{"title":"使用视觉和热图像检测跟踪碳路径(讨论,由M. Nishida等人回复)","authors":"J. H. Mason, K. Mathes, B. Varlow, M. Nishida","doi":"10.1109/14.236203","DOIUrl":null,"url":null,"abstract":"The discussers separately address questions raised in the above-titled paper by M. Nishida et al. (ibid., vol.27, p.1050-1053, 1982) concerning tracking test procedures. The three discussers agree that there is a need to revise IEC 587. Nishida replies that the above paper did not intend to evaluate the tracking resistance of the electrical insulating materials, or to offer any information for a revision of IEC 587. >","PeriodicalId":13105,"journal":{"name":"IEEE Transactions on Electrical Insulation","volume":"16 1","pages":"425-428"},"PeriodicalIF":0.0000,"publicationDate":"1993-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Detection of tracking carbon path using visual and thermal images (Discussion, with reply by M. Nishida et al.)\",\"authors\":\"J. H. Mason, K. Mathes, B. Varlow, M. Nishida\",\"doi\":\"10.1109/14.236203\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The discussers separately address questions raised in the above-titled paper by M. Nishida et al. (ibid., vol.27, p.1050-1053, 1982) concerning tracking test procedures. The three discussers agree that there is a need to revise IEC 587. Nishida replies that the above paper did not intend to evaluate the tracking resistance of the electrical insulating materials, or to offer any information for a revision of IEC 587. >\",\"PeriodicalId\":13105,\"journal\":{\"name\":\"IEEE Transactions on Electrical Insulation\",\"volume\":\"16 1\",\"pages\":\"425-428\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Transactions on Electrical Insulation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/14.236203\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Electrical Insulation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/14.236203","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Detection of tracking carbon path using visual and thermal images (Discussion, with reply by M. Nishida et al.)
The discussers separately address questions raised in the above-titled paper by M. Nishida et al. (ibid., vol.27, p.1050-1053, 1982) concerning tracking test procedures. The three discussers agree that there is a need to revise IEC 587. Nishida replies that the above paper did not intend to evaluate the tracking resistance of the electrical insulating materials, or to offer any information for a revision of IEC 587. >