不同字体大小、亮度对比和适应亮度水平下的老年人字母可读性模型

IF 2.1 3区 工程技术 Q2 CONSTRUCTION & BUILDING TECHNOLOGY
Y. Akashi, Y. Kuno, K. Murakami, M. Inatani, T. Aoki
{"title":"不同字体大小、亮度对比和适应亮度水平下的老年人字母可读性模型","authors":"Y. Akashi, Y. Kuno, K. Murakami, M. Inatani, T. Aoki","doi":"10.1177/14771535211049816","DOIUrl":null,"url":null,"abstract":"In ageing societies, it is necessary to make the visual environment more appropriate for the elderly so that they can maintain visual performance as long as possible. To this end, we aimed at developing guidelines to determine appropriate adaptation luminance and luminance contrast for given letter sizes for the elderly. In this study, we first measured the contrast sensitivities of older participants. Second, we conducted an experiment in which the same participants evaluated the degrees of readability of Japanese sentences with various letter sizes, luminance contrasts and adaptation luminances. Based on the evaluations, we developed a readability model consisting of equal-readability-level contour lines that represent the average of older peoples’ readability scores. From the model, we found we could improve readability by increasing adaptation luminance while the adaptation luminance was lower than 200 cd/m2. However, an increase in luminance contrast became more helpful to improve readability than an increase in adaptation luminance when the adaptation luminance was higher than 200 cd/m2. We also found large individual deviations in readability evaluation among older participants depending on the contrast sensitivity. We divided the participants into three groups based on their contrast sensitivity levels and compared readability models among the three groups.","PeriodicalId":18133,"journal":{"name":"Lighting Research & Technology","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2022-04-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A readability model of letters with various letter size, luminance contrast and adaptation luminance levels for seniors\",\"authors\":\"Y. Akashi, Y. Kuno, K. Murakami, M. Inatani, T. Aoki\",\"doi\":\"10.1177/14771535211049816\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In ageing societies, it is necessary to make the visual environment more appropriate for the elderly so that they can maintain visual performance as long as possible. To this end, we aimed at developing guidelines to determine appropriate adaptation luminance and luminance contrast for given letter sizes for the elderly. In this study, we first measured the contrast sensitivities of older participants. Second, we conducted an experiment in which the same participants evaluated the degrees of readability of Japanese sentences with various letter sizes, luminance contrasts and adaptation luminances. Based on the evaluations, we developed a readability model consisting of equal-readability-level contour lines that represent the average of older peoples’ readability scores. From the model, we found we could improve readability by increasing adaptation luminance while the adaptation luminance was lower than 200 cd/m2. However, an increase in luminance contrast became more helpful to improve readability than an increase in adaptation luminance when the adaptation luminance was higher than 200 cd/m2. We also found large individual deviations in readability evaluation among older participants depending on the contrast sensitivity. We divided the participants into three groups based on their contrast sensitivity levels and compared readability models among the three groups.\",\"PeriodicalId\":18133,\"journal\":{\"name\":\"Lighting Research & Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2022-04-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Lighting Research & Technology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/14771535211049816\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lighting Research & Technology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/14771535211049816","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

在老龄化社会中,有必要使视觉环境更适合老年人,使他们尽可能长时间保持视觉表现。为此,我们的目的是制定指导方针,以确定适当的适应亮度和亮度对比,为老年人给定的字母大小。在这项研究中,我们首先测量了老年参与者的对比敏感性。其次,我们进行了一项实验,在实验中,同样的参与者评估了不同字母大小、亮度对比和适应亮度的日语句子的可读性程度。在此基础上,我们建立了一个可读性模型,该模型由等可读性水平等高线组成,代表老年人可读性得分的平均值。从模型中我们发现,当适应亮度低于200 cd/m2时,可以通过提高适应亮度来提高可读性。然而,当适应亮度大于200 cd/m2时,提高亮度对比度比提高适应亮度更有利于提高可读性。我们还发现,在年龄较大的参与者中,根据对比敏感度,可读性评估存在较大的个体偏差。我们根据参与者的对比敏感度水平将他们分为三组,并比较了三组之间的可读性模型。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A readability model of letters with various letter size, luminance contrast and adaptation luminance levels for seniors
In ageing societies, it is necessary to make the visual environment more appropriate for the elderly so that they can maintain visual performance as long as possible. To this end, we aimed at developing guidelines to determine appropriate adaptation luminance and luminance contrast for given letter sizes for the elderly. In this study, we first measured the contrast sensitivities of older participants. Second, we conducted an experiment in which the same participants evaluated the degrees of readability of Japanese sentences with various letter sizes, luminance contrasts and adaptation luminances. Based on the evaluations, we developed a readability model consisting of equal-readability-level contour lines that represent the average of older peoples’ readability scores. From the model, we found we could improve readability by increasing adaptation luminance while the adaptation luminance was lower than 200 cd/m2. However, an increase in luminance contrast became more helpful to improve readability than an increase in adaptation luminance when the adaptation luminance was higher than 200 cd/m2. We also found large individual deviations in readability evaluation among older participants depending on the contrast sensitivity. We divided the participants into three groups based on their contrast sensitivity levels and compared readability models among the three groups.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Lighting Research & Technology
Lighting Research & Technology 工程技术-光学
CiteScore
5.40
自引率
16.00%
发文量
69
审稿时长
>12 weeks
期刊介绍: Lighting Research & Technology (LR&T) publishes original peer-reviewed research on all aspects of light and lighting and is published in association with The Society of Light and Lighting. LR&T covers the human response to light, the science of light generation, light control and measurement plus lighting design for both interior and exterior environments, as well as daylighting, energy efficiency and sustainability
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信