{"title":"Sagnac干涉仪在散射超声场表征中的应用","authors":"P. Fomitchov, A. Kromine, S. Krishnaswamy, J. Achenbach","doi":"10.1109/ULTSYM.1997.663095","DOIUrl":null,"url":null,"abstract":"Knowledge of the spatial and temporal parameters of ultrasonic beams, as well as details of interaction of such beams with small defects is necessary for effective application of ultrasonic techniques to nondestructive evaluation (NDE). The work presented here employs a fiber-optic Sagnac interferometer to characterize acoustical fields generated by conventional piezoelectric transducers (PZT) and a laser ultrasonic source, and the scattering of such ultrasonic fields by flaws. The high spatial resolution of this interferometer and its ability to provide absolute ultrasonic displacements make this device very suitable for: (i) profiling and calibration of ultrasonic beams generated by PZT transducers or laser sources, and (ii) precision measurement of ultrasonic fields scattered by flaws.","PeriodicalId":6369,"journal":{"name":"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)","volume":"15 1","pages":"609-612 vol.1"},"PeriodicalIF":0.0000,"publicationDate":"1997-10-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Application of a Sagnac interferometer for the characterization of scattered ultrasonic fields\",\"authors\":\"P. Fomitchov, A. Kromine, S. Krishnaswamy, J. Achenbach\",\"doi\":\"10.1109/ULTSYM.1997.663095\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Knowledge of the spatial and temporal parameters of ultrasonic beams, as well as details of interaction of such beams with small defects is necessary for effective application of ultrasonic techniques to nondestructive evaluation (NDE). The work presented here employs a fiber-optic Sagnac interferometer to characterize acoustical fields generated by conventional piezoelectric transducers (PZT) and a laser ultrasonic source, and the scattering of such ultrasonic fields by flaws. The high spatial resolution of this interferometer and its ability to provide absolute ultrasonic displacements make this device very suitable for: (i) profiling and calibration of ultrasonic beams generated by PZT transducers or laser sources, and (ii) precision measurement of ultrasonic fields scattered by flaws.\",\"PeriodicalId\":6369,\"journal\":{\"name\":\"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)\",\"volume\":\"15 1\",\"pages\":\"609-612 vol.1\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-10-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.1997.663095\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.1997.663095","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

了解超声光束的时空参数,以及这些光束与小缺陷相互作用的细节是有效地将超声技术应用于无损评估(NDE)所必需的。本文采用光纤Sagnac干涉仪来表征由传统压电换能器(PZT)和激光超声源产生的声场,以及这种超声场在缺陷下的散射。该干涉仪的高空间分辨率及其提供绝对超声位移的能力使该设备非常适合:(i) PZT换能器或激光源产生的超声光束的分析和校准,以及(ii)由缺陷散射的超声场的精确测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Application of a Sagnac interferometer for the characterization of scattered ultrasonic fields
Knowledge of the spatial and temporal parameters of ultrasonic beams, as well as details of interaction of such beams with small defects is necessary for effective application of ultrasonic techniques to nondestructive evaluation (NDE). The work presented here employs a fiber-optic Sagnac interferometer to characterize acoustical fields generated by conventional piezoelectric transducers (PZT) and a laser ultrasonic source, and the scattering of such ultrasonic fields by flaws. The high spatial resolution of this interferometer and its ability to provide absolute ultrasonic displacements make this device very suitable for: (i) profiling and calibration of ultrasonic beams generated by PZT transducers or laser sources, and (ii) precision measurement of ultrasonic fields scattered by flaws.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信