{"title":"用于PET线圈的检测器读出电子器件的设计和特性:用于PET/MRI的可穿透rf的TOF-PET插入","authors":"Qian Dong, I. Sacco, Chen-Ming Chang, C. Levin","doi":"10.1109/TRPMS.2023.3309771","DOIUrl":null,"url":null,"abstract":"This article presents a comprehensive description of the front-end detector readout electronics designed for positron emission tomography (PET) coil, an RF-penetrable TOF-PET insert for PET/MRI. The highly integrated front-end design is based on a mixed ASIC + FPGA approach and incorporates carefully designed power, thermal, and MR compatibility solutions. Experimental results show that the front-end design achieves excellent coincidence time resolution of <inline-formula> <tex-math notation=\"LaTeX\">$\\mathrm {238.9 \\pm 0.3 ps }$ </tex-math></inline-formula> with real-time TDC bin width calibration and energy resolution of 10.9% ± 1.1%. The results also indicate good TOF position linearity and clear energy photopeaks. Additionally, the front-end design demonstrates the capability to handle high-count rate applications, with less than <inline-formula> <tex-math notation=\"LaTeX\">$\\mathrm {0.005 \\! \\%}$ </tex-math></inline-formula> data loss or corruption observed when the count rate per SiPM channel increased from 3 to 20 kcps. The detector module temperature remained stable at <inline-formula> <tex-math notation=\"LaTeX\">$23.9{^{\\circ} }\\text{C} \\pm $ </tex-math></inline-formula> 1.3°C throughout the entire 1-h experiment. These results indicate that this front-end design is feasible for high-sensitivity TOF PET applications.","PeriodicalId":46807,"journal":{"name":"IEEE Transactions on Radiation and Plasma Medical Sciences","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design and Characterization of the Detector Readout Electronics Used in PETcoil: an RF-Penetrable TOF-PET Insert for PET/MRI\",\"authors\":\"Qian Dong, I. Sacco, Chen-Ming Chang, C. Levin\",\"doi\":\"10.1109/TRPMS.2023.3309771\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This article presents a comprehensive description of the front-end detector readout electronics designed for positron emission tomography (PET) coil, an RF-penetrable TOF-PET insert for PET/MRI. The highly integrated front-end design is based on a mixed ASIC + FPGA approach and incorporates carefully designed power, thermal, and MR compatibility solutions. Experimental results show that the front-end design achieves excellent coincidence time resolution of <inline-formula> <tex-math notation=\\\"LaTeX\\\">$\\\\mathrm {238.9 \\\\pm 0.3 ps }$ </tex-math></inline-formula> with real-time TDC bin width calibration and energy resolution of 10.9% ± 1.1%. The results also indicate good TOF position linearity and clear energy photopeaks. Additionally, the front-end design demonstrates the capability to handle high-count rate applications, with less than <inline-formula> <tex-math notation=\\\"LaTeX\\\">$\\\\mathrm {0.005 \\\\! \\\\%}$ </tex-math></inline-formula> data loss or corruption observed when the count rate per SiPM channel increased from 3 to 20 kcps. The detector module temperature remained stable at <inline-formula> <tex-math notation=\\\"LaTeX\\\">$23.9{^{\\\\circ} }\\\\text{C} \\\\pm $ </tex-math></inline-formula> 1.3°C throughout the entire 1-h experiment. These results indicate that this front-end design is feasible for high-sensitivity TOF PET applications.\",\"PeriodicalId\":46807,\"journal\":{\"name\":\"IEEE Transactions on Radiation and Plasma Medical Sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2023-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Transactions on Radiation and Plasma Medical Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TRPMS.2023.3309771\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Radiation and Plasma Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TRPMS.2023.3309771","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Design and Characterization of the Detector Readout Electronics Used in PETcoil: an RF-Penetrable TOF-PET Insert for PET/MRI
This article presents a comprehensive description of the front-end detector readout electronics designed for positron emission tomography (PET) coil, an RF-penetrable TOF-PET insert for PET/MRI. The highly integrated front-end design is based on a mixed ASIC + FPGA approach and incorporates carefully designed power, thermal, and MR compatibility solutions. Experimental results show that the front-end design achieves excellent coincidence time resolution of $\mathrm {238.9 \pm 0.3 ps }$ with real-time TDC bin width calibration and energy resolution of 10.9% ± 1.1%. The results also indicate good TOF position linearity and clear energy photopeaks. Additionally, the front-end design demonstrates the capability to handle high-count rate applications, with less than $\mathrm {0.005 \! \%}$ data loss or corruption observed when the count rate per SiPM channel increased from 3 to 20 kcps. The detector module temperature remained stable at $23.9{^{\circ} }\text{C} \pm $ 1.3°C throughout the entire 1-h experiment. These results indicate that this front-end design is feasible for high-sensitivity TOF PET applications.