{"title":"室性心动过速体表制图中的QRS自动检测","authors":"J. G. C. Kemmelings, A. Linnenbank, S. Muilwijk, A. SippensGroenewegen, A. Peper, C. Grimbergen","doi":"10.1109/IEMBS.1992.5761109","DOIUrl":null,"url":null,"abstract":"A QRS detection algorithm has been developed for use in body surface mapping of ventricular tachycardia. To detect the QRS complexes the algorithm uses three computed signals: the sum of the absolute value of all leads, the sum of the absolute value of the differences of consecutive samples in all leads and, the second order derivative of the first mentioned.","PeriodicalId":6457,"journal":{"name":"1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":"88 1","pages":"561-562"},"PeriodicalIF":0.0000,"publicationDate":"1992-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Automatic QRS detection during body surface mapping of ventricular tachycardia\",\"authors\":\"J. G. C. Kemmelings, A. Linnenbank, S. Muilwijk, A. SippensGroenewegen, A. Peper, C. Grimbergen\",\"doi\":\"10.1109/IEMBS.1992.5761109\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A QRS detection algorithm has been developed for use in body surface mapping of ventricular tachycardia. To detect the QRS complexes the algorithm uses three computed signals: the sum of the absolute value of all leads, the sum of the absolute value of the differences of consecutive samples in all leads and, the second order derivative of the first mentioned.\",\"PeriodicalId\":6457,\"journal\":{\"name\":\"1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society\",\"volume\":\"88 1\",\"pages\":\"561-562\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEMBS.1992.5761109\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.1992.5761109","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

一种QRS检测算法已被开发用于室性心动过速的体表映射。为了检测QRS复合体,该算法使用三个计算信号:所有引线的绝对值之和,所有引线中连续样本的差值绝对值之和,以及第一个提到的二阶导数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Automatic QRS detection during body surface mapping of ventricular tachycardia
A QRS detection algorithm has been developed for use in body surface mapping of ventricular tachycardia. To detect the QRS complexes the algorithm uses three computed signals: the sum of the absolute value of all leads, the sum of the absolute value of the differences of consecutive samples in all leads and, the second order derivative of the first mentioned.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信