, the patient biting the tube during the wake-up test damaged the tube and cuff deflation pathway.
Conclusion: It is important to consider cuff herniation as a cause of obstruction when other possible etiologies are ruled out.