计算机辅助全膝关节成形术的手术。与种植体最终对齐相关的因素

Daniel Hernandez-Vaquero, Alfonso Noriega-Fernandez, Abelardo Suarez-Vazquez, Manuel A. Sandoval-Garcia, Andres A. Sierra-Pereira, Laura Gil-Martinez, Jose Manuel Fernandez-Carreira
{"title":"计算机辅助全膝关节成形术的手术。与种植体最终对齐相关的因素","authors":"Daniel Hernandez-Vaquero,&nbsp;Alfonso Noriega-Fernandez,&nbsp;Abelardo Suarez-Vazquez,&nbsp;Manuel A. Sandoval-Garcia,&nbsp;Andres A. Sierra-Pereira,&nbsp;Laura Gil-Martinez,&nbsp;Jose Manuel Fernandez-Carreira","doi":"10.1016/j.rslaot.2017.02.009","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>To know the results of a total knee arthroplasty series performed with surgical navigation in frontal angulation and final rotation of the knee at both 0° and 90° of flexion and to study the influence on these results of certain factors such as body mass index, minimal invasive surgery and computer navigation software.</p></div><div><h3>Material and methods</h3><p>A study was carried out on a personal series of 145 total knee arthroplasty operated with a wireless system of computer assisted surgery. The results have been graded taking into account the frontal angulation of the mechanical axis and the final rotation of the limb at 0° and at 90° of flexion. The data has been collected from the computer system database. A descriptive analysis of the series has been made, also studying the influence on the final results of certain factors.</p></div><div><h3>Results</h3><p>The final alignment obtained in the whole series is close to the ideal situation regarding the angulation of the limb in frontal position (0°<!--> <!-->±<!--> <!-->3°), although a slight residual deviation in varus is appreciable (less than 1°). No differences were found in the final results in relation to the different software systems used, neither with the body mass index nor with the type of surgery (minimal invasive surgery vs standard surgery).</p></div><div><h3>Conclusions</h3><p>Results regarding the front mechanical axis of the knee replacements performed with surgical navigation are not changed depending on the factors studied.</p></div>","PeriodicalId":101114,"journal":{"name":"Revista Latinoamericana de Cirugía Ortopédica","volume":"1 4","pages":"Pages 128-134"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.rslaot.2017.02.009","citationCount":"1","resultStr":"{\"title\":\"Cirugía asistida con ordenador en las artroplastias totales de rodilla. Factores relacionados con la alineación final del implante\",\"authors\":\"Daniel Hernandez-Vaquero,&nbsp;Alfonso Noriega-Fernandez,&nbsp;Abelardo Suarez-Vazquez,&nbsp;Manuel A. Sandoval-Garcia,&nbsp;Andres A. Sierra-Pereira,&nbsp;Laura Gil-Martinez,&nbsp;Jose Manuel Fernandez-Carreira\",\"doi\":\"10.1016/j.rslaot.2017.02.009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objective</h3><p>To know the results of a total knee arthroplasty series performed with surgical navigation in frontal angulation and final rotation of the knee at both 0° and 90° of flexion and to study the influence on these results of certain factors such as body mass index, minimal invasive surgery and computer navigation software.</p></div><div><h3>Material and methods</h3><p>A study was carried out on a personal series of 145 total knee arthroplasty operated with a wireless system of computer assisted surgery. The results have been graded taking into account the frontal angulation of the mechanical axis and the final rotation of the limb at 0° and at 90° of flexion. The data has been collected from the computer system database. A descriptive analysis of the series has been made, also studying the influence on the final results of certain factors.</p></div><div><h3>Results</h3><p>The final alignment obtained in the whole series is close to the ideal situation regarding the angulation of the limb in frontal position (0°<!--> <!-->±<!--> <!-->3°), although a slight residual deviation in varus is appreciable (less than 1°). No differences were found in the final results in relation to the different software systems used, neither with the body mass index nor with the type of surgery (minimal invasive surgery vs standard surgery).</p></div><div><h3>Conclusions</h3><p>Results regarding the front mechanical axis of the knee replacements performed with surgical navigation are not changed depending on the factors studied.</p></div>\",\"PeriodicalId\":101114,\"journal\":{\"name\":\"Revista Latinoamericana de Cirugía Ortopédica\",\"volume\":\"1 4\",\"pages\":\"Pages 128-134\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.rslaot.2017.02.009\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista Latinoamericana de Cirugía Ortopédica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2444972517300153\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Latinoamericana de Cirugía Ortopédica","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2444972517300153","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

目的了解在0°和90°屈曲位置行全膝关节成形术系列手术导航的结果,并探讨体重指数、微创手术和计算机导航软件等因素对结果的影响。材料与方法采用无线计算机辅助手术系统对145例个人全膝关节置换术进行了研究。考虑到机械轴的正面角度和肢体在0°和90°屈曲时的最终旋转,结果已经分级。数据已从计算机系统数据库中收集。对该系列进行了描述性分析,并研究了某些因素对最终结果的影响。结果整个系列的最终对中结果接近于肢体正面角度的理想情况(0°±3°),尽管内翻有轻微的残余偏差(小于1°)。最终结果与使用的不同软件系统无关,无论是体重指数还是手术类型(微创手术与标准手术)都没有差异。结论导航行膝关节置换术前机械轴的结果不会因研究的因素而改变。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Cirugía asistida con ordenador en las artroplastias totales de rodilla. Factores relacionados con la alineación final del implante

Objective

To know the results of a total knee arthroplasty series performed with surgical navigation in frontal angulation and final rotation of the knee at both 0° and 90° of flexion and to study the influence on these results of certain factors such as body mass index, minimal invasive surgery and computer navigation software.

Material and methods

A study was carried out on a personal series of 145 total knee arthroplasty operated with a wireless system of computer assisted surgery. The results have been graded taking into account the frontal angulation of the mechanical axis and the final rotation of the limb at 0° and at 90° of flexion. The data has been collected from the computer system database. A descriptive analysis of the series has been made, also studying the influence on the final results of certain factors.

Results

The final alignment obtained in the whole series is close to the ideal situation regarding the angulation of the limb in frontal position (0° ± 3°), although a slight residual deviation in varus is appreciable (less than 1°). No differences were found in the final results in relation to the different software systems used, neither with the body mass index nor with the type of surgery (minimal invasive surgery vs standard surgery).

Conclusions

Results regarding the front mechanical axis of the knee replacements performed with surgical navigation are not changed depending on the factors studied.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信