{"title":"衍生紫外可见吸收分光光度法同时测定片剂中对乙酰氨基酚和曲马多的含量","authors":"Ahmad M. El-Zinati, M. Abdel-Latif","doi":"10.2174/1874065001508010001","DOIUrl":null,"url":null,"abstract":"A comparative study of the use of first derivative zero order crossing spectra for the resolution of Paracetamol and Tramadol hydrochloride in mixtures has been achieved showing the success of the first derivative method in resolving and quantifying both compounds. Using the first derivative, rather than the second derivative, results in improved signal to noise ratio. The absorption spectra of prepared mixtures were scanned in the range of 200-500 nm. The linear concentration ranges were 25-112 and 6-48 µg mL -1 for paracetamol and Tramadol hydrochloride, respectively. The method has been successfully used for prediction of concentrations of both compounds in mixtures with good selectivity, high sensitivity and extremely low relative error. Statistical comparison was performed using t-test at 95% confidence level. There was no significant statistical difference between the results obtained by the first derivative method and the accepted values for both compounds. Also, the percentage errors were very low which adds to the merits of our work in terms of both sensitivity and accuracy.","PeriodicalId":90363,"journal":{"name":"The open analytical chemistry journal","volume":"24 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2015-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":"{\"title\":\"Simultaneous Determination of Paracetamol and Tramadol in PharmaceuticalTablets by Derivative UV-Vis Absorption Spectrophotometry\",\"authors\":\"Ahmad M. El-Zinati, M. Abdel-Latif\",\"doi\":\"10.2174/1874065001508010001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A comparative study of the use of first derivative zero order crossing spectra for the resolution of Paracetamol and Tramadol hydrochloride in mixtures has been achieved showing the success of the first derivative method in resolving and quantifying both compounds. Using the first derivative, rather than the second derivative, results in improved signal to noise ratio. The absorption spectra of prepared mixtures were scanned in the range of 200-500 nm. The linear concentration ranges were 25-112 and 6-48 µg mL -1 for paracetamol and Tramadol hydrochloride, respectively. The method has been successfully used for prediction of concentrations of both compounds in mixtures with good selectivity, high sensitivity and extremely low relative error. Statistical comparison was performed using t-test at 95% confidence level. There was no significant statistical difference between the results obtained by the first derivative method and the accepted values for both compounds. Also, the percentage errors were very low which adds to the merits of our work in terms of both sensitivity and accuracy.\",\"PeriodicalId\":90363,\"journal\":{\"name\":\"The open analytical chemistry journal\",\"volume\":\"24 1\",\"pages\":\"1-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-03-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The open analytical chemistry journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2174/1874065001508010001\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The open analytical chemistry journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/1874065001508010001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14
摘要
对一阶导数零阶交叉光谱在对乙酰氨基酚和盐酸曲马多混合物中分离的比较研究表明,一阶导数方法在分离和定量这两种化合物方面取得了成功。使用一阶导数,而不是二阶导数,可以提高信噪比。对制备的混合物在200 ~ 500 nm范围内的吸收光谱进行扫描。对乙酰氨基酚和盐酸曲马多的线性浓度范围分别为25 ~ 112和6 ~ 48µg mL -1。该方法具有选择性好、灵敏度高、相对误差极低的优点,成功地用于预测混合物中两种化合物的浓度。统计学比较采用95%置信水平的t检验。用一阶导数法得到的结果与两种化合物的公认值之间没有显著的统计学差异。此外,错误率非常低,这增加了我们的工作在灵敏度和准确性方面的优点。
Simultaneous Determination of Paracetamol and Tramadol in PharmaceuticalTablets by Derivative UV-Vis Absorption Spectrophotometry
A comparative study of the use of first derivative zero order crossing spectra for the resolution of Paracetamol and Tramadol hydrochloride in mixtures has been achieved showing the success of the first derivative method in resolving and quantifying both compounds. Using the first derivative, rather than the second derivative, results in improved signal to noise ratio. The absorption spectra of prepared mixtures were scanned in the range of 200-500 nm. The linear concentration ranges were 25-112 and 6-48 µg mL -1 for paracetamol and Tramadol hydrochloride, respectively. The method has been successfully used for prediction of concentrations of both compounds in mixtures with good selectivity, high sensitivity and extremely low relative error. Statistical comparison was performed using t-test at 95% confidence level. There was no significant statistical difference between the results obtained by the first derivative method and the accepted values for both compounds. Also, the percentage errors were very low which adds to the merits of our work in terms of both sensitivity and accuracy.