{"title":"硬膜外吊滴法“误吸”的新理论","authors":"Miyabe Masayuki","doi":"10.36959/377/371","DOIUrl":null,"url":null,"abstract":"The hanging-drop method whereby a drop of saline hanging in the hub of an epidural needle is aspirated when the needle entered the epidural space. The theory behind this maneuver has been controversial. Recently I reported this phenomenon might be explained by the release of compressed air inside of the epidural needle into the epidural space [1]. The reason why I reached this theory is that a drop of saline placed within the hub of an epidural needle is sucked in when the needle is advanced and penetrates through a polyurethane foam cube. And I also showed the pressure inside of the epidural needle increased according to the distance the needle traveled to penetrate the polyurethane foam. Furthermore, once we stop advancing the needle, the pressure inside of the needle drops to zero. This may be explained by the leakage of the air inside of the needle. This means the amount of “aspiration” of saline drop differs according to the distance of the needle tip reaches the epidural space through the ligament after advancing the needle. In this way, knowing that the degree of attraction of the saline droplet may change depending","PeriodicalId":92399,"journal":{"name":"Journal of clinical anesthesia and pain management","volume":"10 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A New Theory Explaining \\\"Aspiration\\\" in The Epidural Hanging - Drop Method\",\"authors\":\"Miyabe Masayuki\",\"doi\":\"10.36959/377/371\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The hanging-drop method whereby a drop of saline hanging in the hub of an epidural needle is aspirated when the needle entered the epidural space. The theory behind this maneuver has been controversial. Recently I reported this phenomenon might be explained by the release of compressed air inside of the epidural needle into the epidural space [1]. The reason why I reached this theory is that a drop of saline placed within the hub of an epidural needle is sucked in when the needle is advanced and penetrates through a polyurethane foam cube. And I also showed the pressure inside of the epidural needle increased according to the distance the needle traveled to penetrate the polyurethane foam. Furthermore, once we stop advancing the needle, the pressure inside of the needle drops to zero. This may be explained by the leakage of the air inside of the needle. This means the amount of “aspiration” of saline drop differs according to the distance of the needle tip reaches the epidural space through the ligament after advancing the needle. In this way, knowing that the degree of attraction of the saline droplet may change depending\",\"PeriodicalId\":92399,\"journal\":{\"name\":\"Journal of clinical anesthesia and pain management\",\"volume\":\"10 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of clinical anesthesia and pain management\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.36959/377/371\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of clinical anesthesia and pain management","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36959/377/371","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A New Theory Explaining "Aspiration" in The Epidural Hanging - Drop Method
The hanging-drop method whereby a drop of saline hanging in the hub of an epidural needle is aspirated when the needle entered the epidural space. The theory behind this maneuver has been controversial. Recently I reported this phenomenon might be explained by the release of compressed air inside of the epidural needle into the epidural space [1]. The reason why I reached this theory is that a drop of saline placed within the hub of an epidural needle is sucked in when the needle is advanced and penetrates through a polyurethane foam cube. And I also showed the pressure inside of the epidural needle increased according to the distance the needle traveled to penetrate the polyurethane foam. Furthermore, once we stop advancing the needle, the pressure inside of the needle drops to zero. This may be explained by the leakage of the air inside of the needle. This means the amount of “aspiration” of saline drop differs according to the distance of the needle tip reaches the epidural space through the ligament after advancing the needle. In this way, knowing that the degree of attraction of the saline droplet may change depending