声场测试条件下韩语矩阵句噪声识别的重测信度

Q3 Medicine
Yukyeong Jung, J. Han, Seok-Ju Choi, J. Lee
{"title":"声场测试条件下韩语矩阵句噪声识别的重测信度","authors":"Yukyeong Jung, J. Han, Seok-Ju Choi, J. Lee","doi":"10.21848/asr.210037","DOIUrl":null,"url":null,"abstract":"Purpose: This study aimed to measure the test-retest reliability of the Korean Matrix sentence-in-noise test in a sound-field testing condition.Methods: Fifty-five listeners with normal hearing participated. The sound-field speech-in-noise test was administered with a front loudspeaker by presenting noise at a fixed level (65 dB SPL) while adaptively adjusting the sentence level based on the listener’s response. The speech reception thresholds (SRTs) corresponding to 50% sentence-in-noise intelligibility were obtained using speech-shaped noise (SSN), International Collegium of Rehabilitative Audiology (ICRA) noise, and International Speech Test Signal (ISTS) noise. For the test-retest reliability, each subject was tested twice in a 2-week interval. The test-retest reliabilities were judged by the intraclass correlation coefficient (ICC), the minimal detectable change (MDC) values, and Bland-Altman plots.Results: The test-retest reliabilities of the Korean Matrix sentence test were good (ICC, 0.84~0.86) across SSN, ICRA, ISTS noises. The MDC was 0.92 dB SNR for SSN and 2.83 and 2.98 dB SNR for ICRA and ISTS, indicating the random measurement error varied across the types of noise.Conclusion: The Korean Matrix sentence-in-noise test can be used as a reliable tool to assess speech-in-noise intelligibility in sound-field testing condition. Further study across various sessions would strengthen the present finding.","PeriodicalId":36841,"journal":{"name":"Audiology and Speech Research","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Test-retest Reliability of the Korean Matrix Sentence-in-noise Recognition in Sound-field Testing Condition\",\"authors\":\"Yukyeong Jung, J. Han, Seok-Ju Choi, J. Lee\",\"doi\":\"10.21848/asr.210037\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose: This study aimed to measure the test-retest reliability of the Korean Matrix sentence-in-noise test in a sound-field testing condition.Methods: Fifty-five listeners with normal hearing participated. The sound-field speech-in-noise test was administered with a front loudspeaker by presenting noise at a fixed level (65 dB SPL) while adaptively adjusting the sentence level based on the listener’s response. The speech reception thresholds (SRTs) corresponding to 50% sentence-in-noise intelligibility were obtained using speech-shaped noise (SSN), International Collegium of Rehabilitative Audiology (ICRA) noise, and International Speech Test Signal (ISTS) noise. For the test-retest reliability, each subject was tested twice in a 2-week interval. The test-retest reliabilities were judged by the intraclass correlation coefficient (ICC), the minimal detectable change (MDC) values, and Bland-Altman plots.Results: The test-retest reliabilities of the Korean Matrix sentence test were good (ICC, 0.84~0.86) across SSN, ICRA, ISTS noises. The MDC was 0.92 dB SNR for SSN and 2.83 and 2.98 dB SNR for ICRA and ISTS, indicating the random measurement error varied across the types of noise.Conclusion: The Korean Matrix sentence-in-noise test can be used as a reliable tool to assess speech-in-noise intelligibility in sound-field testing condition. Further study across various sessions would strengthen the present finding.\",\"PeriodicalId\":36841,\"journal\":{\"name\":\"Audiology and Speech Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Audiology and Speech Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21848/asr.210037\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Audiology and Speech Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21848/asr.210037","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 2

摘要

目的:在声场测试条件下,考察朝鲜语矩阵噪声句子测试的重测信度。方法:55名听力正常的听者参与。声场噪声中的语音测试采用前置扬声器,以固定水平(65 dB SPL)呈现噪声,同时根据听者的反应自适应调整句子水平。采用语音形状噪声(SSN)、国际康复听力学学会(ICRA)噪声和国际语音测试信号(ISTS)噪声获得了50%句子可理解度对应的语音接收阈值(srt)。对于重测信度,每个被试以2周为间隔进行两次测试。通过类内相关系数(ICC)、最小可检测变化(MDC)值和Bland-Altman图判断重测信度。结果:朝鲜语矩阵句检验在SSN、ICRA、ISTS噪声下的重测信度为0.84~0.86。SSN的最小信噪比为0.92 dB, ICRA和ist的最小信噪比分别为2.83和2.98 dB,表明随机测量误差随噪声类型的不同而变化。结论:在声场测试条件下,朝鲜语矩阵噪声句子测试可作为评价噪声语音可理解性的可靠工具。在各届会议期间的进一步研究将加强目前的结论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Test-retest Reliability of the Korean Matrix Sentence-in-noise Recognition in Sound-field Testing Condition
Purpose: This study aimed to measure the test-retest reliability of the Korean Matrix sentence-in-noise test in a sound-field testing condition.Methods: Fifty-five listeners with normal hearing participated. The sound-field speech-in-noise test was administered with a front loudspeaker by presenting noise at a fixed level (65 dB SPL) while adaptively adjusting the sentence level based on the listener’s response. The speech reception thresholds (SRTs) corresponding to 50% sentence-in-noise intelligibility were obtained using speech-shaped noise (SSN), International Collegium of Rehabilitative Audiology (ICRA) noise, and International Speech Test Signal (ISTS) noise. For the test-retest reliability, each subject was tested twice in a 2-week interval. The test-retest reliabilities were judged by the intraclass correlation coefficient (ICC), the minimal detectable change (MDC) values, and Bland-Altman plots.Results: The test-retest reliabilities of the Korean Matrix sentence test were good (ICC, 0.84~0.86) across SSN, ICRA, ISTS noises. The MDC was 0.92 dB SNR for SSN and 2.83 and 2.98 dB SNR for ICRA and ISTS, indicating the random measurement error varied across the types of noise.Conclusion: The Korean Matrix sentence-in-noise test can be used as a reliable tool to assess speech-in-noise intelligibility in sound-field testing condition. Further study across various sessions would strengthen the present finding.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Audiology and Speech Research
Audiology and Speech Research Medicine-Otorhinolaryngology
CiteScore
0.70
自引率
0.00%
发文量
29
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信