{"title":"一种新型中压电力电缆诊断系统的研制","authors":"D. Yi, Sang-Bae Park, Soo-Won Lim","doi":"10.1109/ELINSL.2002.995980","DOIUrl":null,"url":null,"abstract":"We have developed the global assessment system for medium voltage power cable systems. Our purpose of diagnostic activity is the economic discrimination and maintenance of bad cables, which is likely to cause cable system failure. We have adopted the aging time constant method to construct the power cable assessment system for our diagnostic purpose. From the field application test results, we have concluded that our system is successful and convenient for the discrimination and maintenance of the bad cables economically.","PeriodicalId":10532,"journal":{"name":"Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316)","volume":"26 1","pages":"485-487"},"PeriodicalIF":0.0000,"publicationDate":"2002-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A new cable diagnosis system development for MV power cables\",\"authors\":\"D. Yi, Sang-Bae Park, Soo-Won Lim\",\"doi\":\"10.1109/ELINSL.2002.995980\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We have developed the global assessment system for medium voltage power cable systems. Our purpose of diagnostic activity is the economic discrimination and maintenance of bad cables, which is likely to cause cable system failure. We have adopted the aging time constant method to construct the power cable assessment system for our diagnostic purpose. From the field application test results, we have concluded that our system is successful and convenient for the discrimination and maintenance of the bad cables economically.\",\"PeriodicalId\":10532,\"journal\":{\"name\":\"Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316)\",\"volume\":\"26 1\",\"pages\":\"485-487\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-04-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ELINSL.2002.995980\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELINSL.2002.995980","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A new cable diagnosis system development for MV power cables
We have developed the global assessment system for medium voltage power cable systems. Our purpose of diagnostic activity is the economic discrimination and maintenance of bad cables, which is likely to cause cable system failure. We have adopted the aging time constant method to construct the power cable assessment system for our diagnostic purpose. From the field application test results, we have concluded that our system is successful and convenient for the discrimination and maintenance of the bad cables economically.