H. El-Said, S. El-Deen, M. Aydia, M. El-Naggar, K. M. El-Azony
{"title":"ZrSiW吸附113Sn, 125Sb和60Co的制备及质量控制:探测器标定的体积和平面参考源","authors":"H. El-Said, S. El-Deen, M. Aydia, M. El-Naggar, K. M. El-Azony","doi":"10.21608/EJRSA.2019.12489.1069","DOIUrl":null,"url":null,"abstract":"NEUTRON activation of tin metal and cobalt chloride targets for production of 113Sn and 125Sb and 60Co was carried out in Egypt’s Second Research Reactor (ETRR-2). The 113Sn, 125Sb and 60Co were loaded onto zirconium silicotungestate gel matrix from aqueous solution at pH 1 by the batch technique. The results obtained during the adsorption process of radionuclides were explained through the Visual MINTEQ program version 3. Then 1 and 0.1g of 113Sn. 125Sb and 60Co-ZrSiW were packed into the volume and planar sealed sources, made of Chinese Artelon, respectively. The radioactivity levels of 113Sn, 125Sb and 60Co were measured and found to be (2.96±0.26, 2.22±0.26, 0.74±0.074kBq) and (0.3±0.03, 026±0.03, 0.11±0.01kBq) for the volume and planar sealed source, respectively, on 27 June 2018. The efficiency curves for the two sealed sources were determined in the energy range 36-1332.5keV, which were measured at 5cm from the HPGe-detector to determine the radioactivity levels of unknown samples for the neutron activation method.","PeriodicalId":11658,"journal":{"name":"Egyptian Journal of Radiation Sciences and Applications","volume":"5 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Preparation and Quality Control on 113Sn, 125Sb and 60Co Adsorbed on ZrSiW: Volume and Planar Reference Source for -Detector Calibration\",\"authors\":\"H. El-Said, S. El-Deen, M. Aydia, M. El-Naggar, K. M. El-Azony\",\"doi\":\"10.21608/EJRSA.2019.12489.1069\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"NEUTRON activation of tin metal and cobalt chloride targets for production of 113Sn and 125Sb and 60Co was carried out in Egypt’s Second Research Reactor (ETRR-2). The 113Sn, 125Sb and 60Co were loaded onto zirconium silicotungestate gel matrix from aqueous solution at pH 1 by the batch technique. The results obtained during the adsorption process of radionuclides were explained through the Visual MINTEQ program version 3. Then 1 and 0.1g of 113Sn. 125Sb and 60Co-ZrSiW were packed into the volume and planar sealed sources, made of Chinese Artelon, respectively. The radioactivity levels of 113Sn, 125Sb and 60Co were measured and found to be (2.96±0.26, 2.22±0.26, 0.74±0.074kBq) and (0.3±0.03, 026±0.03, 0.11±0.01kBq) for the volume and planar sealed source, respectively, on 27 June 2018. The efficiency curves for the two sealed sources were determined in the energy range 36-1332.5keV, which were measured at 5cm from the HPGe-detector to determine the radioactivity levels of unknown samples for the neutron activation method.\",\"PeriodicalId\":11658,\"journal\":{\"name\":\"Egyptian Journal of Radiation Sciences and Applications\",\"volume\":\"5 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-08-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Egyptian Journal of Radiation Sciences and Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21608/EJRSA.2019.12489.1069\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Egyptian Journal of Radiation Sciences and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/EJRSA.2019.12489.1069","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Preparation and Quality Control on 113Sn, 125Sb and 60Co Adsorbed on ZrSiW: Volume and Planar Reference Source for -Detector Calibration
NEUTRON activation of tin metal and cobalt chloride targets for production of 113Sn and 125Sb and 60Co was carried out in Egypt’s Second Research Reactor (ETRR-2). The 113Sn, 125Sb and 60Co were loaded onto zirconium silicotungestate gel matrix from aqueous solution at pH 1 by the batch technique. The results obtained during the adsorption process of radionuclides were explained through the Visual MINTEQ program version 3. Then 1 and 0.1g of 113Sn. 125Sb and 60Co-ZrSiW were packed into the volume and planar sealed sources, made of Chinese Artelon, respectively. The radioactivity levels of 113Sn, 125Sb and 60Co were measured and found to be (2.96±0.26, 2.22±0.26, 0.74±0.074kBq) and (0.3±0.03, 026±0.03, 0.11±0.01kBq) for the volume and planar sealed source, respectively, on 27 June 2018. The efficiency curves for the two sealed sources were determined in the energy range 36-1332.5keV, which were measured at 5cm from the HPGe-detector to determine the radioactivity levels of unknown samples for the neutron activation method.