K. M. Robinson, J. Garton, R. E. Punnett
{"title":"德克萨斯湖局部脱层","authors":"K. M. Robinson, J. Garton, R. E. Punnett","doi":"10.1061/JEEGAV.0001323","DOIUrl":null,"url":null,"abstract":"An axial flow Garton Pump was used to improve release water quality from Lake Texoma during thermal stratification. An 8-ft (2.44m) diam propeller pump, mounted on a floating support platform, was operated directly over the intake structure. The propeller, suspended 5.6 ft (1.7m) below the water surface, pumped high quality epilimnion water down to the outlet. Water quality parameters were monitored with and without pumping at several release rates to determine pump effectiveness. A maximum dilution factor of 32.5% was obtained at a pumping to release rate ratio of 0.48. The maximum observed improvements for turbidity, sulfides, manganese, total iron, phosphorous, and ammonia nitrogen were 83, 68, 49, 21, 53, and 37% respectively.","PeriodicalId":17335,"journal":{"name":"Journal of the Environmental Engineering Division","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1982-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Localized Destratification at Lake Texoma\",\"authors\":\"K. M. Robinson, J. Garton, R. E. Punnett\",\"doi\":\"10.1061/JEEGAV.0001323\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An axial flow Garton Pump was used to improve release water quality from Lake Texoma during thermal stratification. An 8-ft (2.44m) diam propeller pump, mounted on a floating support platform, was operated directly over the intake structure. The propeller, suspended 5.6 ft (1.7m) below the water surface, pumped high quality epilimnion water down to the outlet. Water quality parameters were monitored with and without pumping at several release rates to determine pump effectiveness. A maximum dilution factor of 32.5% was obtained at a pumping to release rate ratio of 0.48. The maximum observed improvements for turbidity, sulfides, manganese, total iron, phosphorous, and ammonia nitrogen were 83, 68, 49, 21, 53, and 37% respectively.\",\"PeriodicalId\":17335,\"journal\":{\"name\":\"Journal of the Environmental Engineering Division\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1982-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Environmental Engineering Division\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1061/JEEGAV.0001323\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Environmental Engineering Division","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1061/JEEGAV.0001323","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

采用轴流加顿泵改善得克萨斯湖热分层过程中的放水水质。直径8英尺(2.44米)的螺旋桨泵安装在浮动支撑平台上,直接在进气结构上运行。悬浮在水面5.6英尺(1.7米)以下的螺旋桨将高质量的脱毛水泵入出口。在有泵和没有泵的情况下,以几种释放速率监测水质参数,以确定泵的有效性。抽释比为0.48时,稀释系数最大可达32.5%。浊度、硫化物、锰、总铁、磷和氨氮的最大改善分别为83%、68%、49%、21%、53%和37%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Localized Destratification at Lake Texoma
An axial flow Garton Pump was used to improve release water quality from Lake Texoma during thermal stratification. An 8-ft (2.44m) diam propeller pump, mounted on a floating support platform, was operated directly over the intake structure. The propeller, suspended 5.6 ft (1.7m) below the water surface, pumped high quality epilimnion water down to the outlet. Water quality parameters were monitored with and without pumping at several release rates to determine pump effectiveness. A maximum dilution factor of 32.5% was obtained at a pumping to release rate ratio of 0.48. The maximum observed improvements for turbidity, sulfides, manganese, total iron, phosphorous, and ammonia nitrogen were 83, 68, 49, 21, 53, and 37% respectively.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信