Al2O3:C和LiF:Mg,Cu,P对自然本底辐射的热释光研究

Li Yongqiang, Chen Jingmin, Xiong Zhengye, W. Wenhua, T. Zhao, Shi Wenqing, Li Shiping
{"title":"Al2O3:C和LiF:Mg,Cu,P对自然本底辐射的热释光研究","authors":"Li Yongqiang, Chen Jingmin, Xiong Zhengye, W. Wenhua, T. Zhao, Shi Wenqing, Li Shiping","doi":"10.1109/ICBEB.2012.255","DOIUrl":null,"url":null,"abstract":"To choose the best thermo luminescent dosimeters (TLDs) for low radiation dose detector, thermo luminescence responses of three kinds of TLDs, Al<sub>2</sub>O<sub>3</sub>: C and LiF: Mg, Cu, P, were measured, and the natural background radiation in Zhanjiang is used as a low radiation field. The TLDs' sensitivities were compared, Al<sub>2</sub>O<sub>3</sub>:C (the threshold dose of is about 1-2μGy) is in some sort more sensitive than LiF:Mg, Cu, P (the threshold dose of is about 2μGy). Temperature of glow peak of Al<sub>2</sub>O<sub>3</sub>:C is not so high, and the TL would decay after a relatively long period, so the TL dose response curve of Al<sub>2</sub>O<sub>3</sub>:C is deviation from linearity. Temperatures of glow peaks of LiF:Mg, Cu, P are relatively high, and the TL would hardly decay after a relatively long period, so the TL dose response curves are nearly linearity. In a word, Al<sub>2</sub>O<sub>3</sub>:C is not the best TLD in low radiation cumulative dose detection, although it is the best optically stimulated luminescence dosimeter (OSLD).","PeriodicalId":6374,"journal":{"name":"2012 International Conference on Biomedical Engineering and Biotechnology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-05-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Investigation on Thermoluminescence of Al2O3:C and LiF:Mg,Cu,P to Natural Background Radiation\",\"authors\":\"Li Yongqiang, Chen Jingmin, Xiong Zhengye, W. Wenhua, T. Zhao, Shi Wenqing, Li Shiping\",\"doi\":\"10.1109/ICBEB.2012.255\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To choose the best thermo luminescent dosimeters (TLDs) for low radiation dose detector, thermo luminescence responses of three kinds of TLDs, Al<sub>2</sub>O<sub>3</sub>: C and LiF: Mg, Cu, P, were measured, and the natural background radiation in Zhanjiang is used as a low radiation field. The TLDs' sensitivities were compared, Al<sub>2</sub>O<sub>3</sub>:C (the threshold dose of is about 1-2μGy) is in some sort more sensitive than LiF:Mg, Cu, P (the threshold dose of is about 2μGy). Temperature of glow peak of Al<sub>2</sub>O<sub>3</sub>:C is not so high, and the TL would decay after a relatively long period, so the TL dose response curve of Al<sub>2</sub>O<sub>3</sub>:C is deviation from linearity. Temperatures of glow peaks of LiF:Mg, Cu, P are relatively high, and the TL would hardly decay after a relatively long period, so the TL dose response curves are nearly linearity. In a word, Al<sub>2</sub>O<sub>3</sub>:C is not the best TLD in low radiation cumulative dose detection, although it is the best optically stimulated luminescence dosimeter (OSLD).\",\"PeriodicalId\":6374,\"journal\":{\"name\":\"2012 International Conference on Biomedical Engineering and Biotechnology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-05-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 International Conference on Biomedical Engineering and Biotechnology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICBEB.2012.255\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Conference on Biomedical Engineering and Biotechnology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICBEB.2012.255","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

为了选择适合低辐射剂量检测器的热发光剂量计(TLDs),测量了Al2O3: C和LiF: Mg, Cu, P三种TLDs的热发光响应,并以湛江地区的自然本底辐射作为低辐射场。结果表明,Al2O3:C(阈值剂量约为1 ~ 2μGy)比LiF:Mg, Cu, P(阈值剂量约为2μGy)更敏感。Al2O3:C的发光峰温度不高,且经过较长时间后TL会衰减,因此Al2O3:C的TL剂量响应曲线偏离线性。LiF:Mg、Cu、P的发光峰温度较高,在较长的时间内TL几乎不会衰减,因此TL剂量响应曲线近似线性。综上所述,Al2O3:C虽然是最好的光激发发光剂量计(OSLD),但在低辐射累积剂量检测中并不是最好的TLD。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Investigation on Thermoluminescence of Al2O3:C and LiF:Mg,Cu,P to Natural Background Radiation
To choose the best thermo luminescent dosimeters (TLDs) for low radiation dose detector, thermo luminescence responses of three kinds of TLDs, Al2O3: C and LiF: Mg, Cu, P, were measured, and the natural background radiation in Zhanjiang is used as a low radiation field. The TLDs' sensitivities were compared, Al2O3:C (the threshold dose of is about 1-2μGy) is in some sort more sensitive than LiF:Mg, Cu, P (the threshold dose of is about 2μGy). Temperature of glow peak of Al2O3:C is not so high, and the TL would decay after a relatively long period, so the TL dose response curve of Al2O3:C is deviation from linearity. Temperatures of glow peaks of LiF:Mg, Cu, P are relatively high, and the TL would hardly decay after a relatively long period, so the TL dose response curves are nearly linearity. In a word, Al2O3:C is not the best TLD in low radiation cumulative dose detection, although it is the best optically stimulated luminescence dosimeter (OSLD).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信