{"title":"HgI2和NaI探测器效率值的比较","authors":"R. Rieppo","doi":"10.1016/0029-554X(81)90772-2","DOIUrl":null,"url":null,"abstract":"<div><p>A comparison between the absolute efficiency values of HgI<sub>2</sub> and NaI detectors has been carried out for six different source-to-detector arrangements. The HgI<sub>2</sub> and NaI detectors have been cansidered as equal in volume. Six different detector sizes and sources sizes have been used in the calculations. The calculations have been performed in the γ-ray energy region 60–1500 keV with the Monte Carlo method using a Univac 1100 computer. Water has been used as the source medium.</p></div>","PeriodicalId":100971,"journal":{"name":"Nuclear Instruments and Methods","volume":"184 2","pages":"Pages 599-601"},"PeriodicalIF":0.0000,"publicationDate":"1981-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0029-554X(81)90772-2","citationCount":"1","resultStr":"{\"title\":\"Comparison of the efficiency values of HgI2 and NaI detectors\",\"authors\":\"R. Rieppo\",\"doi\":\"10.1016/0029-554X(81)90772-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A comparison between the absolute efficiency values of HgI<sub>2</sub> and NaI detectors has been carried out for six different source-to-detector arrangements. The HgI<sub>2</sub> and NaI detectors have been cansidered as equal in volume. Six different detector sizes and sources sizes have been used in the calculations. The calculations have been performed in the γ-ray energy region 60–1500 keV with the Monte Carlo method using a Univac 1100 computer. Water has been used as the source medium.</p></div>\",\"PeriodicalId\":100971,\"journal\":{\"name\":\"Nuclear Instruments and Methods\",\"volume\":\"184 2\",\"pages\":\"Pages 599-601\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1981-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0029-554X(81)90772-2\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nuclear Instruments and Methods\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/0029554X81907722\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Instruments and Methods","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0029554X81907722","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Comparison of the efficiency values of HgI2 and NaI detectors
A comparison between the absolute efficiency values of HgI2 and NaI detectors has been carried out for six different source-to-detector arrangements. The HgI2 and NaI detectors have been cansidered as equal in volume. Six different detector sizes and sources sizes have been used in the calculations. The calculations have been performed in the γ-ray energy region 60–1500 keV with the Monte Carlo method using a Univac 1100 computer. Water has been used as the source medium.