基于灵敏度的配电系统可靠性指标评估方法。

G. Ajenikoko, O. J. Oyedele
{"title":"基于灵敏度的配电系统可靠性指标评估方法。","authors":"G. Ajenikoko, O. J. Oyedele","doi":"10.7176/apta/77-07","DOIUrl":null,"url":null,"abstract":"In Nigeria, satisfactory degree of reliability has not been attained in the power system in recent times. The average duration of interruptions that customers experience is very high and the degree varies widely especially in urban and commercial cities of the country. This research paper therefore presents the sensitivity analysis of electrical distribution systems. Ten years of outage information from seven major distribution systems – Ibadan, Ilorin, Ikeja, Portharcourt, Kaduna, Kano and Benin were used as input data for computation of the mean and standard deviation for the system reliability indices using statistical analysis. The computed system reliability indices were used as input parameters in the analysis. A sensitivity analysis is performed to assess how the operation parameters could influence the numerical results. The results of the sensitivity studies indicate that Etete feeder of  Benin distribution system has the highest SAIDI sensitivity of 0.5478 because of prolonged customers‘ interruptions on the feeder while waterworks feeder of Ilorin distribution system has the least SAIDI sensitivity of 0.0019. Cocoa feeder of Ibadan distribution system has the highest SAIFI sensitivity of 1.0459 because of the frequent interruptions while waterworks feeder of Ilorin distribution system has the least SAIFI sensitivity of 0.0268. Ikpoba Dam of Benin distribution system recorded the highest CAIDI sensitivity of 0.8466 with waterworks feeder also recording the least CAIDI sensitivity of 0.0075. The results from this research paper provides baseline information for planning and managing distribution system on Nigeria national grid. Keywords: Sensitivity, Reliability indices, Distribution systems, SAIDI, SAIFI, CAIDI, Interruptions. DOI : 10.7176/APTA/77-07 Publication date :May 31 st 2019","PeriodicalId":7386,"journal":{"name":"Advances in Physics Theories and Applications","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Sensitivity Based Approach for Assessment of Reliability Indices of Electrical Distribution Systems.\",\"authors\":\"G. Ajenikoko, O. J. Oyedele\",\"doi\":\"10.7176/apta/77-07\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In Nigeria, satisfactory degree of reliability has not been attained in the power system in recent times. The average duration of interruptions that customers experience is very high and the degree varies widely especially in urban and commercial cities of the country. This research paper therefore presents the sensitivity analysis of electrical distribution systems. Ten years of outage information from seven major distribution systems – Ibadan, Ilorin, Ikeja, Portharcourt, Kaduna, Kano and Benin were used as input data for computation of the mean and standard deviation for the system reliability indices using statistical analysis. The computed system reliability indices were used as input parameters in the analysis. A sensitivity analysis is performed to assess how the operation parameters could influence the numerical results. The results of the sensitivity studies indicate that Etete feeder of  Benin distribution system has the highest SAIDI sensitivity of 0.5478 because of prolonged customers‘ interruptions on the feeder while waterworks feeder of Ilorin distribution system has the least SAIDI sensitivity of 0.0019. Cocoa feeder of Ibadan distribution system has the highest SAIFI sensitivity of 1.0459 because of the frequent interruptions while waterworks feeder of Ilorin distribution system has the least SAIFI sensitivity of 0.0268. Ikpoba Dam of Benin distribution system recorded the highest CAIDI sensitivity of 0.8466 with waterworks feeder also recording the least CAIDI sensitivity of 0.0075. The results from this research paper provides baseline information for planning and managing distribution system on Nigeria national grid. Keywords: Sensitivity, Reliability indices, Distribution systems, SAIDI, SAIFI, CAIDI, Interruptions. DOI : 10.7176/APTA/77-07 Publication date :May 31 st 2019\",\"PeriodicalId\":7386,\"journal\":{\"name\":\"Advances in Physics Theories and Applications\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advances in Physics Theories and Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.7176/apta/77-07\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Physics Theories and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7176/apta/77-07","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在尼日利亚,近年来电力系统的可靠性一直没有达到令人满意的程度。客户经历的平均中断时间非常长,并且程度差异很大,特别是在该国的城市和商业城市。因此,本文提出了配电系统的灵敏度分析。七个主要配电系统(伊巴丹、伊洛林、Ikeja、Portharcourt、卡杜纳、卡诺和贝宁)10年的停电信息被用作输入数据,使用统计分析计算系统可靠性指数的平均值和标准差。计算得到的系统可靠性指标作为分析的输入参数。进行了灵敏度分析,以评估操作参数对数值结果的影响。灵敏度研究结果表明,由于用户对供水系统的长时间中断,贝宁配电系统埃特特供水系统的SAIDI灵敏度最高,为0.5478,而伊洛林配电系统自来水厂供水系统的SAIDI灵敏度最低,为0.0019。伊巴丹配电系统的可可给料机由于中断频繁,SAIFI灵敏度最高,为1.0459;伊洛林配电系统的自来水给料机SAIFI灵敏度最低,为0.0268。贝宁配电系统Ikpoba大坝的CAIDI灵敏度最高,为0.8466,自来水厂给水机的CAIDI灵敏度最低,为0.0075。本文的研究结果为尼日利亚国家电网配电系统的规划和管理提供了基础信息。关键词:灵敏度,可靠性指标,配电系统,SAIDI, SAIFI, CAIDI,中断。出版日期:2019年5月31日
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Sensitivity Based Approach for Assessment of Reliability Indices of Electrical Distribution Systems.
In Nigeria, satisfactory degree of reliability has not been attained in the power system in recent times. The average duration of interruptions that customers experience is very high and the degree varies widely especially in urban and commercial cities of the country. This research paper therefore presents the sensitivity analysis of electrical distribution systems. Ten years of outage information from seven major distribution systems – Ibadan, Ilorin, Ikeja, Portharcourt, Kaduna, Kano and Benin were used as input data for computation of the mean and standard deviation for the system reliability indices using statistical analysis. The computed system reliability indices were used as input parameters in the analysis. A sensitivity analysis is performed to assess how the operation parameters could influence the numerical results. The results of the sensitivity studies indicate that Etete feeder of  Benin distribution system has the highest SAIDI sensitivity of 0.5478 because of prolonged customers‘ interruptions on the feeder while waterworks feeder of Ilorin distribution system has the least SAIDI sensitivity of 0.0019. Cocoa feeder of Ibadan distribution system has the highest SAIFI sensitivity of 1.0459 because of the frequent interruptions while waterworks feeder of Ilorin distribution system has the least SAIFI sensitivity of 0.0268. Ikpoba Dam of Benin distribution system recorded the highest CAIDI sensitivity of 0.8466 with waterworks feeder also recording the least CAIDI sensitivity of 0.0075. The results from this research paper provides baseline information for planning and managing distribution system on Nigeria national grid. Keywords: Sensitivity, Reliability indices, Distribution systems, SAIDI, SAIFI, CAIDI, Interruptions. DOI : 10.7176/APTA/77-07 Publication date :May 31 st 2019
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信