{"title":"Na2FeO4同步氧化处理EDTA-CU废水的缩回实验研究","authors":"Jiang Dayong, Wang Xuanjun, L. Shuguang, Wang Wenguo","doi":"10.1109/ICBBE.2011.5780974","DOIUrl":null,"url":null,"abstract":"As the Cu2+ in EDTA-Cu wastewater has too high concentration to remove with general method and is in a complex state, and its handling is the difficult part in environmental engineering, we try to use synchronous Oxidation Treatment in EDTA-Cu wastewater with high ferrite salt and have achieved good results. Preparation of Na2FeO4 as an oxidant on the spot can not only solve the problem of high cost, but simplify the process of disposal. Measured by the removal rates of Cu2+ as criteria, the effect of three important factors are studied, including ph, dosage and reaction time, then corresponding optimal parameters can be acquired by the orthogonal test. The results show that the removal rate of Cu2+ can be up to 99.1% in such experimental conditions that pH=14, reaction time = 30min and dosage = 300mg/L, and the concentration of Cu2+ is less than 0.49mg/L in the treated wastewater, which also meets the national discharge standards of class I.","PeriodicalId":6438,"journal":{"name":"2011 5th International Conference on Bioinformatics and Biomedical Engineering","volume":"10 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2011-05-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Notice of RetractionExperiment Study on the Oxidation Treatment of EDTA-CU Wastewater by Na2FeO4 Synchronous\",\"authors\":\"Jiang Dayong, Wang Xuanjun, L. Shuguang, Wang Wenguo\",\"doi\":\"10.1109/ICBBE.2011.5780974\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"As the Cu2+ in EDTA-Cu wastewater has too high concentration to remove with general method and is in a complex state, and its handling is the difficult part in environmental engineering, we try to use synchronous Oxidation Treatment in EDTA-Cu wastewater with high ferrite salt and have achieved good results. Preparation of Na2FeO4 as an oxidant on the spot can not only solve the problem of high cost, but simplify the process of disposal. Measured by the removal rates of Cu2+ as criteria, the effect of three important factors are studied, including ph, dosage and reaction time, then corresponding optimal parameters can be acquired by the orthogonal test. The results show that the removal rate of Cu2+ can be up to 99.1% in such experimental conditions that pH=14, reaction time = 30min and dosage = 300mg/L, and the concentration of Cu2+ is less than 0.49mg/L in the treated wastewater, which also meets the national discharge standards of class I.\",\"PeriodicalId\":6438,\"journal\":{\"name\":\"2011 5th International Conference on Bioinformatics and Biomedical Engineering\",\"volume\":\"10 1\",\"pages\":\"1-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-05-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 5th International Conference on Bioinformatics and Biomedical Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICBBE.2011.5780974\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 5th International Conference on Bioinformatics and Biomedical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICBBE.2011.5780974","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

由于EDTA-Cu废水中的Cu2+浓度过高,难以用一般方法去除,且状态复杂,处理是环境工程中的难点,我们尝试对高铁氧体盐EDTA-Cu废水进行同步氧化处理,取得了较好的效果。现场制备Na2FeO4作为氧化剂,既解决了成本高的问题,又简化了处理过程。以Cu2+的去除率为指标,考察了ph、投加量和反应时间三个重要因素的影响,并通过正交试验得出了相应的最佳工艺参数。结果表明,在pH=14、反应时间= 30min、投加量= 300mg/L的实验条件下,处理后的废水中Cu2+的浓度小于0.49mg/L, Cu2+的去除率可达99.1%,达到国家一级排放标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Notice of RetractionExperiment Study on the Oxidation Treatment of EDTA-CU Wastewater by Na2FeO4 Synchronous
As the Cu2+ in EDTA-Cu wastewater has too high concentration to remove with general method and is in a complex state, and its handling is the difficult part in environmental engineering, we try to use synchronous Oxidation Treatment in EDTA-Cu wastewater with high ferrite salt and have achieved good results. Preparation of Na2FeO4 as an oxidant on the spot can not only solve the problem of high cost, but simplify the process of disposal. Measured by the removal rates of Cu2+ as criteria, the effect of three important factors are studied, including ph, dosage and reaction time, then corresponding optimal parameters can be acquired by the orthogonal test. The results show that the removal rate of Cu2+ can be up to 99.1% in such experimental conditions that pH=14, reaction time = 30min and dosage = 300mg/L, and the concentration of Cu2+ is less than 0.49mg/L in the treated wastewater, which also meets the national discharge standards of class I.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信