{"title":"一种新型放疗计划人工智能自动分割工具的临床验证与定量评价","authors":"Peng Jl","doi":"10.47829/coo.2023.61301","DOIUrl":null,"url":null,"abstract":"higher than 0.90 for all OARs except the esophagus (mean DSC 0.83 ± 0.09)). Mean DSC values ranged from 0.98 ± 0.01 to 0.83 ± 0.09, while the DTAmean ranged from 0.68 ± 0.3 to 0.84 +0.54 mm to mm. HD values ranged from 9.88±15.99 mm to 25.61±8.78 mm. For all body sites, the AI-AS system was able to generate a full set of contours in approximately 2 minutes, while manual contouring of these structures required approximately 30 minutes.","PeriodicalId":92766,"journal":{"name":"Clinics of oncology","volume":"31 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Clinical Validation and Quantitative Evaluation of a Novel Artificial-Intelligence Automatic Segmentation Tool in Radiotherapy Planning\",\"authors\":\"Peng Jl\",\"doi\":\"10.47829/coo.2023.61301\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"higher than 0.90 for all OARs except the esophagus (mean DSC 0.83 ± 0.09)). Mean DSC values ranged from 0.98 ± 0.01 to 0.83 ± 0.09, while the DTAmean ranged from 0.68 ± 0.3 to 0.84 +0.54 mm to mm. HD values ranged from 9.88±15.99 mm to 25.61±8.78 mm. For all body sites, the AI-AS system was able to generate a full set of contours in approximately 2 minutes, while manual contouring of these structures required approximately 30 minutes.\",\"PeriodicalId\":92766,\"journal\":{\"name\":\"Clinics of oncology\",\"volume\":\"31 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinics of oncology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.47829/coo.2023.61301\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinics of oncology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47829/coo.2023.61301","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
除食道外,所有桨叶均高于0.90(平均DSC 0.83±0.09)。平均DSC值为0.98±0.01 ~ 0.83±0.09,DTAmean值为0.68±0.3 ~ 0.84 +0.54 mm ~ mm, HD值为9.88±15.99 mm ~ 25.61±8.78 mm。对于所有身体部位,AI-AS系统能够在大约2分钟内生成一整套轮廓,而这些结构的手动轮廓需要大约30分钟。
Clinical Validation and Quantitative Evaluation of a Novel Artificial-Intelligence Automatic Segmentation Tool in Radiotherapy Planning
higher than 0.90 for all OARs except the esophagus (mean DSC 0.83 ± 0.09)). Mean DSC values ranged from 0.98 ± 0.01 to 0.83 ± 0.09, while the DTAmean ranged from 0.68 ± 0.3 to 0.84 +0.54 mm to mm. HD values ranged from 9.88±15.99 mm to 25.61±8.78 mm. For all body sites, the AI-AS system was able to generate a full set of contours in approximately 2 minutes, while manual contouring of these structures required approximately 30 minutes.