{"title":"钼存在时中试多级塔传质系数的实验研究及相关性研究","authors":"M. Asadollahzadeh, M. T. Mostaedi, M. Outokesh, B. Shakib","doi":"10.30492/IJCCE.2021.111326.3705","DOIUrl":null,"url":null,"abstract":"In the present work, multistage extraction column performance for reactive separation of molybdenum from the leach aqueous phase by using D2EHPA and TBP in kerosene was investigated by using axial diffusion model. Initially, the values of initial pH and extractant concentration were optimized on the batch experiments. The variation of volumetric overall mass transfer coefficients based on continuous phase at various operating conditions was obtained. By considering the chemical reaction conditions, the experimental data indicate that the volumetric overall mass transfer coefficients increase with an enhancement in rotor speed and continuous and dispersed phase flow rates. According to the sensitivity analysis, the rotor speed and flow rate of dispersed phase have more influence on column performance. Also, the continuous flow rate has little effect on volumetric overall mass transfer coefficients. After the steady-state condition was established, the concentration profile for the extraction of molybdenum along the column was obtained. The experimental data were studied and compared with the previous models. A new model based on dimensionless numbers was derived from the evaluation of overall mass transfer coefficients with consideration of the reactive extraction system.","PeriodicalId":14572,"journal":{"name":"Iranian Journal of Chemistry & Chemical Engineering-international English Edition","volume":"183 1","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2021-07-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Experimental Study and Correlation for Mass Transfer Coefficient in the Pilot Plant Multistage Column with the Presence of Molybdenum\",\"authors\":\"M. Asadollahzadeh, M. T. Mostaedi, M. Outokesh, B. Shakib\",\"doi\":\"10.30492/IJCCE.2021.111326.3705\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the present work, multistage extraction column performance for reactive separation of molybdenum from the leach aqueous phase by using D2EHPA and TBP in kerosene was investigated by using axial diffusion model. Initially, the values of initial pH and extractant concentration were optimized on the batch experiments. The variation of volumetric overall mass transfer coefficients based on continuous phase at various operating conditions was obtained. By considering the chemical reaction conditions, the experimental data indicate that the volumetric overall mass transfer coefficients increase with an enhancement in rotor speed and continuous and dispersed phase flow rates. According to the sensitivity analysis, the rotor speed and flow rate of dispersed phase have more influence on column performance. Also, the continuous flow rate has little effect on volumetric overall mass transfer coefficients. After the steady-state condition was established, the concentration profile for the extraction of molybdenum along the column was obtained. The experimental data were studied and compared with the previous models. A new model based on dimensionless numbers was derived from the evaluation of overall mass transfer coefficients with consideration of the reactive extraction system.\",\"PeriodicalId\":14572,\"journal\":{\"name\":\"Iranian Journal of Chemistry & Chemical Engineering-international English Edition\",\"volume\":\"183 1\",\"pages\":\"\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2021-07-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iranian Journal of Chemistry & Chemical Engineering-international English Edition\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.30492/IJCCE.2021.111326.3705\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Chemistry & Chemical Engineering-international English Edition","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.30492/IJCCE.2021.111326.3705","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

采用轴向扩散模型,研究了D2EHPA和TBP在煤油中反应分离浸出水相钼的多级萃取柱性能。首先,通过批量实验优化了初始pH值和萃取剂浓度。得到了基于连续相的体积总传质系数在不同工况下的变化规律。考虑化学反应条件,实验数据表明,体积总传质系数随转子转速和连续、分散相流量的增大而增大。根据灵敏度分析,转子转速和分散相流量对塔的性能影响较大。同时,连续流量对体积总传质系数影响不大。建立稳态条件后,得到了沿柱萃取钼的浓度分布图。对实验数据进行了研究,并与以往模型进行了比较。通过对反应萃取体系总体传质系数的计算,建立了一个基于无因次数的新模型。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Experimental Study and Correlation for Mass Transfer Coefficient in the Pilot Plant Multistage Column with the Presence of Molybdenum
In the present work, multistage extraction column performance for reactive separation of molybdenum from the leach aqueous phase by using D2EHPA and TBP in kerosene was investigated by using axial diffusion model. Initially, the values of initial pH and extractant concentration were optimized on the batch experiments. The variation of volumetric overall mass transfer coefficients based on continuous phase at various operating conditions was obtained. By considering the chemical reaction conditions, the experimental data indicate that the volumetric overall mass transfer coefficients increase with an enhancement in rotor speed and continuous and dispersed phase flow rates. According to the sensitivity analysis, the rotor speed and flow rate of dispersed phase have more influence on column performance. Also, the continuous flow rate has little effect on volumetric overall mass transfer coefficients. After the steady-state condition was established, the concentration profile for the extraction of molybdenum along the column was obtained. The experimental data were studied and compared with the previous models. A new model based on dimensionless numbers was derived from the evaluation of overall mass transfer coefficients with consideration of the reactive extraction system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.80
自引率
22.20%
发文量
0
审稿时长
6-12 weeks
期刊介绍: The aim of the Iranian Journal of Chemistry and Chemical Engineering is to foster the growth of educational, scientific and Industrial Research activities among chemists and chemical engineers and to provide a medium for mutual communication and relations between Iranian academia and the industry on the one hand, and the world the scientific community on the other.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信