{"title":"多室氚设施的三级安全壳","authors":"L. Kent","doi":"10.13182/FST85-A24656","DOIUrl":null,"url":null,"abstract":"An experimental system to provide tertiary containment at Mound has been upgraded to support a new multi-room tritium handling facility. This system is used to remove tritium from room air in the event of primary (process) and secondary (glovebox) containment failure. The upgraded system includes a faster response time, piping and valves that are more leaktight, and a new control panel that better indicates the system status and operating conditions.","PeriodicalId":22517,"journal":{"name":"The International journal of applied radiation and isotopes","volume":"30 1","pages":"2511-2516"},"PeriodicalIF":0.0000,"publicationDate":"1985-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Tertiary Containment in a Multi-Room Tritium Facility\",\"authors\":\"L. Kent\",\"doi\":\"10.13182/FST85-A24656\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An experimental system to provide tertiary containment at Mound has been upgraded to support a new multi-room tritium handling facility. This system is used to remove tritium from room air in the event of primary (process) and secondary (glovebox) containment failure. The upgraded system includes a faster response time, piping and valves that are more leaktight, and a new control panel that better indicates the system status and operating conditions.\",\"PeriodicalId\":22517,\"journal\":{\"name\":\"The International journal of applied radiation and isotopes\",\"volume\":\"30 1\",\"pages\":\"2511-2516\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1985-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The International journal of applied radiation and isotopes\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.13182/FST85-A24656\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of applied radiation and isotopes","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.13182/FST85-A24656","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Tertiary Containment in a Multi-Room Tritium Facility
An experimental system to provide tertiary containment at Mound has been upgraded to support a new multi-room tritium handling facility. This system is used to remove tritium from room air in the event of primary (process) and secondary (glovebox) containment failure. The upgraded system includes a faster response time, piping and valves that are more leaktight, and a new control panel that better indicates the system status and operating conditions.