离子排斥色谱法测定马血浆中总二氧化碳浓度的评价

Chin-Tong Tan
{"title":"离子排斥色谱法测定马血浆中总二氧化碳浓度的评价","authors":"Chin-Tong Tan","doi":"10.2174/1874065001307010006","DOIUrl":null,"url":null,"abstract":"Ion chromatography (IC), utilizing an ion exclusion column coupled to a conductivity detector (CD) via a post column reactor, had been evaluated for quantifying the Total Carbon dioxide (TCO2) level in equine plasma. The concentrations obtained from the analysis of the ASE linearity set correlated with the results obtained when the measurement was done using a Beckman EL-ISE ® instrument (R 2 = 0.998). Equine blood was analyzed using both instruments and the averaged absolute difference for 30 samples was 0.4 mM. The IC method was considered suitable for use to determine the compliance of 36 mM available CO2 per liter of plasma concentration threshold stated in the Malayan Racing Association's (MRA) Regulations.","PeriodicalId":90363,"journal":{"name":"The open analytical chemistry journal","volume":"11 1","pages":"6-11"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Ion Exclusion Chromatography as a Method for Determining the Total Carbon Dioxide (TCO2) Concentration in Equine Plasma\",\"authors\":\"Chin-Tong Tan\",\"doi\":\"10.2174/1874065001307010006\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Ion chromatography (IC), utilizing an ion exclusion column coupled to a conductivity detector (CD) via a post column reactor, had been evaluated for quantifying the Total Carbon dioxide (TCO2) level in equine plasma. The concentrations obtained from the analysis of the ASE linearity set correlated with the results obtained when the measurement was done using a Beckman EL-ISE ® instrument (R 2 = 0.998). Equine blood was analyzed using both instruments and the averaged absolute difference for 30 samples was 0.4 mM. The IC method was considered suitable for use to determine the compliance of 36 mM available CO2 per liter of plasma concentration threshold stated in the Malayan Racing Association's (MRA) Regulations.\",\"PeriodicalId\":90363,\"journal\":{\"name\":\"The open analytical chemistry journal\",\"volume\":\"11 1\",\"pages\":\"6-11\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-04-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The open analytical chemistry journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2174/1874065001307010006\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The open analytical chemistry journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/1874065001307010006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

离子色谱(IC),利用离子排除柱耦合电导率检测器(CD)通过柱后反应器,已经评估了用于定量马血浆中总二氧化碳(TCO2)水平。从ASE线性集分析得到的浓度与使用Beckman EL-ISE®仪器测量得到的结果相关(r2 = 0.998)。使用这两种仪器分析马的血液,30个样本的平均绝对差异为0.4毫米。IC方法被认为适合用于确定每升36毫米可用二氧化碳的血浆浓度阈值是否符合马来亚赛马协会(MRA)规定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of Ion Exclusion Chromatography as a Method for Determining the Total Carbon Dioxide (TCO2) Concentration in Equine Plasma
Ion chromatography (IC), utilizing an ion exclusion column coupled to a conductivity detector (CD) via a post column reactor, had been evaluated for quantifying the Total Carbon dioxide (TCO2) level in equine plasma. The concentrations obtained from the analysis of the ASE linearity set correlated with the results obtained when the measurement was done using a Beckman EL-ISE ® instrument (R 2 = 0.998). Equine blood was analyzed using both instruments and the averaged absolute difference for 30 samples was 0.4 mM. The IC method was considered suitable for use to determine the compliance of 36 mM available CO2 per liter of plasma concentration threshold stated in the Malayan Racing Association's (MRA) Regulations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信