{"title":"用于抗震改造策略的建筑物地震易损性评估:快速视觉筛选法","authors":"Prabhu Agrawal, S. Jaiswal, Nishant Yadav","doi":"10.37896/ymer21.08/09","DOIUrl":null,"url":null,"abstract":"The objective of this study is to provide the assessment of the seismic vulnerability of R.C.C. and Load bearing structures by the Rapid Visual Screening Method. As Rapid Visual Screening is a preliminary stage to conducting a Simplified Vulnerability Assessment of the building.The rapid visual screening procedure requires only a visual evaluation and a few additional details. These procedures are recommended for all buildings. Rapid Visual Screening score has been evaluated for the various building which suggests further assessment for Seismic Vulnerability. India is expected to be the most populous country in the world by 2025. India has a huge volume of building stocks at present, and most of them are significantly vulnerable to earthquake hazards. In order to overcome this issue, firstly it is required to conduct the seismic vulnerability assessment at a massive scale of building stocks and buildings with a high probability of damage further evaluated with the simplified vulnerability assessment method procedures. After a detailed evaluation, it recommends a suitable retrofitting strategy. In this paper, we have studied various parameters of the Rapid Visual Screening method and the procedure to conduct it. Keywords: Seismic vulnerability, Existing Building, Simplified Vulnerability Assessment, Method, Rapid Visual Screening, Detailed vulnerability assessment.","PeriodicalId":23848,"journal":{"name":"YMER Digital","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-08-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Seismic Vulnerability Assessment of Buildings for Seismic Retrofitting Strategies: Rapid Visual Screening Method\",\"authors\":\"Prabhu Agrawal, S. Jaiswal, Nishant Yadav\",\"doi\":\"10.37896/ymer21.08/09\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The objective of this study is to provide the assessment of the seismic vulnerability of R.C.C. and Load bearing structures by the Rapid Visual Screening Method. As Rapid Visual Screening is a preliminary stage to conducting a Simplified Vulnerability Assessment of the building.The rapid visual screening procedure requires only a visual evaluation and a few additional details. These procedures are recommended for all buildings. Rapid Visual Screening score has been evaluated for the various building which suggests further assessment for Seismic Vulnerability. India is expected to be the most populous country in the world by 2025. India has a huge volume of building stocks at present, and most of them are significantly vulnerable to earthquake hazards. In order to overcome this issue, firstly it is required to conduct the seismic vulnerability assessment at a massive scale of building stocks and buildings with a high probability of damage further evaluated with the simplified vulnerability assessment method procedures. After a detailed evaluation, it recommends a suitable retrofitting strategy. In this paper, we have studied various parameters of the Rapid Visual Screening method and the procedure to conduct it. Keywords: Seismic vulnerability, Existing Building, Simplified Vulnerability Assessment, Method, Rapid Visual Screening, Detailed vulnerability assessment.\",\"PeriodicalId\":23848,\"journal\":{\"name\":\"YMER Digital\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-08-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"YMER Digital\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.37896/ymer21.08/09\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"YMER Digital","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.37896/ymer21.08/09","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究的目的是提供快速视觉筛选法评估混凝土混凝土及承重结构的地震易损性。因为快速目视筛选是对建筑物进行简易易损性评估的初步阶段。快速目视筛查程序只需要目视评估和一些额外的细节。建议所有建筑物都采用这些程序。对不同建筑进行了快速视觉筛选评分,建议对地震易损性进行进一步评估。预计到2025年,印度将成为世界上人口最多的国家。印度目前有大量的建筑存量,其中大多数都很容易受到地震的影响。为了克服这一问题,首先需要对大规模的建筑存量和损毁概率较大的建筑物进行地震易损性评估,并进一步采用简化的易损性评估方法程序进行评估。经过详细的评估,建议一个合适的改造策略。本文研究了快速目视筛选法的各参数及实施步骤。关键词:地震易损性,既有建筑,简化易损性评估,方法,快速目视筛选,详细易损性评估
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Seismic Vulnerability Assessment of Buildings for Seismic Retrofitting Strategies: Rapid Visual Screening Method
The objective of this study is to provide the assessment of the seismic vulnerability of R.C.C. and Load bearing structures by the Rapid Visual Screening Method. As Rapid Visual Screening is a preliminary stage to conducting a Simplified Vulnerability Assessment of the building.The rapid visual screening procedure requires only a visual evaluation and a few additional details. These procedures are recommended for all buildings. Rapid Visual Screening score has been evaluated for the various building which suggests further assessment for Seismic Vulnerability. India is expected to be the most populous country in the world by 2025. India has a huge volume of building stocks at present, and most of them are significantly vulnerable to earthquake hazards. In order to overcome this issue, firstly it is required to conduct the seismic vulnerability assessment at a massive scale of building stocks and buildings with a high probability of damage further evaluated with the simplified vulnerability assessment method procedures. After a detailed evaluation, it recommends a suitable retrofitting strategy. In this paper, we have studied various parameters of the Rapid Visual Screening method and the procedure to conduct it. Keywords: Seismic vulnerability, Existing Building, Simplified Vulnerability Assessment, Method, Rapid Visual Screening, Detailed vulnerability assessment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信