W. Tang, L. Mei, Y. Xia, K. Ma, G. Sun, L. Tang
{"title":"新型冠状病毒肺炎感染控制现状与CT工作场所辐射安全","authors":"W. Tang, L. Mei, Y. Xia, K. Ma, G. Sun, L. Tang","doi":"10.3760/cma.j.issn.0254-5098.2021.07.007","DOIUrl":null,"url":null,"abstract":"CT is an important imaging tool for the diagnosis of novel coronavirus pneumonia (COVID-19), therefore, it's necessary to strictly control the disinfection of CT workplace and equipment and biosafety to avoid the place from becoming a potential infection source and to reduce the risk of infection of patients and radiological staff. It is also necessary to reduce the CT scan dose to minimize the radiation hazards on patients under the premise of ensuring the CT image quality and diagnostic efficiency. Based on the survey that novel coronavirus residues after disinfection at some CT workplace in domestic and overseas and the application of low-dose CT scan in diagnosis of COVID-19, as well as the current situation of radiological protection management in emergency hospital, this paper summarizes and proposes suggestions on infection control and radiological protection for CT workplace to strengthen the defense line of COVID-19 prevention and control. Copyright © 2021 by the Chinese Medical Association.","PeriodicalId":36403,"journal":{"name":"中华放射医学与防护杂志","volume":"17 1","pages":"514-518"},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Infection control status of novel coronavirus pneumonia and radiation safety at CT workplace\",\"authors\":\"W. Tang, L. Mei, Y. Xia, K. Ma, G. Sun, L. Tang\",\"doi\":\"10.3760/cma.j.issn.0254-5098.2021.07.007\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"CT is an important imaging tool for the diagnosis of novel coronavirus pneumonia (COVID-19), therefore, it's necessary to strictly control the disinfection of CT workplace and equipment and biosafety to avoid the place from becoming a potential infection source and to reduce the risk of infection of patients and radiological staff. It is also necessary to reduce the CT scan dose to minimize the radiation hazards on patients under the premise of ensuring the CT image quality and diagnostic efficiency. Based on the survey that novel coronavirus residues after disinfection at some CT workplace in domestic and overseas and the application of low-dose CT scan in diagnosis of COVID-19, as well as the current situation of radiological protection management in emergency hospital, this paper summarizes and proposes suggestions on infection control and radiological protection for CT workplace to strengthen the defense line of COVID-19 prevention and control. Copyright © 2021 by the Chinese Medical Association.\",\"PeriodicalId\":36403,\"journal\":{\"name\":\"中华放射医学与防护杂志\",\"volume\":\"17 1\",\"pages\":\"514-518\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中华放射医学与防护杂志\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3760/cma.j.issn.0254-5098.2021.07.007\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华放射医学与防护杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/cma.j.issn.0254-5098.2021.07.007","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0