考虑灵敏度分析的PMU最优放置

Chandrasekhar Yammani, Narsi Reddy K, Sydulu Maheswarapu
{"title":"考虑灵敏度分析的PMU最优放置","authors":"Chandrasekhar Yammani, Narsi Reddy K, Sydulu Maheswarapu","doi":"10.1109/TAPENERGY.2015.7229590","DOIUrl":null,"url":null,"abstract":"This paper presents various aspects of optimal Phasor measurement unit (PMU) placement problem with load sensitivity analysis. Binary integer linear programming based methodology for optimal placement of PMU in a given power network for full observability of that network is presented in this paper. First, complete observability of the given network is formulated conventionally and then, zero injection bus constraints are added in conventional formulation. Load sensitivity analysis is done using Newton-Rapson Load flow and most sensitive buses based on load sensitivity analysis, are sorted out. Minimum number of PMU's, less than the optimal number (without considering load sensitivity) are placed such that it covers most sensitive buses and also most of the buses are observed. In this paper optimal PMU placement problem considering sensitivity analysis is presented for IEEE-14 bus and IEEE-30 bus systems.","PeriodicalId":6552,"journal":{"name":"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)","volume":"27 1","pages":"40-44"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Optimal placement of PMU's considering sensitivity analysis\",\"authors\":\"Chandrasekhar Yammani, Narsi Reddy K, Sydulu Maheswarapu\",\"doi\":\"10.1109/TAPENERGY.2015.7229590\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents various aspects of optimal Phasor measurement unit (PMU) placement problem with load sensitivity analysis. Binary integer linear programming based methodology for optimal placement of PMU in a given power network for full observability of that network is presented in this paper. First, complete observability of the given network is formulated conventionally and then, zero injection bus constraints are added in conventional formulation. Load sensitivity analysis is done using Newton-Rapson Load flow and most sensitive buses based on load sensitivity analysis, are sorted out. Minimum number of PMU's, less than the optimal number (without considering load sensitivity) are placed such that it covers most sensitive buses and also most of the buses are observed. In this paper optimal PMU placement problem considering sensitivity analysis is presented for IEEE-14 bus and IEEE-30 bus systems.\",\"PeriodicalId\":6552,\"journal\":{\"name\":\"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)\",\"volume\":\"27 1\",\"pages\":\"40-44\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-06-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TAPENERGY.2015.7229590\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TAPENERGY.2015.7229590","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文介绍了带负载敏感性分析的最优相量测量单元(PMU)配置问题的各个方面。本文提出了一种基于二进制整数线性规划的电力网络中PMU的最优配置方法。首先对给定网络的完全可观测性进行常规表述,然后在常规表述中加入零注入总线约束。采用牛顿-拉普森法进行了负载敏感性分析,并在此基础上对最敏感的母线进行了分类。最小数量的PMU,小于最佳数量(不考虑负载灵敏度)被放置,这样它就覆盖了最敏感的总线,并且大多数总线都被观察到。本文针对IEEE-14总线和IEEE-30总线系统,提出了考虑灵敏度分析的PMU优化配置问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Optimal placement of PMU's considering sensitivity analysis
This paper presents various aspects of optimal Phasor measurement unit (PMU) placement problem with load sensitivity analysis. Binary integer linear programming based methodology for optimal placement of PMU in a given power network for full observability of that network is presented in this paper. First, complete observability of the given network is formulated conventionally and then, zero injection bus constraints are added in conventional formulation. Load sensitivity analysis is done using Newton-Rapson Load flow and most sensitive buses based on load sensitivity analysis, are sorted out. Minimum number of PMU's, less than the optimal number (without considering load sensitivity) are placed such that it covers most sensitive buses and also most of the buses are observed. In this paper optimal PMU placement problem considering sensitivity analysis is presented for IEEE-14 bus and IEEE-30 bus systems.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信